青光眼与非动脉炎性前部缺血性视神经病变的脉络膜微血管缺失地形对比分析
本研究对47只开角型青光眼(OAG)眼和19只伴有β区视盘周围萎缩(βPPA)的非动脉炎性前部缺血性视神经病变(NAION)眼进行OCT血管成像,比较脉络膜微血管缺失(MvD)的存在与地形分布。结果显示MvD在两组均存在,NAION眼出现率更高(19/19,100.0% vs 38/47,80.6%,P=0.050)且MvD与视网膜神经纤维层(RNFL)缺损更宽(均P<0.001)。MvD分布与βPPA和RNFL缺损叠加区域高度对应(均P<0.001),其轮廓与叠加区形态相似。
要点
- MvD在OAG和NAION眼中均可见,NAION眼出现率更高(100.0% vs 80.6%,P=0.050)。
- NAION眼的MvD和RNFL缺损宽度均大于OAG眼(均P<0.001)。
- MvD地形分布与βPPA和RNFL缺损叠加区高度匹配(均P<0.001)。
核心结论
- MvD在OAG和NAION眼中均存在,且NAION眼出现率更高。
- βPPA与RNFL缺损的叠加区域在地形和形态上与MvD匹配。
研究设计与样本
- 横断面比较研究,纳入47只OAG眼和19只伴有βPPA的NAION眼,均行OCT血管成像。
- 记录MvD存在与否,比较MvD、RNFL缺损和βPPA的角度宽度和位置。
主要发现
- MvD在NAION眼出现19/19(100.0%),在OAG眼出现38/47(80.6%),组间比较P=0.050。
- NAION眼的MvD和RNFL缺损宽度均大于OAG眼(均P<0.001)。
- MvD分布与βPPA和RNFL缺损叠加区域对应更强(均P<0.001),叠加区轮廓与MvD区域相似。
关键数值与推荐
- MvD存在率:NAION眼100.0%(19/19),OAG眼80.6%(38/47),P=0.050。
- NAION眼MvD和RNFL缺损宽度大于OAG眼,均P<0.001。
- MvD与βPPA和RNFL缺损叠加区对应性均P<0.001。
临床怎么用
- 在伴有βPPA的OAG和NAION眼中,OCT血管成像可评估MvD。
- MvD地形与βPPA和RNFL缺损叠加区一致,提示需结合RNFL缺损和βPPA位置解读MvD。
局限性
- 样本量较小(OAG 47眼,NAION 19眼),需进一步研究验证。
- MvD在NAION发病机制中的作用及临床意义尚不明确,需进一步研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To identify the presence of choroidal microvascular dropout (MvD) in nonarteritic anterior ischemic optic neuropathy (NAION) eyes and to characterize the topographical distribution for the mechanistic interpretation of MvD development. METHODS: We performed optical coherence tomography angiography on 47 open-angle glaucoma (OAG) and 19 NAION eyes with β-zone peripapillary atrophy (βPPA). We recorded the presence of MvD and compared between the peripapillary topographical measures of MvD, retinal nerve fiber layer (RNFL) defect, and βPPA in angular width and location. RESULTS: MvD was present in both diseases, marginally more frequently in NAION eyes (19/19, 100.0%) than in OAG eyes (38/47, 80.6%, P = 0.050), without a discernable difference in appearance. NAION eyes also showed wider MvD and RNFL defects compared to OAG eyes (both P < 0.001). In topographical measurements, the distribution of MvD showed a strong correspondence to superimposition areas of βPPA and RNFL defects, more distinctly than to RNFL defects (all P < 0.001). The outline of superimposition area also remarkably resembled the MvD area. CONCLUSIONS: MvD was present in both the OAG and NAION groups. The βPPA-RNFL defect superimposition area topographically and morphologically matched MvD. Further investigations are needed to elucidate the role of RNFL defects in the pathogenesis of MvD and the clinical significance.
引用
- Lee EJ, Kee HJ, Park KA, et al. Comparative Topographical Analysis of Choroidal Microvascular Dropout Between Glaucoma and Nonarteritic Anterior Ischemic Optic Neuropathy. Invest Ophthalmol Vis Sci. 2021. PMID: 34705024. doi:10.1167/iovs.62.13.27
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。