文献速递关节外科

滑液检测在排除全膝关节置换和全髋关节置换感染方面优于血清标志物:一项系统综述与Meta分析

Synovial-Based Tests Outperform Serum Markers to Rule Out Infection in Total Knee Arthroplasty and Total Hip Arthroplasty: A Systematic Review and Meta-Analysis.
PubMed 文献 · J Arthroplasty · 2021-12-21

该系统综述与Meta分析纳入24项研究共2974例需翻修的全膝关节或全髋关节置换患者,仅采用肌肉骨骼感染学会标准诊断假体周围感染。对7种诊断试验进行Meta分析,α-防御素 pooled 敏感度86%、特异度96.6%,滑液α-防御素和白细胞计数阴性预测值最高。作者建议在假体周围感染低-中 prevalence 的临床场景中,翻修术前进行关节穿刺并检测α-防御素和/或白细胞计数以排除感染。

要点

  • α-防御素 pooled 敏感度86%、特异度96.6%,为所分析试验中最高。
  • 滑液α-防御素和白细胞计数的阴性预测值最高。
  • 作者建议在低-中 prevalence 场景翻修术前用关节液α-防御素和/或白细胞计数排除感染。

核心结论

  • 作者建议在假体周围感染低-中 prevalence 的临床环境中,翻修全膝关节置换和翻修全髋关节置换术前进行关节穿刺,使用关节液α-防御素和/或白细胞计数排除假体周围感染。

研究设计与样本

  • 系统综述与Meta分析,检索EMBASE、MEDLINE、PubMed和Cochrane数据库。
  • 纳入仅使用肌肉骨骼感染学会标准诊断假体周围感染、涉及需翻修的全膝关节置换和全髋关节置换失败患者的研究。
  • 共纳入24项研究,描述2974例患者,质量评分范围为13至19(MINORS标准)。
  • 对7种独特诊断试验进行Meta分析,采用双变量模型计算诊断准确性合并估计并绘制汇总受试者工作特征曲线,在给定疾病 prevalence 的假设样本中计算阳性和阴性预测值。

主要发现

  • α-防御素显示最高的 pooled 敏感度和特异度,分别为86%和96.6%。
  • 滑液α-防御素和白细胞计数显示最高的阴性预测值。

关键数值与推荐

  • α-防御素 pooled 敏感度86%、特异度96.6%。
  • 滑液α-防御素和白细胞计数的阴性预测值最高。

临床怎么用

  • 作者建议在假体周围感染低-中 prevalence 的临床环境中,翻修全膝关节置换和翻修全髋关节置换术前进行关节穿刺,使用关节液α-防御素和/或白细胞计数排除假体周围感染。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Total knee arthroplasty (TKA) provides successful results in most patients. Periprosthetic joint infection (PJI) accounts for up to 25% of failed TKAs needing revision. In clinical practice, consensus in diagnostic strategy for excluding or diagnosing PJI is still lacking. In this systematic review and meta-analysis, we aim to provide a simplified data-driven diagnostic strategy for aseptic knee and hip revision surgeons to rule out PJI in the outpatient clinic phase. METHODS: A literature search in EMBASE, MEDLINE, PubMed, and Cochrane was conducted. Studies involving the diagnosis of PJI in patients with failed TKAs and total hip arthroplasties needing revision were identified. Only studies using the Musculoskeletal Infection Society criteria were included. Quality was assessed using MINORS criteria. Meta-analysis was performed for each diagnostic test identified in the included studies. Pooled estimates of diagnostic accuracy measures were calculated using a bivariate model and plotted in summary receiver-operator characteristic curves. Positive and negative predictive values were calculated in a hypothetical sample of patients with a given disease prevalence. RESULTS: Twenty-four studies met the inclusion criteria, describing a total of 2974 patients. Quality scores ranged from 13 to 19. Meta-analysis could be performed on 7 unique diagnostic tests. Highest pooled sensitivity and specificity were demonstrated for α-defensin with values of 86% and 96.6%, respectively. α-defensin and white blood cell count in synovial fluid demonstrate highest negative predictive value values. CONCLUSIONS: We recommend, in a clinical setting with low-intermediate prevalence of PJI, performing arthrocentesis and joint fluid analysis using α-defensin and/or white blood cell count before revision TKA and revision total hip arthroplasty surgery to rule out PJI.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Goud A, Nützinger D, van der Bij A, et al. Synovial-Based Tests Outperform Serum Markers to Rule Out Infection in Total Knee Arthroplasty and Total Hip Arthroplasty: A Systematic Review and Meta-Analysis. J Arthroplasty. 2021. PMID: 34952165. doi:10.1016/j.arth.2021.12.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。