文献速递青光眼角膜与眼表疾病

屈光不正与生物测量关系在原发性闭角型青光眼发病中的意义

Implications of the Relationship Between Refractive Error and Biometry in the Pathogenesis of Primary Angle Closure.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2021-01-01

该回顾性研究纳入119只原发性闭角型青光眼(PAC)眼和388只非PAC眼,所有眼轴长度(AL)≤25.0 mm且等效球镜(SE)≥-6.0 D。研究发现PAC眼角膜更平坦,且更平坦的角膜与远视屈光及更浅的前房深度(ACD)相关;在PAC眼中更浅的ACD与更近视的屈光相关,而非PAC眼无此关联。

要点

  • PAC眼角膜较非PAC眼更平坦(β=-0.448,P<0.001)。
  • PAC眼中更平坦角膜与更远视屈光(β=-0.454)和更浅ACD(β=0.073)相关,P<0.001。
  • PAC眼中更浅ACD与更近视屈光相关(β=1.117,P=0.006),非PAC眼无此关联。

核心结论

  • PAC眼似乎比非PAC眼具有更平坦的角膜。
  • 在PAC眼中,更浅的ACD似乎与更近视的屈光相关,而非PAC眼无此关联。

研究设计与样本

  • 回顾性研究纳入119只PAC眼和388只非PAC眼,眼轴长度≤25.0 mm且等效球镜≥-6.0 D。
  • 对角膜曲率值(K)、眼轴长度(AL)、前房深度(ACD)和等效球镜(SE)进行逐步多元回归分析。

主要发现

  • PAC眼更多为女性,眼压更高,眼轴长度更短。
  • 多元回归分析中,SE与PAC无关联。
  • PAC眼与非PAC眼之间,AL与SE或AL与ACD的关联无差异。
  • PAC眼角膜更平坦(β=-0.448,P<0.001)。
  • PAC眼中更平坦角膜与更远视屈光(β=-0.454,P<0.001)和更浅ACD(β=0.073,P<0.001)相关。

关键数值与推荐

  • PAC眼中更浅ACD与更近视屈光相关(β=1.117,P=0.006)。
  • 非PAC眼中ACD与SE无关联。

临床怎么用

  • 在PAC患者中评估角膜曲率和前房深度可能有助于理解屈光状态与房角关闭的关系。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The purpose of this study was to investigate the relationship between refractive error and ocular biometry and its implication in the pathogenesis of primary angle closure (PAC). METHODS: We have retrospectively recruited 119 PAC eyes and 388 non-PAC eyes with an axial length (AL) of ≤25.0 mm and a spherical equivalent (SE) of ≥-6.0 diopters (D). Stepwise multiple regression was performed for keratometry value (K), AL, anterior chamber depth (ACD), and SE. RESULTS: PAC eyes were more likely to be in women and have a higher IOP and shorter AL than non-PAC eyes. In a multiple regression analysis, SE was not associated with PAC. The associations between AL and SE or AL and ACD were not different in PAC eyes compared with non-PAC eyes. However, the cornea was flatter in PAC eyes (β = -0.448, P < 0.001), and a flatter cornea was associated with more hyperopic refraction (β = -0.454, P < 0.001) and shallower ACD (β = 0.073, P < 0.001) in PAC eyes. ACD was not associated with SE in non-PAC eyes, but shallower ACD was associated with greater myopic refraction in PAC eyes (β = 1.117, P = 0.006). CONCLUSIONS: PAC eyes seem to have flatter cornea compared with non-PAC eyes. A shallower ACD seems to be associated with greater myopic refraction in PAC eyes, but not in non-PAC eyes.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Shon K, Sung KR, Yoon JY, et al. Implications of the Relationship Between Refractive Error and Biometry in the Pathogenesis of Primary Angle Closure. Invest Ophthalmol Vis Sci. 2021. PMID: 34463718. doi:10.1167/iovs.62.10.38

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。