基于深度神经网络的点状上皮糜烂全自动分级系统
本研究开发了一套基于深度神经网络的点状上皮糜烂(PEE)全自动分级系统,通过角膜分割、图像分块和染色分级三步流程,对荧光素染色图像进行评分。结果显示,分割模型交并比为0.937,分级模型分类准确率76.5%,AUC为0.940(95%CI 0.932–0.949),全自动流程与临床评分相关系数0.908(p<0.01),Bland-Altman一致性限-4.125至3.720,单图处理平均耗时0.58秒。该系统可为临床试验和住院医师培训提供参考。
要点
- 全自动流程分割交并比0.937,分级AUC 0.940。
- 自动评分与临床评分相关系数0.908(p<0.01)。
- 单张染色图像处理平均耗时0.58秒。
核心结论
- 成功开发了评估点状上皮糜烂的全自动分级系统,其评分结果可作为临床试验和住院医师培训的参考。
研究设计与样本
- 开发全自动系统,对荧光素染色图像依次进行角膜分割、五个子区域图像块裁剪和染色评分(0–3分),全角膜自动评分0–15分。
- 将自动评分与三位眼科医生标注的临床评分进行比较。
主要发现
- 角膜分割模型交并比为0.937。
- 点状染色分级模型分类准确率为76.5%,AUC为0.940(95%CI 0.932–0.949)。
- 全自动流程与临床评分的Pearson相关系数为0.908(p<0.01)。
- Bland-Altman分析显示95%一致性限为-4.125至3.720,一致性相关系数为0.904。
- 单张染色图像处理平均耗时0.58秒。
临床怎么用
- 该系统可自动输出点状上皮糜烂分级评分,供眼科医生在临床试验和住院医师培训中参考。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: The goal was to develop a fully automated grading system for the evaluation of punctate epithelial erosions (PEEs) using deep neural networks. METHODS: A fully automated system was developed to detect corneal position and grade staining severity given a corneal fluorescein staining image. The fully automated pipeline consists of the following three steps: a corneal segmentation model extracts corneal area; five image patches are cropped from the staining image based on the five subregions of extracted cornea; a staining grading model predicts a score for each image patch from 0 to 3, and automated grading score for the whole cornea is obtained from 0 to 15. Finally, the clinical grading scores annotated by three ophthalmologists were compared with automated grading scores. RESULTS: For corneal segmentation, the segmentation model achieved an intersection over union of 0.937. For punctate staining grading, the grading model achieved a classification accuracy of 76.5% and an area under the receiver operating characteristic curve of 0.940 (95% CI 0.932 to 0.949). For the fully automated pipeline, Pearson's correlation coefficient between the clinical and automated grading scores was 0.908 (p<0.01). Bland-Altman analysis revealed 95% limits of agreement between the clinical and automated grading scores of between -4.125 and 3.720 (concordance correlation coefficient=0.904). The average time required for processing a single stained image during pipeline was 0.58 s. CONCLUSION: A fully automated grading system was developed to evaluate PEEs. The grading results may serve as a reference for ophthalmologists in clinical trials and residency training procedures.
引用
- Qu JH, Qin XR, Li CD, et al. Fully automated grading system for the evaluation of punctate epithelial erosions using deep neural networks. Br J Ophthalmol. 2021. PMID: 34670751. doi:10.1136/bjophthalmol-2021-319755
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。