原发性闭角型青光眼虹膜硬度与渗透性的变化
本研究纳入140例受试者(95例健康、45例原发性闭角型青光眼),通过前节OCT记录瞳孔缩小过程中的虹膜运动,结合有限元逆向模拟计算虹膜弹性模量和渗透性。结果显示原发性闭角型青光眼患者的虹膜硬度高于健康对照,而渗透性两组差异无统计学意义。
要点
- 原发性闭角型青光眼患者虹膜硬度高于健康对照(24.5 kPa vs 17.1 kPa,P<0.001)。
- 虹膜渗透性在两组间差异无统计学意义(P=0.142)。
- 基于前节OCT与有限元模拟可无创评估虹膜生物力学特性。
核心结论
- 原发性闭角型青光眼患者的虹膜生物力学特性与健康对照不同,表现为虹膜硬度更高。
研究设计与样本
- 研究共纳入140例受试者,其中健康95例、原发性闭角型青光眼45例,年龄分别为57.7±10.1岁和60.2±8.7岁。
- 在暗室中用1700 lux外部白光源诱导瞳孔缩小,同时行前节OCT扫描,分割虹膜并构建三维点云与有限元网格,通过逆向有限元模拟匹配临床观察到的虹膜收缩,以确定虹膜弹性模量和渗透性。
主要发现
- 所有140例受试者虹膜在瞳孔缩小过程中的模拟变形模式与OCT图像匹配良好。
- 在括约肌区域指定40 kPa主动应力时,原发性闭角型青光眼组虹膜硬度为24.5±8.4 kPa,健康对照组为17.1±6.6 kPa,组间差异有统计学意义(P<0.001)。
- 原发性闭角型青光眼组虹膜渗透性为0.41±0.2 mm2/kPa s,健康对照组为0.55±0.2 mm2/kPa s,组间差异无统计学意义(P=0.142)。
临床怎么用
- 虹膜硬度增高可能参与原发性闭角型青光眼的发病机制,深入理解虹膜生物力学行为可能有助于该病的认识和管理。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate the biomechanical properties of the iris by evaluating iris movement during pupil constriction and to compare such properties between healthy and primary angle-closure glaucoma (PACG) subjects. METHODS: A total of 140 subjects were recruited for this study. In a dark room, the anterior segments of one eye per subject were scanned using anterior segment optical coherence tomography imaging during induced pupil constriction with an external white light source of 1700 lux. Using a custom segmentation code, we automatically isolated the iris segments from the AS-OCT images, which were then discretized and transformed into a three-dimensional point cloud. For each iris, a finite element (FE) mesh was constructed from the point cloud, and an inverse FE simulation was performed to match the clinically observed iris constriction in the AS-OCT images. Through this optimization process, we were able to identify the elastic modulus and permeability of each iris. RESULTS: For all 140 subjects (95 healthy and 45 PACG of Indian/Chinese ethnicity; age 60.2 ± 8.7 for PACG subjects and 57.7 ± 10.1 for healthy subjects), the simulated deformation pattern of the iris during pupil constriction matched well with OCT images. We found that the iris stiffness was higher in PACG than in healthy controls (24.5 ± 8.4 kPa vs. 17.1 ± 6.6 kPa with 40 kPa of active stress specified in the sphincter region; P < 0.001), whereas iris permeability was lower (0.41 ± 0.2 mm2/kPa s vs. 0.55 ± 0.2 mm2/kPa s; p = 0.142). CONCLUSIONS: This study suggests that the biomechanical properties of the iris in PACG are different from those in healthy controls. An improved understanding of the biomechanical behavior of the iris may have implications for the understanding and management of angle-closure glaucoma.
引用
- Panda SK, Tan RKY, Tun TA, et al. Changes in Iris Stiffness and Permeability in Primary Angle Closure Glaucoma. Invest Ophthalmol Vis Sci. 2021. PMID: 34714323. doi:10.1167/iovs.62.13.29
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。