文献速递青光眼眼底病与葡萄膜炎

基于三维眼前段OCT的数字房角镜检查:国际多中心研究

Digital Gonioscopy Based on Three-dimensional Anterior-Segment OCT: An International Multicenter Study.
PubMed 文献 · Ophthalmology · 2021-10-05

本研究开发并评估基于三维深度学习自动数字房角镜系统(DGS)在疑似原发性闭角型青光眼(PACG)患眼OCT扫描中检测窄房角(静态房角镜,任务I)和周边前粘连(PAS)(动态房角镜,任务II)的性能。结果显示DGS在外部测试集上任务I的AUC为0.943,任务II象限水平AUC为0.902,钟点水平AUC为0.885,表明其有效且有望用于初级眼保健筛查。

要点

  • 3D DGS在外部测试集检测窄房角的AUC为0.943,敏感度0.867,特异度0.878。
  • 3D DGS检测PAS在象限水平AUC为0.902,敏感度0.900,特异度0.890。
  • 3D DGS检测PAS在钟点水平AUC为0.885,敏感度0.912,特异度0.700。

核心结论

  • 3D DGS能有效检测疑似PACG患眼,有望广泛用于初级眼保健社区筛查PACG高危人群。

研究设计与样本

  • 任务I训练/内部验证/外部测试体积扫描分别为4515、1101、2222个;任务II分别为378、376、102个。
  • 以房角镜记录为参考,评估3D DGS诊断性能,主要指标为AUC、敏感度和特异度。

主要发现

  • 任务I中29.4%患者有窄房角;外部测试集AUC 0.943(0.933-0.953),敏感度0.867(0.838-0.895),特异度0.878(0.859-0.896)。
  • 任务II中13.8%患者有PAS;外部测试集象限水平AUC 0.902(0.818-0.985),敏感度0.900(0.714-1.000),特异度0.890(0.841-0.938)。
  • 任务II外部测试集钟点水平AUC 0.885(0.836-0.933),敏感度0.912(0.816-1.000),特异度0.700(0.660-0.741)。

关键数值与推荐

  • 任务I窄房角定义:暗室原在位OCT扫描无压迫时,后部色素性小梁网在超过180°范围不可见。
  • 任务II PAS定义:虹膜与 trabecular meshwork 粘连。
  • 诊断性能评估以房角镜记录为参考标准。

临床怎么用

  • 3D DGS可作为初级眼保健中筛查PACG高危人群的自动化工具,辅助识别窄房角和PAS。
  • 临床解读时需注意任务II在钟点水平特异度较低(0.700),可能需结合其他检查确认。

局限性

  • 原文未报告研究局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To develop and evaluate the performance of a 3-dimensional (3D) deep-learning-based automated digital gonioscopy system (DGS) in detecting 2 major characteristics in eyes with suspected primary angle-closure glaucoma (PACG): (1) narrow iridocorneal angles (static gonioscopy, Task I) and (2) peripheral anterior synechiae (PAS) (dynamic gonioscopy, Task II) on OCT scans. DESIGN: International, cross-sectional, multicenter study. PARTICIPANTS: A total of 1.112 million images of 8694 volume scans (2294 patients) from 3 centers were included in this study (Task I, training/internal validation/external testing: 4515, 1101, and 2222 volume scans, respectively; Task II, training/internal validation/external testing: 378, 376, and 102 volume scans, respectively). METHODS: For Task I, a narrow angle was defined as an eye in which the posterior pigmented trabecular meshwork was not visible in more than 180° without indentation in the primary position captured in the dark room from the scans. For Task II, PAS was defined as the adhesion of the iris to the trabecular meshwork. The diagnostic performance of the 3D DGS was evaluated in both tasks with gonioscopic records as reference. MAIN OUTCOME MEASURES: The area under the curve (AUC), sensitivity, and specificity of the 3D DGS were calculated. RESULTS: In Task I, 29.4% of patients had a narrow angle. The AUC, sensitivity, and specificity of 3D DGS on the external testing datasets were 0.943 (0.933-0.953), 0.867 (0.838-0.895), and 0.878 (0.859-0.896), respectively. For Task II, 13.8% of patients had PAS. The AUC, sensitivity, and specificity of 3D DGS were 0.902 (0.818-0.985), 0.900 (0.714-1.000), and 0.890 (0.841-0.938), respectively, on the external testing set at quadrant level following normal clinical practice; and 0.885 (0.836-0.933), 0.912 (0.816-1.000), and 0.700 (0.660-0.741), respectively, on the external testing set at clock-hour level. CONCLUSIONS: The 3D DGS is effective in detecting eyes with suspected PACG. It has the potential to be used widely in the primary eye care community for screening of subjects at high risk of developing PACG.

来源:Ophthalmology,查看原文。版权归原作者所有。

引用

  1. Li F, Yang Y, Sun X, et al. Digital Gonioscopy Based on Three-dimensional Anterior-Segment OCT: An International Multicenter Study. Ophthalmology. 2021. PMID: 34619247. doi:10.1016/j.ophtha.2021.09.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。