压配式双枢轴全膝关节置换术:最少2年随访的早期结果

Press-Fit Dual-Pivot Total Knee Arthroplasty: Early Results With a Minimum 2-Year Follow-Up.
PubMed 文献 · J Arthroplasty · 2022-02-20

研究纳入2017至2019年连续232例采用压配式胫骨与股骨组件及超形合双枢轴胫骨垫片的全膝关节置换术,平均年龄56岁,最少随访2年(范围24-42个月)。末次随访无患者膝关节僵硬超过轻度,3膝(1.3%)翻修,未发现其他股骨或胫骨组件松动,作者认为该双枢轴设计在早期随访中未影响组件固定,临床与影像学结果可接受。

要点

  • 232例压配式双枢轴全膝关节置换术最少随访2年,平均年龄56岁。
  • 3膝(1.3%)翻修,分别因屈曲不稳、胫骨平台骨折和疑似股骨组件松动。
  • 未发现其他股骨或胫骨组件松动的病例。

核心结论

  • 作者认为,尽管非骨水泥全膝关节置换术的成功取决于多种因素,但该双枢轴膝关节设计在早期随访中似乎未影响胫骨或股骨组件固定,获得了可接受的临床与影像学结果。

研究设计与样本

  • 2017年至2019年间连续植入232例全膝关节置换术,使用压配式胫骨与股骨组件及超形合双枢轴胫骨垫片,62%患者为男性,平均年龄56岁,最少随访2年(范围24-42个月),采用KOOS-JR与膝关节学会临床及影像学评估。

主要发现

  • 末次随访无患者膝关节僵硬超过轻度。
  • 2例患者报告爬楼梯时中度膝痛,其余患者报告活动时轻度或无疼痛。
  • 膝关节学会疼痛评分平均42分,屈曲度平均118度。
  • 3膝(1.3%)翻修,分别因屈曲不稳、胫骨平台骨折和疑似股骨组件松动。
  • 未发现其他股骨或胫骨组件松动的病例。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Ultracongruent (UC) tibial bearings are being used with increasing frequency in the United States. Evidence suggests that the use of certain UC bearings may lead to improved patient satisfaction when compared with using conventional inserts. However, little is known as to what effect the use of UC tibial inserts has on bone ingrowth in uncemented total knee arthroplasty (TKA). The purpose of this study was to determine the early clinical and radiographic results of TKA using a press-fit dual-pivot design. METHODS: Between 2017 and 2019, a consecutive series of 232 TKAs were implanted using a press-fit tibial and femoral component and a UC dual-pivot tibial insert. Sixty-two percent of patients were male. The average age was 56 years. Patients were followed for a minimum of 2 years (range, 24-42 months) using KOOS-JR and Knee Society clinical and radiographic evaluation. RESULTS: No patient had more than mild knee stiffness at the final follow-up. Two patients reported moderate knee pain with stair climbing. All other patients reported either mild or no pain with activity. Knee Society pain scores averaged 42 points. Flexion averaged 118 degrees. Three knees (1.3%) were revised (one each for flexion instability, tibial plateau fracture, and suspected femoral component loosening). No other cases of femoral or tibial loosening were identified. CONCLUSION: Although the success of uncemented TKA is determined by a variety of factors, the use of this dual-pivot knee design did not appear to influence tibial or femoral component fixation at early follow-up, yielding acceptable clinical and radiographic outcomes.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Meding JB, Meding LK, Meneghini RM, et al. Press-Fit Dual-Pivot Total Knee Arthroplasty: Early Results With a Minimum 2-Year Follow-Up. J Arthroplasty. 2022. PMID: 35197199. doi:10.1016/j.arth.2022.01.038

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。