超声定位与触诊定位股骨外上髁在前外侧韧带移植物股骨端定位中的比较

Femoral Positioning of the Anterolateral Ligament Graft With and Without Ultrasound Location of the Lateral Epicondyle.
PubMed 文献 · Am J Sports Med · 2021-11-30

该队列研究纳入2019年6月至12月接受初次联合前交叉韧带(ACL)与前外侧韧带(ALL)重建的120例患者,触诊组(n=60)与超声组(n=60)分别以触诊和术前超声定位股骨外上髁。超声组60例(100%)移植物均位于外上髁后上10 mm象限,触诊组为52例(87%)(P=0.006),结论认为超声引导下ALL移植物股骨端定位较单纯触诊更具可重复性。

要点

  • 超声组60例(100%)ALL移植物位于外上髁后上10 mm象限,触诊组为52例(87%)(P=0.006)。
  • 触诊组移植物定位误差在超重(BMI>25)与非超重患者中均出现(P=0.3)。
  • 超声引导下股骨端定位较单纯触诊更具可重复性,且不受BMI影响。

核心结论

  • 超声引导下将ALL移植物股骨端定位于股骨外上髁后上方,较单纯触诊更具可重复性,且不受BMI影响。

研究设计与样本

  • 队列研究,证据等级2级,纳入2019年6月至12月接受初次联合ACL与ALL重建的120例患者。
  • 触诊组(n=60)以触诊确定股骨外上髁位置,超声组(n=60)以术前超声引导确定。
  • 两组在年龄、性别、体重指数(BMI)和手术侧别方面具有可比性。
  • 股骨ALL移植物的计划定位为股骨外上髁的后方和近端,术后侧位X线片评估实际定位。
  • 主要结局为移植物位于股骨外上髁后上10 mm象限内,结果按BMI分为2个亚组分析。

主要发现

  • 超声组全部60例(100%)前外侧移植物位于股骨外上髁后上10 mm象限内。
  • 触诊组52例(87%)移植物位于股骨外上髁后上10 mm象限内(P=0.006)。
  • 触诊组移植物定位误差在超重(BMI>25)与非超重患者中均出现(P=0.3)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: In anterior cruciate ligament (ACL) reconstruction with anterolateral ligament (ALL) reconstruction, precise positioning of the ALL graft on the femur and tibia is key to achieve rotational control. The lateral femoral epicondyle is often used as a reference point for positioning of the ALL graft and can be located by palpation or with ultrasound guidance. PURPOSE: To compare the ALL graft positioning on the femoral side between an ultrasound-guided technique and a palpation technique for the location of the lateral epicondyle. STUDY DESIGN: Cohort study; Level of evidence, 2. METHODS: A total of 120 patients receiving a primary combined ACL and ALL reconstruction between June and December 2019 were included. The location of the lateral epicondyle was determined by palpation in the palpation group (n = 60) and with preoperative ultrasound guidance in the ultrasound group (n = 60). Groups were comparable in age, sex, body mass index (BMI), and operated side. The planned positioning of the femoral ALL graft was proximal and posterior to the lateral epicondyle. The effective positioning of the femoral ALL graft was evaluated on postoperative lateral radiographs. The primary outcome was location of the graft in a 10-mm quadrant posterior and proximal to the lateral epicondyle. Results were analyzed in 2 subgroups according to BMI. RESULTS: All 60 anterolateral grafts (100%) in the ultrasound group were positioned in a 10-mm quadrant posterior and proximal to the lateral epicondyle, as opposed to 52 (87%) in the palpation group (P = .006). Errors in graft positioning with palpation occurred in overweight patients (BMI >25) as well as nonoverweight patients (P = .3). CONCLUSION: Femoral positioning of the ALL graft posterior and proximal to the lateral epicondyle is more reproducible with ultrasound guidance when compared with palpation alone, regardless of BMI.