长节段固定腰椎融合术中手术架选择与术中体位是否与成人脊柱畸形的影像学和临床结局相关
该回顾性研究纳入129例成人脊柱畸形患者中符合标准的60例,比较Wilson架与四柱架在多节段腰椎融合中的失血量、输血量、矢状面矫正及临床评分。四柱架组失血和输血更少、腰椎前凸和矢状面垂直轴恢复更优、达到理想矫正比例更高,而患者报告结局和并发症无差异。
要点
- 四柱架组失血量2019±1213 mL vs 1171±875 mL,Wilson架组更多。
- 四柱架组达到理想矫正比例术后即刻50% vs 21%,2年43% vs 12%。
- 两组Numeric Rating Scale和Oswestry Disability Index评分及并发症无临床重要差异。
核心结论
- 作者认为四柱架似乎有利于脊柱畸形的长节段融合,理想体位应降低腹内压、腹部自由下垂并减少髋屈曲以诱导前凸。
- 未来研究需将分析扩展到不同类型脊柱畸形,并用超过2年的随访验证影像学和临床结局。
研究设计与样本
- 回顾性分析2015年至2018年间651例胸腰椎固定融合患者中129例因成人脊柱畸形接受超过4个节段初次融合者,最终60例纳入分析。
- 2017年1月前一位术者仅使用Wilson架,2017年1月起同一术者持续使用四柱架;Wilson架组40例中34例(85%)随访至少2年(平均44±13个月),四柱架组32例中28例(88%)随访至少2年(平均34±6个月)。
- 两组年龄、性别、BMI、畸形类型和融合节段数无差异;采用重复测量方差分析比较影像学结局。
主要发现
- Wilson架组失血量2019±1213 mL vs 四柱架组1171±875 mL,平均差848 mL(95%CI 297至1399),p=0.003。
- Wilson架组输血总量1706±1003 mL vs 四柱架组911±651 mL,平均差795 mL(95%CI 353至1237),p=0.001。
- Wilson架组腰椎前凸恢复7°±10° vs 四柱架组18°±14°,平均差-11°(95%CI -17°至-5°),p<0.001;矢状面垂直轴Wilson架组-22±31 mm vs 四柱架组-43±27 mm,平均差21 mm(95%CI 5至36),p=0.009;差异持续至2年随访。
- 达到理想矫正比例四柱架组术后即刻50% vs Wilson架组21%(OR 3.9,95%CI 1.3至11.7,p=0.02),2年时43% vs 12%(OR 5.6,95%CI 1.6至20.3,p=0.005)。
- 两组术后Numeric Rating Scale和Oswestry Disability Index评分无临床重要差异,2年随访并发症无差异。
关键数值与推荐
- Numeric Rating Scale背痛和腿痛评分范围0-10,最小临床重要差异(MCID)均为2.9;Oswestry Disability Index评分范围0-100,MCID为15.4。
- 输血决策基于术中血红蛋白值,该方案在两组间同等应用。
临床怎么用
- 作者认为四柱架似乎有利于脊柱畸形的长节段融合。
- 作者指出理想的手术体位应降低腹内压、使腹部自由下垂并减少髋屈曲以诱导前凸。
局限性
- 未来研究需将分析扩展到不同类型脊柱畸形,并用超过2年的随访验证影像学和临床结局。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Previous studies of patient positioning during spinal surgery evaluated intraoperative or immediate postoperative outcomes after short-instrumented lumbar fusion. However, patient positioning during long-instrumented fusion for an adult spinal deformity (ASD) might be associated with differences in intraoperative parameters such as blood loss and longer-term outcomes such as spine alignment, and comparing types of surgical tables in the context of these larger procedures and evaluating longer-term outcome scores seem important. QUESTIONS/PURPOSES: (1) Do blood loss and the number of transfusions differ between patients who underwent multi-level spinal fusion with a Wilson frame and those with a four-poster frame? (2) Does restoration of lumbar lordosis and the sagittal vertical axis differ between patients who underwent surgery with the use of one frame or the other? (3) Do clinical outcomes as determined by Numeric Rating Scale and Oswestry Disability Index scores differ between the two groups of patients? (4) Are there differences in postoperative complications between the two groups? METHODS: Among 651 patients undergoing thoracolumbar instrumented fusion between 2015 and 2018, 129 patients treated with more than four levels of initial fusion for an ASD were identified. A total of 48% (62 of 129) were eligible; 44% (57 of 129) were excluded because of a history of fusion, three-column osteotomy, or surgical indications other than degenerative deformity, and another 8% (10 of 129) were lost before the minimum 2-year follow-up period. Before January 2017, one surgeon in this study used only a Wilson frame; starting in January 2017, the same surgeon consistently used a four-poster frame. Forty patients had spinal fusion using the Wilson frame; 85% (34 of 40) of these had follow-up at least 2 years postoperatively (mean 44 ± 13 months). Thirty-two patients underwent surgery using the four-poster frame; 88% (28 of 32) of these were available for follow-up at least 2 years later (mean 34 ± 6 months). The groups did not differ in terms of age, gender, BMI, type of deformity, or number of fused levels. Surgical parameters such as blood loss and the total amount of blood transfused were compared between the two groups. Estimated blood loss was measured by the amount of suction drainage and the amount of blood that soaked gauze. The decision to transfuse blood was based on intraoperative hemoglobin values, a protocol that was applied equally to both groups. Radiologic outcomes including sagittal parameters and clinical outcomes such as the Numerical Rating Scale score for back pain (range 0-10; minimal clinically important difference [MCID] 2.9) and leg pain (range 0-10; MCID 2.9) as well as the Oswestry Disability Index score (range 0-100; MCID 15.4) were also assessed through a longitudinally maintained database by two spine surgeons who participated in this study. Repeated-measures analysis of variance was used to compare selected radiologic outcomes between the two groups over time. RESULTS: Blood loss and the total amount of transfused blood were greater in the Wilson frame group than in the four-poster frame group (2019 ± 1213 mL versus 1171 ± 875 mL; mean difference 848 [95% CI 297 to 1399]; p = 0.003 for blood loss; 1706 ± 1003 mL versus 911 ± 651 mL; mean difference 795 [95% CI 353 to 1237]; p = 0.001 for transfusion). Lumbar lordosis and the sagittal vertical axis were less restored in the Wilson frame group than in the four-poster frame group (7° ± 10° versus 18° ± 14°; mean difference -11° [95% -17° to -5°]; p < 0.001 for lumbar lordosis; -22 ± 31 mm versus -43 ± 27 mm; mean difference 21 [95% CI 5 to 36]; p = 0.009 for the sagittal vertical axis). Such differences persisted at 2 years of follow-up. The proportion of patients with the desired correction was also greater in the four-poster frame group than in the Wilson frame group immediately postoperatively and at 2 years of follow-up (50% versus 21%, respectively; odds ratio 3.9 [95% CI 1.3 to 11.7]; p = 0.02; 43% versus 12%, respectively; odds ratio 5.6 [95% CI 1.6 to 20.3]; p = 0.005). We found no clinically important differences in postoperative patient-reported outcomes including Numeric Rating Scale and Oswestry Disability Index scores, and there were no differences in postoperative complications at 2 years of follow-up. CONCLUSION: The ideal patient position during surgery for an ASD should decrease intra-abdominal pressure and induce lordosis as the abdomen hangs freely and hip flexion is decreased. The four-poster frame appears advantageous for long-segment fusions for spinal deformities. Future studies are needed to extend our analyses to different types of spinal deformities and validate radiologic and clinical outcomes with follow-up for more than 2 years. LEVEL OF EVIDENCE LEVEL: III, therapeutic study.
引用
- Park HY, Kim YH, Ha KY, et al. Are the Choice of Frame and Intraoperative Patient Positioning Associated With Radiologic and Clinical Outcomes in Long-instrumented Lumbar Fusion for Adult Spinal Deformity? Clin Orthop Relat Res. 2021. PMID: 34904962. doi:10.1097/CORR.0000000000002084
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。