初次与翻修全膝关节置换术手术室空气质量比较
本研究在学术机构单一手术室分析2020年1月至12月初次与翻修全膝关节置换术(TKA)术中空气颗粒物(ABP)计数,排除2020年3月15日至5月4日新冠相关混杂病例。共纳入107例(初次79例、翻修28例),翻修TKA手术室停留时间及0.3、0.5、1.0、2.5微米颗粒和PM2.5、PM5.0速率均显著高于初次TKA,作者认为需进一步研究颗粒大小与数量是否转化为翻修TKA后更高的感染率。
要点
- 翻修TKA手术室停留时间显著长于初次TKA(220±47.1分钟 vs 176±46.7分钟,P<.0001)。
- 翻修TKA的0.3微米(+70.4%,P<.001)、0.5微米(+97.2%,P<.0001)、1.0微米(+53.2%,P=.001)和2.5微米(+30.3%,P=.017)颗粒速率显著高于初次TKA。
- 翻修TKA的PM2.5(+108.3%,P<.001)和PM5.0(+105.6%,P<.001)速率显著高于初次TKA。
核心结论
- 翻修TKA手术室停留时间显著更长,且0.3、0.5、1.0微米颗粒及PM2.5、PM5.0速率显著高于初次TKA。
- 需进一步研究以确定ABP的大小和数量是否转化为翻修TKA后更高的感染率。
研究设计与样本
- 单中心学术机构单一手术室分析2020年1月至12月初次与翻修TKA,排除2020年3月15日至5月4日病例以避免新冠相关混杂。
- 术中采用粒子计数器记录温度、湿度和每分钟ABP计数,并与电子健康记录手术数据交叉核对。
- 采用描述性统计、t检验和卡方检验比较变量差异。
主要发现
- 共纳入107例TKA:初次79例(73.8%)、翻修28例(26.2%)。
- 翻修TKA手术室停留时间显著高于初次(220±47.1分钟 vs 176±46.7分钟,P<.0001)。
- 翻修TKA较初次TKA的ABP速率显著升高:0.3微米+70.4%(P<.001)、0.5微米+97.2%(P<.0001)、1.0微米+53.2%(P=.001)、2.5微米+30.3%(P=.017)。
- 翻修TKA较初次TKA的PM2.5速率升高108.3%(P<.001)、PM5.0速率升高105.6%(P<.001)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 需进一步研究以确定ABP的大小和数量是否转化为翻修TKA后更高的感染率。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Airborne biologic particles (ABPs) can be measured intraoperatively to evaluate operating room (OR) sterility. Particulate matter (PM) up to 2.5 microns can contain microbial species which may increase infection risk. Our study examines the differences in air quality and ABP count in primary total knee arthroplasty (TKA) and revision TKA (rTKA). METHODS: We analyzed primary and rTKAs in a single OR at an academic institution from January 2020 to December 2020. Procedures from March 15, 2020, to May 4, 2020, were excluded to avoid COVID-related confounding. Temperature, humidity, and ABP count per minute were recorded with a particle counter intraoperatively and cross-referenced with surgical data from the electronic health records using procedure start and end times. Descriptive statistics were used to evaluate the differences in variables. P values were calculated using t-test and chi-square test. RESULTS: A total of 107 TKA cases were included: 79 (73.8%) primary TKAs and 28 (26.2%) rTKAs. Time spent in an OR was significantly higher for rTKAs (primary: 176 ± 46.7 minutes vs revision: 220 ± 47.1 minutes, P < .0001). Compared to primary TKAs, rTKAs had significant percent increases in ABP rates for particles measuring 0.3 μm (+70.4%, P < .001), 0.5 μm (+97.2%, P < .0001), 1.0 μm (+53.2%, P = .001), and 2.5 μm (+30.3%, P = .017) and for PM 2.5 (+108.3%, P < .001) and PM 5.0 (+105.6%, P < .001). CONCLUSION: rTKAs had significantly longer time spent in an OR and significant percent increases in ABP rates for particles measuring 0.3 μm, 0.5 μm, and 1.0 μm compared to primary TKAs. Measurements of PM 2.5 and 5.0 (which can contain large numbers of microbes) were also significantly greater in rTKAs. Further research is needed to determine whether the size and quantity of ABPs translate to higher infection rates after rTKA.
引用
- Sicat CS, Schwarzkopf R, Slover JD, et al. Comparison of Operating Room Air Quality in Primary Versus Revision Total Knee Arthroplasty. J Arthroplasty. 2022. PMID: 35202754. doi:10.1016/j.arth.2022.02.049
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。