机器人辅助与传统全髋关节置换术后不稳定与髋臼杯位置的比较

Comparison of Postoperative Instability and Acetabular Cup Positioning in Robotic-Assisted Versus Traditional Total Hip Arthroplasty.
PubMed 文献 · J Arthroplasty · 2022-02-08

单医院三术者队列研究纳入2014年1月至2020年6月初次全髋关节置换2247例(手动全髋关节置换1724例、机器人辅助全髋关节置换523例),比较脱位率及相关翻修。机器人辅助组脱位率0.6%低于手动组2.5%(多因素比值比3.74,P<.046),机器人辅助组不稳定病例均保守治疗成功,而手动组46%因复发性不稳定接受翻修。两组患者报告结局与其他并发症无显著差异。

要点

  • 机器人辅助全髋关节置换脱位率0.6%,低于手动全髋关节置换的2.5%(多因素比值比3.74,P<.046)。
  • 机器人辅助组不稳定病例均保守治疗成功,手动组46%因复发性不稳定接受翻修。
  • 机器人辅助组髋臼杯前倾角更大、外倾角更小(P<.05),患者报告结局与其他并发症无显著差异。

核心结论

  • 机器人辅助全髋关节置换的脱位率不足手动全髋关节置换的四分之一,且无因不稳定而翻修的病例。
  • 机器人辅助全髋关节置换与患者报告结局或其他早期并发症无差异。
  • 机器人辅助全髋关节置换对稳定性的影响超出单纯髋臼杯位置,值得进一步研究。

研究设计与样本

  • 单医院三术者队列研究,纳入2014年1月至2020年6月接受初次全髋关节置换的2247例连续患者,其中手动全髋关节置换1724例、机器人辅助全髋关节置换523例。
  • 通过密歇根关节置换登记协作质量 initiative 收集人口学资料、患者报告结局、急诊就诊、再入院及90天并发症,病历回顾获取不稳定发生情况,平均随访4年。
  • 进行多因素回归分析,并评估368张X线片样本(包括所有脱位病例)。

主要发现

  • 机器人辅助全髋关节置换脱位率0.6%,手动全髋关节置换脱位率2.5%,多因素比值比3.74(P<.046)。
  • 机器人辅助全髋关节置换所有不稳定病例均保守治疗成功,手动全髋关节置换不稳定病例中46%因复发性不稳定接受翻修。
  • 机器人辅助组髋臼杯前倾角25.6°±5.4°大于手动组20.6°±7.6°,外倾角42.5°±5.3°小于手动组47.0°±6.7°(P<.05)。
  • 两组人口学资料、患者报告结局或其他并发症无显著差异(P>.05)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文结论指出机器人辅助全髋关节置换对稳定性的影响超出单纯髋臼杯位置,值得进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Robotic-assisted total hip arthroplasty (R-THA) affords precision yet uncertain clinical benefits. This study compares dislocation rates and related revisions between R-THA and manual total hip arthroplasty (M-THA). Secondarily we evaluated cup position, patient-reported outcome measures (PROMs), and postoperative complications. METHODS: A three-surgeon cohort study was conducted on 2247 consecutive patients (1724 M-THA and 523 R-THA) who received a primary THA between January 2014 and June 2020 at a single hospital. Demographics, PROMs, emergency department visits, readmissions, and 90-day complications were collected via the Michigan Arthroplasty Registry Collaborative Quality Initiative. Chart review yielded instability occurrence with an average follow-up of 4 years. Multivariate regression analysis was performed, and a sample of 368 radiographs, including all dislocations, were assessed. RESULTS: There were significantly lower rates of dislocation in R-THA (0.6%) vs M-THA (2.5%; Multivariate odds ratio 3.74, P < .046). All cases of unstable R-THA were successfully treated conservatively, whereas 46% of unstable M-THA were revised for recurrent instability. Cup anteversion (25.6° ± 5.4° R-THA vs 20.6° ± 7.6° M-THA) was greater, and cup inclination (42.5° ± 5.3° R-THA vs 47.0° ± 6.7° M-THA) was lower in the R-THA group (P < .05). No significant differences were noted for demographics, PROMs, or other complications (P > .05). CONCLUSION: R-THA resulted in less than one-fourth the dislocation rate compared to M-THA and no revision for instability. It was associated with no difference in PROMs or other early complications. The influence of R-THA on stability goes beyond simply cup positioning and deserves further study.