现役军人合并型肩关节不稳行270°盂唇修复的中期结局:一项回顾性研究
该回顾性病例系列纳入2011年1月至2019年1月接受270°盂唇修复的52例现役军人合并型肩关节不稳患者,平均随访78.21个月。术后美国肩肘外科医师评分、单次评估数值评价评分和Rowe不稳评分均较术前显著提高,疼痛显著减轻,92.31%恢复现役;活动度无显著变化。
要点
- 现役军人合并型肩关节不稳行270°盂唇修复后中期患者报告结局评分显著改善。
- 术后疼痛视觉模拟评分显著下降,前屈、外旋和内旋活动度无显著变化。
- 术后恢复现役比例为92.31%,优势侧与非优势侧及不同锚钉类型间结局无显著差异。
核心结论
- 现役军人合并型肩关节不稳行270°盂唇修复的中期结局显示患者报告结局评分有统计学和临床显著改善,疼痛显著减轻,恢复现役比例为92.31%。
研究设计与样本
- 回顾性病例系列,证据等级4级;纳入2011年1月至2019年1月由资深术者连续行270°盂唇修复且结局评分完整的患者。
- 共52例符合纳入标准,均为手术时现役军人;所有患者均为创伤性事件后肩关节脱位,磁共振成像和术中表现符合合并型不稳。
主要发现
- 平均随访78.21个月(范围24至117个月)。
- 美国肩肘外科医师评分从术前44.92升至术后89.31(P < .0001),单次评估数值评价评分从52.32升至93.17(P < .0001),Rowe不稳评分从46.63升至91.35(P < .0001)。
- 疼痛视觉模拟评分从8.04降至1.44(P < .0001)。
- 前屈活动度从155.29°至155.96°(P = .6793)、外旋从67.50°至65.29°(P = .0623)、内旋从T9.58至T9.56(P = .9650),术后均无显著变化。
- 优势侧与非优势侧手术患者结局无显著差异,生物复合锚钉与全缝线锚钉间结局亦无显著差异;总体恢复现役比例为92.31%。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: There is a high prevalence of combined shoulder instability in military patients. Short-term outcomes after 270° labral repair are promising; however, there is a paucity of longer term outcome data in this high-demand group of patients. PURPOSE: To report the midterm outcomes of active-duty military patients treated with 270° labral repair for combined shoulder instability. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: All consecutive patients between January 2011 and January 2019 who underwent 270° labral repair by the senior surgeon with complete outcome scores were identified. All patients had experienced a shoulder dislocation after a traumatic event and had magnetic resonance imaging and intraoperative findings consistent with combined-type instability. A total of 52 patients met the inclusion criteria for the study, and all were active-duty servicemembers at the time of surgery. RESULTS: The mean follow-up was 78.21 months (range, 24-117 months). There was a statistically significant increase in the mean American Shoulder and Elbow Surgeons score (from 44.92 to 89.31; P < .0001), Single Assessment Numeric Evaluation score (from 52.32 to 93.17; P < .0001), and Rowe instability score (from 46.63 to 91.35; P < .0001) from preoperatively to postoperatively. Mean pain decreased significantly as measured by the visual analog scale for pain (from 8.04 to 1.44; P < .0001). Range of motion in forward flexion (from 155.29° to 155.96°; P = .6793), external rotation (from 67.50° to 65.29°; P = .0623), and internal rotation (from T9.58 to T9.56; P = .9650) did not change significantly postoperatively. Outcomes did not differ significantly for patients who underwent surgery on their dominant shoulder versus those who underwent surgery on their nondominant shoulder, nor did outcomes vary with the type of anchor utilized (biocomposite vs all-suture). The overall rate of return to active duty was 92.31%. CONCLUSION: Midterm outcomes in this population of active-duty patients undergoing 270° labral repair for combined shoulder instability demonstrated a statistically and clinically significant improvement in patient-reported outcome scores, a significant decrease in pain, and an overall rate of return to active duty of 92.31%.
引用
- Scanaliato JP, Dunn JC, Fares AB, et al. Outcomes of 270° Labral Repair for Combined Shoulder Instability in Active-Duty Military Patients: A Retrospective Study. Am J Sports Med. 2021. PMID: 34898288. doi:10.1177/03635465211061602
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。