凝固酶阴性葡萄球菌假体膝关节感染:预后不良的先兆
该回顾性队列研究纳入2009至2020年单中心55例全膝关节置换术后培养证实的凝固酶阴性葡萄球菌假体周围感染成人患者,平均随访29.8个月。最常见病原体为表皮葡萄球菌(n=36,65.5%),甲氧西林耐药率63%。术后一年仅47%患者感染治疗成功,清创保留假体组失败率60.0%高于二期翻修组46.7%。
要点
- 凝固酶阴性葡萄球菌假体周围感染术后一年治疗成功率仅47%。
- 表皮葡萄球菌占65.5%(n=36),甲氧西林耐药率63%。
- 清创保留假体失败率60.0%,高于二期翻修的46.7%。
核心结论
- 凝固酶阴性葡萄球菌假体周围感染的治疗成功率低,可能反映生物膜形成所致的固有毒力与抗生素疗效下降之间的相互作用。
研究设计与样本
- 回顾性队列研究,纳入2009至2020年单中心三级医疗中心全膝关节置换术后培养证实的凝固酶阴性葡萄球菌假体周围感染成人患者55例,诊断依据肌肉骨骼感染学会标准,平均随访29.8个月(标准差16.3个月)。
主要发现
- 最常见分离病原体为表皮葡萄球菌(n=36,65.5%),甲氧西林耐药总体患病率为63%。
- 手术治疗包括清创联合抗生素及假体保留25例(45.5%)和二期翻修(22例活动型及8例静态抗生素浸渍间隔器)。
- 术后一年随访仅47%患者感染得到成功处理。
- 清创联合抗生素及假体保留组治疗失败率为60.0%,二期翻修组为46.7%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Coagulase-negative staphylococci (CoNS) are biofilm-producing pathogens whose role in periprosthetic joint infection (PJI) is increasing. There is little data on the prognosis and treatment considerations in the setting of PJI. We sought to evaluate the clinical characteristics, outcomes, and complications in these patients. METHODS: This is a retrospective cohort study of adult patients at a single tertiary medical center from 2009 to 2020 with culture-proven CoNS PJI after total knee arthroplasty, as diagnosed by Musculoskeletal Infection Society criteria. The primary outcome was treatment success, with failure defined as recurrent CoNS PJI, recurrent PJI with a new pathogen, and/or chronic oral antibiotic suppression at one year postoperatively. RESULTS: We identified 55 patients with a CoNS total knee arthroplasty PJI with a mean follow-up of 29.8 months (SD: 16.3 months). The most commonly isolated organism was Staphylococcus epidermidis (n = 36, 65.5%). The overall prevalence of methicillin resistance was 63%. Surgical treatment included surgical debridement, antibiotics, and implant retention in 25 (45.5%) cases and two-stage revision (22 articulating and eight static antibiotic-impregnated spacers). At one-year follow-up, only 47% of patients had successful management of their infection. The surgical debridement, antibiotics, and implant retention cohort had the higher rate of treatment failure (60.0%) compared to two-stage revision (46.7%). CONCLUSION: These results indicate a poor rate of success in treating CoNS PJI. This likely represents the interplay of inherent virulence through biofilm formation and decreased antibiotic efficacy.
引用
- Charalambous LT, Kim BI, Schwartz AM, et al. Prosthetic Knee Infection With Coagulase-Negative Staphylococcus: A Harbinger of Poor Outcomes. J Arthroplasty. 2022. PMID: 35196567. doi:10.1016/j.arth.2022.02.050
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。