文献速递青光眼神经眼科

五种青光眼动物模型视觉通路异常的弥散张量成像研究

Diffusion Tensor Imaging of Visual Pathway Abnormalities in Five Glaucoma Animal Models.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2021-01-01

该研究用弥散张量成像(DTI)评估五种青光眼动物模型(两种诱导性、三种遗传性)的视觉通路完整性。结果显示,除转基因TBK1小鼠外,各模型眼压均显著升高;微珠和激光诱导的啮齿类模型、DBA/2J小鼠及LTBP2突变猫的视觉通路中分数各向异性显著降低、径向弥散率显著升高,DBA/2J小鼠还出现轴向弥散率降低,而转基因TBK1小鼠未见明显DTI改变。

要点

  • 慢性眼压升高伴随视神经或视束分数各向异性降低和径向弥散率升高。
  • DBA/2J小鼠额外显示轴向弥散率降低,其他模型未观察到。
  • 转基因TBK1小鼠眼压未显著升高且未见明显DTI改变。

核心结论

  • 在诱导性和遗传性青光眼动物模型中,慢性眼压升高伴随视神经或视束分数各向异性降低和径向弥散率升高,提示微结构完整性破坏。
  • 轴向弥散率的影响因模型而异,提示该DTI指标可能反映随时间与严重程度不同的病理改变。

研究设计与样本

  • 研究评估了两种实验诱导性和三种遗传决定性青光眼动物模型。
  • 诱导性模型通过前房内注射微珠或激光光凝小梁网建立慢性眼压升高。
  • 遗传性模型包括DBA/2J小鼠(色素性青光眼)、LTBP2突变猫(先天性青光眼)和转基因TBK1小鼠(正常眼压性青光眼),并与各自遗传匹配的健康对照比较。
  • 沿视神经和视束评估DTI参数,包括分数各向异性、轴向弥散率和径向弥散率。

主要发现

  • 除转基因TBK1小鼠外,各动物模型均观察到眼压较对照显著升高。
  • 微珠和激光诱导的啮齿类模型、DBA/2J小鼠及LTBP2突变猫的视觉通路中分数各向异性显著降低、径向弥散率显著升高。
  • DBA/2J小鼠还显示轴向弥散率降低,其他模型未观察到。
  • 转基因TBK1小鼠与对照相比未见明显DTI改变。

临床怎么用

  • DTI参数(分数各向异性降低、径向弥散率升高)可作为青光眼动物模型视觉通路微结构损伤的影像标志物。
  • 轴向弥散率的变化因模型而异,解读时需结合模型类型和疾病时间与严重程度。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To characterize the visual pathway integrity of five glaucoma animal models using diffusion tensor imaging (DTI). METHODS: Two experimentally induced and three genetically determined models of glaucoma were evaluated. For inducible models, chronic IOP elevation was achieved via intracameral injection of microbeads or laser photocoagulation of the trabecular meshwork in adult rodent eyes. For genetic models, the DBA/2J mouse model of pigmentary glaucoma, the LTBP2 mutant feline model of congenital glaucoma, and the transgenic TBK1 mouse model of normotensive glaucoma were compared with their respective genetically matched healthy controls. DTI parameters, including fractional anisotropy, axial diffusivity, and radial diffusivity, were evaluated along the optic nerve and optic tract. RESULTS: Significantly elevated IOP relative to controls was observed in each animal model except for the transgenic TBK1 mice. Significantly lower fractional anisotropy and higher radial diffusivity were observed along the visual pathways of the microbead- and laser-induced rodent models, the DBA/2J mice, and the LTBP2-mutant cats compared with their respective healthy controls. The DBA/2J mice also exhibited lower axial diffusivity, which was not observed in the other models examined. No apparent DTI change was observed in the transgenic TBK1 mice compared with controls. CONCLUSIONS: Chronic IOP elevation was accompanied by decreased fractional anisotropy and increased radial diffusivity along the optic nerve or optic tract, suggestive of disrupted microstructural integrity in both inducible and genetic glaucoma animal models. The effects on axial diffusivity differed between models, indicating that this DTI metric may represent different aspects of pathological changes over time and with severity.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Colbert MK, Ho LC, van der Merwe Y, et al. Diffusion Tensor Imaging of Visual Pathway Abnormalities in Five Glaucoma Animal Models. Invest Ophthalmol Vis Sci. 2021. PMID: 34410298. doi:10.1167/iovs.62.10.21

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。