文献速递眼底病与葡萄膜炎

中心性浆液性脉络膜视网膜病变:自适应光学扫描激光检眼镜对无症状对侧眼的高分辨率成像

CENTRAL SEROUS CHORIORETINOPATHY: High-Resolution Imaging of Asymptomatic Fellow Eyes Using Adaptive Optics Scanning Laser Ophthalmoscopy.
PubMed 文献 · Retina · 2022-01-01

研究纳入17只单侧中心性浆液性脉络膜视网膜病变(CSCR)患者的无症状对侧眼及17只年龄性别匹配的健康对照眼,采用自适应光学检眼镜评估黄斑中心凹视锥细胞密度与间距。结果显示CSCR组对侧眼在黄斑中心凹鼻侧和颞侧2°偏心度处视锥细胞密度较对照组显著降低(P=0.001和P=0.027),而4°偏心度处无统计学显著差异。结论提示无症状对侧眼在视力正常且OCT光感受器线完整时已存在黄斑中心凹视锥细胞密度降低,光感受器损伤可能独立于浆液性视网膜脱离发生。

要点

  • 单侧CSCR患者无症状对侧眼黄斑中心凹鼻侧和颞侧2°偏心度处视锥细胞密度较健康对照显著降低。
  • 对侧眼在视力正常且OCT黄斑中心凹外界膜和椭圆体带完整的情况下已出现视锥细胞密度降低。
  • 4°偏心度处两组视锥细胞密度无统计学显著差异。

核心结论

  • 单侧CSCR患者无症状对侧眼在视力正常且OCT光感受器线完整时已存在黄斑中心凹视锥细胞密度降低,提示光感受器损伤可能独立于浆液性视网膜脱离发生。

研究设计与样本

  • 研究纳入17只单侧CSCR患者的无症状对侧眼和17只年龄、性别匹配的健康对照眼,均接受自适应光学检眼镜检查,评估黄斑中心凹视锥细胞密度和间距,并记录临床及多模式影像学表现。

主要发现

  • CSCR组患者平均年龄48.9±9.8岁,平均黄斑中心凹下脉络膜厚度417.8±125.2 µm,所有患者黄斑中心凹外界膜和椭圆体带完整。
  • 自适应光学眼底成像显示,与对照组相比,单侧CSCR患者无症状对侧眼在黄斑中心凹鼻侧和颞侧2°偏心度处视锥细胞密度显著降低(分别为P=0.001和P=0.027)。
  • 两组在黄斑中心凹鼻侧和颞侧4°偏心度处视锥细胞密度无统计学显著差异。

临床怎么用

  • 对于单侧CSCR患者,无症状对侧眼即使视力正常且OCT光感受器线完整,仍应关注黄斑中心凹视锥细胞密度的潜在降低。
  • 自适应光学检眼镜可检测CSCR患者对侧眼亚临床光感受器损伤,辅助评估病情。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To investigate cone density in the asymptomatic fellow eye of patients with unilateral central serous chorioretinopathy (CSCR). METHODS: Seventeen asymptomatic fellow eyes of patients with unilateral CSCR and 17 eyes of aged-matched and gender-matched healthy controls underwent adaptive optics ophthalmoscopy. Cone density and spacing were assessed at the fovea. Clinical and multimodal imaging findings were also recorded. RESULTS: In the CSCR group, the patient mean age was 48.9 ± 9.8 years. The mean (±SD) subfoveal choroidal thickness was 417.8 ± 125.2 µm. The foveal external limiting membrane and ellipsoid zone were intact in all patients. Adaptive optics fundus imaging showed a significant decrease in cone density at 2° of eccentricity nasal and temporal to the fovea in asymptomatic fellow eyes of patients with unilateral CSCR compared with controls (P = 0.001 and P = 0.027, respectively). No statistically significant difference in cone density was found at 4° of eccentricity nasal and temporal to the fovea between both groups. CONCLUSION: Asymptomatic fellow eyes of patients with unilateral CSCR showed a reduced density of foveal cones in the absence of a decreased visual acuity and photoreceptor line disruption on optical coherence tomography. These results suggest that the photoreceptors could be damaged independently of the occurrence of a serous retinal detachment.

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Gerardy M, Yesilirmak N, Legras R, et al. CENTRAL SEROUS CHORIORETINOPATHY: High-Resolution Imaging of Asymptomatic Fellow Eyes Using Adaptive Optics Scanning Laser Ophthalmoscopy. Retina. 2022. PMID: 34620798. doi:10.1097/IAE.0000000000003311

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。