青光眼中黄斑中心OCTA参数的研究
结果显示中心凹血管密度FD300与中心10°视野平均偏差和黄斑阈值相关,而FAZ面积与这些视野参数无关,但较小的FAZ面积与较低眼压相关。
要点
- FD300降低与24-2和10-2视野平均偏差及黄斑阈值变差相关。
- FAZ面积在健康、疑似青光眼和POAG三组间无显著差异。
- 较小的FAZ面积与较低眼压相关。
核心结论
- 在健康、疑似青光眼和POAG眼中,FD300而非FAZ面积与10°中心视野平均偏差和黄斑阈值相关。
- 较小的FAZ面积与较低眼压相关。
研究设计与样本
- 所有受试者接受OCTA成像和标准自动视野计检查(24-2和10-2 SITA)。
- 测量OCTA和OCT的FAZ参数(浅层FAZ面积、FAZ周长)、中心凹血管密度FD300和中心凹厚度。
- 使用线性混合模型评估FAZ参数与视野参数的相关性。
主要发现
- 轴长调整后的FAZ面积在三组间无差异:健康组0.31(95%CI 0.27-0.36)mm²,疑似青光眼组0.29(0.26-0.31)mm²,POAG组0.28(0.27-0.30)mm²(p=0.578)。
- FD300在疑似青光眼组为49.1%(47.9%-50.4%),POAG组为48.7%(48.1%-49.4%),健康组为50.5%(49.3%-51.7%),差异无统计学意义(p=0.071)。
- 在多变量线性混合模型中,较低的FD300与较差的24-2和10-2视野平均偏差及黄斑阈值相关(所有p<0.05)。
- 较小的FAZ面积与较低眼压相关(p=0.026)。
临床怎么用
- OCTA测量的FD300可能有助于评估青光眼中心视野功能损害。
- FAZ面积不宜作为青光眼中心视野损害的指标。
- FAZ面积与眼压的关联需进一步研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND/AIMS: To investigate the relationship between the foveal avascular zone (FAZ) parameters assessed by optical coherence tomography angiography (OCTA) and central visual field parameters in glaucoma and healthy subjects. METHODS: One hundred and eighty-eight subjects (248 eyes), including 24 healthy (38 eyes), 37 glaucoma suspect (42 eyes, and 127 primary open angle glaucoma (POAG) patients (168 eyes), underwent imaging using OCTA and standard automated perimetry using the 24-2 and 10-2 Swedish Interactive Thresholding Algorithm. OCTA-based and OCT-based FAZ parameters (superficial FAZ area, FAZ circumference), foveal vessel density (FD300) and foveal thickness were measured. The correlation between FAZ parameters and visual field parameters was assessed using linear mixed model. RESULTS: Axial length adjusted-FAZ area was not different among the three groups (mean (95% CI)): in healthy 0.31 (0.27 to 0.36) mm2, glaucoma suspect 0.29 (0.26 to 0.31) mm2 and POAG eyes 0.28 (0.27 to 0.30) mm2 (p=0.578). FD300 was lower in glaucoma suspect 49.1% (47.9% to 50.4%) and POAG eyes 48.7% (48.1% to 49.4%) than healthy eyes 50.5% (49.3% to 51.7%) though the difference was not statistically significant (p=0.071). Lower FD300 was associated with worse 24-2 and 10-2 visual field mean deviation and foveal threshold in multivariable linear mixed models (all p<0.05). In addition, a smaller FAZ area was associated with lower intraocular pressure (IOP) (p=0.026). CONCLUSIONS: The FD300, but not the FAZ area was correlated with 10° central visual field mean deviation and foveal threshold in healthy, glaucoma suspect and POAG eyes. In contrast, a smaller FAZ area was associated with lower IOP.
引用
- Nishida T, Oh WH, Moghimi S, et al. Central macular OCTA parameters in glaucoma. Br J Ophthalmol. 2021. PMID: 34426401. doi:10.1136/bjophthalmol-2021-319574
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。