文献速递眼底病与葡萄膜炎

自适应光学OCT与微视野评估糖尿病黄斑缺血中光感受器结构与视网膜敏感度

Assessment of Detailed Photoreceptor Structure and Retinal Sensitivity in Diabetic Macular Ischemia Using Adaptive Optics-OCT and Microperimetry.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2021-01-01

该横断面观察性研究纳入4例糖尿病患者共5眼(2眼增殖性糖尿病视网膜病变,3眼中度非增殖性),用自适应光学OCT与微视野评估毛细血管无灌注区锥体光感受器密度、形态及对应视网膜敏感度。结果显示无灌注区锥体形态严重改变、信号密度降低约38%-39%,视网膜敏感度显著下降。

要点

  • 毛细血管无灌注区锥体光感受器形态严重改变,IS/OS和COST层面受累面积分别为84%和87%。
  • 无灌注区锥体信号密度较灌注完整区降低约38%-39%(P=0.01)。
  • 深部毛细血管丛无灌注区视网膜敏感度显著低于非受累区(10.8±5.4 vs 28.2±1.5,P<0.001)。

核心结论

  • 糖尿病眼毛细血管无灌注区锥体光感受器形态和信号密度严重改变,并伴随视网膜敏感度显著降低。

研究设计与样本

  • 横断面观察性研究,纳入4例患者共5眼,其中2眼为增殖性糖尿病视网膜病变、3眼为中度非增殖性糖尿病视网膜病变。
  • 采用自适应光学OCT在IS/OS和COST轴向位置手动评估锥体光感受器形态与密度,并用眼底控制微视野(MP-3,Nidek)测定对应区域视网膜敏感度。

主要发现

  • 毛细血管无灌注区IS/OS和COST层面锥体光感受器形态严重改变的面积占比分别为84%和87%,而灌注完整区分别为9%和8%。
  • 与相似偏心度、浅层和深层毛细血管丛灌注完整区相比,受累区锥体信号密度在IS/OS层面平均降低38%(P=0.01),在COST层面平均降低39%(P=0.01)。
  • 深部毛细血管丛无灌注受累区平均视网膜敏感度为10.8±5.4,非受累区为28.2±1.5(P<0.001)。

临床怎么用

  • 在糖尿病视网膜病变患者中,应关注毛细血管无灌注对锥体光感受器结构和视网膜敏感度的严重影响,重视预防毛细血管循环受损。

局限性

  • 样本量小(4例患者5眼),为横断面观察性研究,无法推断因果关系。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The purpose of this study was to assess density and morphology of cone photoreceptors (PRs) and corresponding retinal sensitivity in ischemic compared to nonischemic retinal capillary areas of diabetic eyes using adaptive optics optical coherence tomography (AO-OCT) and microperimetry (MP). METHODS: In this cross-sectional, observational study five eyes of four patients (2 eyes with proliferative diabetic retinopathy (DR) and 3 eyes moderate nonproliferative DR) were included. PR morphology and density was manually assessed in AO-OCT en face images both at the axial position of the inner-segment outer segment (IS/OS) and cone outer segment tips (COSTs). Retinal sensitivity was determined by fundus-controlled microperimetry in corresponding areas (MP-3, Nidek). RESULTS: In AO-OCT, areas affected by capillary nonperfusion showed severe alterations of cone PR morphology at IS/OS and COST compared to areas with intact capillary perfusion (84% and 87% vs. 9% and 8% of area affected for IS/OS and COST, respectively). Mean reduction of PR signal density in affected areas compared to those with intact superficial capillary plexus (SCP) and deep capillary plexus (DCP) perfusion of similar eccentricity was -38% at the level of IS/OS (P = 0.01) and -39% at the level of COST (P = 0.01). Mean retinal sensitivity was 10.8 ± 5.4 in areas affected by DCP nonperfusion and 28.2 ± 1.5 outside these areas (P < 0.001). CONCLUSIONS: Cone PR morphology and signal density are severely altered in areas of capillary nonperfusion. These structural changes are accompanied by a severe reduction of retinal sensitivity, indicating the importance of preventing impaired capillary circulation in patients with DR.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Datlinger F, Wassermann L, Reumueller A, et al. Assessment of Detailed Photoreceptor Structure and Retinal Sensitivity in Diabetic Macular Ischemia Using Adaptive Optics-OCT and Microperimetry. Invest Ophthalmol Vis Sci. 2021. PMID: 34605880. doi:10.1167/iovs.62.13.1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。