文献速递白内障与屈光手术

有晶状体眼人工晶状体取出联合白内障手术的人工晶状体计算公式准确性

Accuracy of Intraocular Lens Calculation Formulas in Patients Undergoing Combined Phakic Intraocular Lens Removal and Cataract Surgery.
PubMed 文献 · Am J Ophthalmol · 2021-10-06

评估新型与传统人工晶状体(IOL)计算公式(含或不含Wang-Koch眼轴调整)的预测准确性,并分析IOLMaster 700测量前房深度(ACD)与晶状体厚度(LT)误差的影响。Kane公式及经WK眼轴调整的传统公式无显著系统预测误差、中位绝对误差较小;其他公式出现显著远视漂移。

要点

  • Kane公式及经WK眼轴调整的传统公式预测准确性相对较高。
  • 其他公式在该人群中显示显著远视漂移。
  • IOLMaster 700测后房型PIOL眼ACD与LT准确率低,但对IOL预测影响可忽略。

核心结论

  • 在有晶状体眼人工晶状体取出联合白内障手术患者中,Kane公式及经Wang-Koch眼轴调整的传统公式预测准确性相对较高。
  • 其他公式在该人群显示显著远视漂移且预测准确性相对较低。
  • IOLMaster 700在后房型PIOL眼测量ACD与LT准确率低,但对IOL预测准确性影响可忽略。

研究设计与样本

  • 回顾性、连续病例系列研究。
  • 评估新型公式(Barrett universal II、Emmetropia verifying optical、Kane、Ladas super formula)与传统公式(Haigis、Hoffer Q、Holladay 1、SRK/T)含或不含Wang-Koch(WK)眼轴调整的预测准确性。
  • 分析IOLMaster 700测量ACD与LT误差对屈光结果的影响。

主要发现

  • Kane公式及经WK眼轴调整的传统公式无显著系统预测误差,中位绝对误差较小。
  • 其他公式显示显著远视漂移(P < .05),预测准确性相对较低。
  • IOLMaster 700测量ACD与LT的准确率在前房型PIOL眼为100%,在PC-PIOL亚组为37.50%。
  • PC-PIOL亚组中使用正确与错误参数的公式屈光结果无显著差异(P > .05)。

关键数值与推荐

  • Kane公式及经WK眼轴调整的传统公式无显著系统预测误差且中位绝对误差较小。
  • 其他公式显示显著远视漂移(P < .05)。
  • IOLMaster 700测ACD与LT准确率:前房型PIOL眼100%,PC-PIOL亚组37.50%。
  • PC-PIOL亚组正确与错误参数公式屈光结果无显著差异(P > .05)。

临床怎么用

  • PIOL取出联合白内障手术的IOL度数计算可优先考虑Kane公式或经WK眼轴调整的传统公式。
  • 后房型PIOL眼用IOLMaster 700测ACD与LT准确性低,但对IOL预测准确性影响可忽略。

局限性

  • 仅评估IOLMaster 700的ACD与LT测量,未涉及其他生物测量设备。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To investigate the prediction accuracy of intraocular lens (IOL) calculation formulas, and the impact of anterior chamber depth (ACD) and lens thickness (LT) measurement errors on IOL power calculation in patients undergoing combined phakic IOL (PIOL) removal and cataract surgery. DESIGN: Retrospective, consecutive case series study. METHODS: Thirty-six PIOL implanted eyes (12 anterior chamber PIOLs and 24 posterior chamber PIOLs [PC-PIOL]) undergoing cataract surgery were included. The prediction accuracy of new formulas (Barrett universal II, Emmetropia verifying optical, Kane, and Ladas super formula) and traditional formulas (Haigis, Hoffer Q, Holladay 1 and SRK/T) with or without Wang-Koch (WK) axial length (AL) adjustment was evaluated. The influence of ACD and LT measurement errors of IOLMaster 700 on refractive outcomes was also investigated. RESULTS: The Kane and traditional formulas with WK AL adjustment had no significant systematic prediction error and displayed a smaller median absolute error, whereas the other formulas showed significant hyperopia shift (P < .05) and relatively lower prediction accuracy. The accuracy rate of IOLMaster 700 in measuring the ACD and LT was 100% in eyes with anterior chamber PIOL implantation, and 37.50% in the PC-PIOL subgroup. No significant difference was observed in refractive outcomes of formulas using correct and wrong parameters in the PC-PIOL subgroup (P > .05). CONCLUSIONS: The Kane and traditional formulas with WK AL adjustment exhibited relatively higher prediction accuracy in patients who underwent combined PIOL removal and cataract surgery. The IOLMaster 700 displayed low accuracy in ACD and LT measurements for PC-PIOL implanted eyes, but showed negligible impact on IOL prediction accuracy.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Zhang J, Xia Z, Han X, et al. Accuracy of Intraocular Lens Calculation Formulas in Patients Undergoing Combined Phakic Intraocular Lens Removal and Cataract Surgery. Am J Ophthalmol. 2021. PMID: 34624249. doi:10.1016/j.ajo.2021.09.035

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。