文献速递青光眼

扫频源前节OCT对原发性房角关闭疾病的诊断性能评估

Evaluation of the Diagnostic Performance of Swept-Source Anterior Segment Optical Coherence Tomography in Primary Angle Closure Disease.
PubMed 文献 · Am J Ophthalmol · 2021-07-17

这项多中心横断面研究评估了扫频源前节OCT在区分原发性房角关闭疾病(PACD)与正常眼、以及区分原发性房角关闭(PAC)/PAC青光眼(PACG)与PAC可疑(PACS)中的诊断性能。研究利用训练集和独立验证集构建逻辑回归模型,发现平均前房深度区分PACD与对照眼的AUC最高(0.94),而多变量模型区分PAC/PACG与PACS的AUC为0.83。结论认为SS-OCT对PACD与正常眼的鉴别诊断性能优异,对PAC/PACG与PACS的鉴别能力中等。

要点

  • 平均前房深度区分PACD与对照眼的AUC为0.94,切点2.2 mm时敏感度90.2%、特异度85.2%。
  • 多变量模型区分PAC/PACG与PACS的AUC为0.83,训练集敏感度82.0%、特异度62.8%。
  • 验证集证实了上述诊断模型的性能,前房深度单独即可作为简单有效的PACD筛查指标。

核心结论

  • SS-OCT前节成像区分PACD与正常眼诊断性能优异,区分PAC/PACG与PACS诊断能力中等。
  • 平均前房深度单独即可简单有效地区分PACD与对照眼,且可通过其他更普及的设备获取。

研究设计与样本

  • 多中心横断面研究,中国患者分为对照、PACS和PAC/PACG三组。
  • 训练集纳入260例患者的366只眼共2928张SS-OCT图像,验证集纳入143例患者的147只眼共1176张SS-OCT图像。
  • 采用逻辑回归模型的受试者工作特征曲线下面积(AUC)评估判别能力,并计算敏感度与特异度,用独立数据集验证模型性能。

主要发现

  • 区分PACD与对照眼时,平均前房深度的AUC最高,为0.94。
  • 平均前房深度以2.2 mm为切点时,训练集敏感度为90.2%、特异度为85.2%。
  • 区分PAC/PACG与PACS时,多变量模型的AUC为0.83,训练集敏感度为82.0%、特异度为62.8%。
  • 验证集证实了上述发现。

关键数值与推荐

  • 平均前房深度区分PACD与对照眼的AUC为0.94,切点2.2 mm时敏感度90.2%、特异度85.2%。
  • 多变量模型区分PAC/PACG与PACS的AUC为0.83,训练集敏感度82.0%、特异度62.8%。

临床怎么用

  • SS-OCT测量的平均前房深度可作为区分PACD与正常眼的简单有效指标,有助于PACD的早期诊断。
  • 前房深度可通过其他更普及的检查设备获取,便于在临床中推广用于PACD筛查。
  • 区分PAC/PACG与PACS时需采用多变量模型,其诊断能力中等,解读结果时应结合临床。

局限性

  • 研究仅纳入中国患者,结论外推至其他人群需谨慎。
  • 区分PAC/PACG与PACS的多变量模型特异度较低(62.8%),存在一定假阳性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate the diagnostic performance of swept-source anterior segment optical coherence tomography (SS-OCT) in differentiating eyes with primary angle closure disease (PACD) from eyes of control subjects, as well as eyes with PAC and PAC glaucoma (PACG) from eyes with PAC suspect (PACS) disease. DESIGN: Multicenter cross-sectional study. METHODS: Chinese patients were classified into control, PACS, and PAC/PACG groups. The area under the receiving operating characteristic curve (AUC) from logistic regression models was used to evaluate discriminating ability. Sensitivity and specificity were calculated, and performance of the models was validated using an independent dataset. RESULTS: A total of 2928 SS-OCT images from 366 eyes of 260 patients were recruited to develop diagnostic models. The validation dataset included 1176 SS-OCT images from 147 eyes of 143 patients. For distinguishing PACD from control eyes, average anterior chamber depth had the highest AUC (0.94). With a cutoff of 2.2 mm for average anterior chamber depth, the sensitivity and specificity were 90.2% and 85.2% in the training set. For distinguishing PAC/PACG from PACS, a multivariate model had an AUC of 0.83, with sensitivity and specificity of 82.0% and 62.8% in the training set. The validation set confirmed the findings. CONCLUSIONS: SS-OCT of the anterior segment showed excellent diagnostic performance distinguishing PACD from normal eyes and moderate diagnostic ability distinguishing eyes with PAC/PACG from eyes with PACS. ACD alone may provide a simple and effective way to diagnose PACD from control subjects. As ACD can be obtained using other more available modalities, this has implications for the early diagnosis of PACD.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Ma P, Wu Y, Oatts J, et al. Evaluation of the Diagnostic Performance of Swept-Source Anterior Segment Optical Coherence Tomography in Primary Angle Closure Disease. Am J Ophthalmol. 2021. PMID: 34283974. doi:10.1016/j.ajo.2021.06.033

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。