软性接触镜佩戴对角膜高渗的保护作用
本文通过数学建模量化软性接触镜(SCL)后泪膜(PoLTF)的渗透压,发现其与临床测量的泪新月渗透压显著不同。水液缺乏型和蒸发过强型干眼均加剧PoLTF高渗,但低盐扩散系数的镜片可将干眼患者PoLTF渗透压降至无镜佩戴正常眼水平。眨眼频率降低会升高PoLTF渗透压,与镜片佩戴不适一致。
要点
- PoLTF渗透压与临床泪新月渗透压显著不同,临床测量未反映角膜实际暴露的渗透压。
- 低盐扩散系数的SCL可将干眼患者PoLTF渗透压降至无镜正常眼水平。
- 眨眼频率降低升高PoLTF渗透压,可能解释镜片佩戴不适。
核心结论
- 软性接触镜通过限制盐分跨镜传输,可降低PoLTF盐度,从而保护角膜免受高渗。
- PoLTF渗透压与临床泪新月渗透压显著不同,且与镜片佩戴不适可能存在关联。
研究设计与样本
- 本研究为数学建模研究,首次量化软性接触镜后泪膜(PoLTF)的渗透压。
主要发现
- PoLTF渗透压显著不同于临床测量的泪新月渗透压。
- 水液缺乏型干眼和蒸发过强型干眼均加剧PoLTF高渗。
- 低盐扩散系数的镜片可将干眼患者PoLTF渗透压降至无镜佩戴正常眼水平。
- 眨眼频率降低增加PoLTF渗透压,与镜片佩戴不适一致。
临床怎么用
- 临床测量泪新月渗透压不能代表角膜实际暴露的PoLTF渗透压。
- 设计低盐扩散系数的SCL材料可能改善角膜高渗和镜片佩戴不适。
局限性
- 本研究为数学建模,未提供临床验证数据。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Hyperosmotic tear stimulates human corneal nerve endings, activates ocular immune response, and elicits dry-eye symptoms. A soft contact lens (SCL) covers the cornea preventing it from experiencing direct tear evaporation and the resulting blink-periodic salinity increases. For the cornea to experience hyperosmolarity due to tear evaporation, salt must transport across the SCL to the post-lens tear film (PoLTF) bathing the cornea. Consequently, limited salt transport across a SCL potentially protects the ocular surface from hyperosmotic tear. In addition, despite lens-wear discomfort sharing common sensations to dry eye, no correlation is available between measured tear hyperosmolarity and SCL-wear discomfort. Lack of documentation is likely because clinical measurements of tear osmolarity during lens wear do not interrogate the tear osmolarity of the PoLTF that actually overlays the cornea. Rather, tear osmolarity is clinically measured in the tear meniscus. For the first time, we mathematically quantify tear osmolarity in the PoLTF and show that it differs significantly from the clinically measured tear-meniscus osmolarity. We show further that aqueous-deficient dry eye and evaporative dry eye both exacerbate the hyperosmolarity of the PoLTF. Nevertheless, depending on lens salt-transport properties (i.e., diffusivity, partition coefficient, and thickness), a SCL can indeed protect against corneal hyperosmolarity by reducing PoLTF salinity to below that of the ocular surface during no-lens wear. Importantly, PoLTF osmolarity for dry-eye patients can be reduced to that of normal eyes with no-lens wear provided that the lens exhibits a low lens-salt diffusivity. Infrequent blinking increases PoLTF osmolarity consistent with lens-wear discomfort. Judicious design of SCL material salt-transport properties can ameliorate corneal hyperosmolarity. Our results confirm the importance of PoLTF osmolarity during SCL wear and indicate a possible relation between PoLTF osmolarity and contact-lens discomfort.
引用
- Kim YH, Nguyen T, Lin MC, et al. Protection against corneal hyperosmolarity with soft-contact-lens wear. Prog Retin Eye Res. 2021. PMID: 34597771. doi:10.1016/j.preteyeres.2021.101012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。