文献速递关节外科

运动学对线植入内侧稳定型与后稳定型全膝关节假体的结局比较:内侧稳定型更优

Outcomes are Better With a Medial-Stabilized vs a Posterior-Stabilized Total Knee Implanted With Kinematic Alignment.
PubMed 文献 · J Arthroplasty · 2022-02-18

这项前瞻性随机单中心1级研究比较了99例后稳定型(PS)与101例运动学对线植入内侧稳定型(MS)全膝关节假体的临床结局。所有受试者随访至少2年,MS组在1年和2年时的膝关节协会评分、遗忘关节评分和活动度均优于PS组,但PS组止血带时间较长。

要点

  • MS组2年遗忘关节评分为68.3,PS组为58.3(P=0.02),MS组更优。
  • MS组2年最大屈曲度为132°,PS组为124°(P<0.0001),MS组更优。
  • PS组止血带时间较MS组延长7.24%(40.28分钟 vs 37.56分钟,P<0.0086)。

核心结论

  • 运动学对线植入的MS组在1年和2年时的临床结局优于PS组,在至少2年随访时MS假体在多项临床结局上显示出优势。

研究设计与样本

  • 前瞻性、随机、单中心1级研究,比较99例接受PS假体与101例接受运动学对线植入MS假体的患者,已获机构审查委员会批准并取得知情同意。

主要发现

  • 所有受试者均达到至少2年随访,两组在人口学特征、术前评分或对线(术前或术后)方面无统计学显著差异。
  • PS组止血带时间为40.28分钟,MS组为37.56分钟,PS组较MS组延长7.24%(P<0.0086)。
  • 两组在1年和2年膝关节协会评分、遗忘关节评分和活动度方面存在显著差异,均有利于MS组。
  • 2年遗忘关节评分MS组为68.3,PS组为58.3(P=0.02)。
  • 2年最大屈曲度MS组为132°,PS组为124°(P<0.0001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: There is no consensus whether a posterior-stabilized (PS) total knee device is superior to a more congruent, cruciate-substituting, medial-stabilized device (MS). This study compared the clinical outcomes of these devices. The primary hypothesis was that the clinical outcomes would be better in the MS group implanted with kinematic alignment. METHODS: This prospective, randomized, single-center Level 1 study compared the outcomes of 99 patients who received a PS device and 101 patients who received an MS device implanted with kinematic alignment. Institutional Review Board approval and informed consent were obtained. Clinical and radiographic assessments were performed preoperatively, 6 weeks, 6 months, and annually. RESULTS: All subjects reached the minimum follow-up of 2 years. There were no statistically significant differences in demographic characteristics, preoperative scores, or alignment (preoperative or postoperative). Tourniquet time was 7.24% longer for the PS group (40.28 min vs 37.56 min, P < .0086). There were significant differences between groups for the 1-year and 2-year Knee Society scores, Forgotten Joint Score, and ROM; in every case favoring the MS group. The FJS was 68.3 in the MS group at 2 years and 58.3 in the PS group (P = .02). The maximum flexion at 2 years was 132° in the MS group and 124° in the PS group (P < .0001). CONCLUSION: The clinical outcomes of the MS group at 1 and 2 years were better. At the minimum 2-year follow-up, the results demonstrate the superiority of the medial-stabilized device in terms of multiple clinical outcomes. LEVEL OF EVIDENCE: I.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Scott DF, Gray CG. Outcomes are Better With a Medial-Stabilized vs a Posterior-Stabilized Total Knee Implanted With Kinematic Alignment. J Arthroplasty. 2022. PMID: 35189286. doi:10.1016/j.arth.2022.02.059