两中心89例感染髋关节置换股骨骨水泥-骨水泥翻修术
两中心采用股骨骨水泥-骨水泥翻修技术,对89例感染髋关节置换患者保留远端固定良好的骨水泥层,平均随访56.5个月,82例(92.1%)感染清除且假体固定成功,7例(7.9%)因感染再次翻修。
要点
- 保留固定良好的股骨骨水泥层行骨水泥-骨水泥翻修,89例中82例(92.1%)感染清除且假体固定成功。
- 7例(7.9%)因感染需再次翻修。
- 术后牛津髋关节评分提示功能结果满意。
核心结论
- 在感染情况下保留固定良好的股骨骨水泥层行骨水泥-骨水泥翻修,89例中82例(92.1%)在感染清除和假体固定两方面均获成功。
- 作者认为该结果与其他更具侵入性的技术相当,并为患者提供显著潜在获益。
研究设计与样本
- 两中心连续纳入89例因感染行股骨骨水泥-骨水泥翻修术的患者,包括单期和两期翻修的第一期。
- 采用该技术的前提是术者认为骨水泥层与骨紧密固定、其间无膜状组织。
- 存活病例随访平均56.5个月(范围24.0至134.7个月)。
主要发现
- 7例(7.9%)因感染需进一步翻修。
- 10例(平均5.9个月,范围0.9至18.6个月)在两年复查前死于与感染无关的原因。
- 1例术后5个月失访,2例在两年复查到期后不久死于与髋关节无关的原因且未参加复查。
- 其余患者中69例在末次复查时无感染。
- 影像学复查证实该手术的机械成功性与先前在无菌性翻修中描述的一致,术后牛津髋关节评分提示功能结果满意。
关键数值与推荐
- 89例中82例(92.1%)感染清除且假体固定成功。
- 7例(7.9%)因感染再次翻修。
临床怎么用
- 本研究中心的做法是,在选定患者中行感染髋关节翻修时采用骨水泥-骨水泥技术,保留远端股骨骨水泥,用于单期及两期翻修的第一期。
- 采用该技术的前提是术者认为骨水泥层与骨紧密固定、其间无膜状组织。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: Femoral cement-in-cement revision is a well described technique to reduce morbidity and complications in hip revision surgery. Traditional techniques for septic revision of hip arthroplasty necessitate removal of all bone cement from the femur. In our two centres, we have been using a cement-in-cement technique, leaving the distal femoral bone cement in selected patients for septic hip revision surgery, both for single and the first of two-stage revision procedures. A prerequisite for adoption of this technique is that the surgeon considers the cement mantle to be intimately fixed to bone without an intervening membrane between cement and host bone. We aim to report our experience for this technique. METHODS: We have analyzed patients undergoing this cement-in-cement technique for femoral revision in infection, and present a consecutive series of 89 patients. Follow-up was undertaken at a mean of 56.5 months (24.0 to 134.7) for the surviving cases. RESULTS: Seven patients (7.9%) required further revision for infection. Ten patients died of causes unrelated to their infection before their two-year review (mean 5.9 months; 0.9 to 18.6). One patient was lost to follow-up at five months after surgery, and two patients died of causes unrelated to their hip shortly after their two-year review was due without attending. Of the remaining patients, 69 remained infection-free at final review. Radiological review confirms the mechanical success of the procedure as previously described in aseptic revision, and postoperative Oxford Hip Scores suggest satisfactory functional outcomes. CONCLUSION: In conclusion, we found that retaining a well-fixed femoral cement mantle in the presence of infection and undertaking a cement-in-cement revision was successful in 82 of the patients (92.1%) in our series of 89, both in terms of eradication of infection and component fixation. These results are comparable to other more invasive techniques and offer significant potential benefits to the patient. Cite this article: Bone Joint J 2022;104-B(2):212-220.
引用
- Fishley WG, Selvaratnam V, Whitehouse SL, et al. Cement-in-cement revision of the femur in infected hip arthroplasty in 89 patients across two centres. Bone Joint J. 2022. PMID: 35094572. doi:10.1302/0301-620X.104B2.BJJ-2021-0598.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。