青光眼患者L/M视锥分离ON/OFF视网膜电图的后受体通路反应
PURPOSE: To compare the electroretinographical (ERG) responses elicited by L- and M-cone isolating ON- and OFF-sawtooth stimuli in normal subjects and glaucoma patients. METHODS: Twenty-one normal subjects and 44 primary open-angle glaucoma patients participated in the study.…
要点
- 70°视锥分离锯齿波ERG反映视锥拮抗反应。
- 青光眼患者L-加反应晚期负成分显著减小。
- 中心亮度信号在青光眼中主要受影响。
核心结论
- 70°视锥分离锯齿波ERG的视锥拮抗反应在青光眼与正常人无显著差异。
- 亮度驱动的L-加反应显著不同,提示中心亮度信号主要受青光眼影响。
研究设计与样本
- 采用三重沉默替代技术生成L和M视锥分离的快速ON和OFF锯齿波刺激(18%视锥对比度;284 cd/m2;4 Hz),刺激大小包括全视野和中心70°直径。
主要发现
- L-ON与M-OFF刺激反应以及M-ON与L-OFF刺激反应彼此相似,尤其在70°刺激下。
- PL-add振幅在正常人与青光眼患者间无显著差异,而LNL-add振幅在青光眼患者中显著减小(P < 0.01)。
- PM-add和LNM-add在两组间无显著差异。
- 0.8°检查大小的PERG振幅及0.8°/16°振幅比(PERG ratio)在两组间显著不同(P < 0.05)。
- 70° LNL-add振幅和0.8° PERG振幅与视网膜神经纤维层厚度显著相关。
关键数值与推荐
- L-加反应晚期负成分(LNL-add)振幅在青光眼患者中显著小于正常人(P < 0.01)。
- 0.8° PERG振幅及PERG ratio在两组间显著不同(P < 0.05)。
临床怎么用
- 70°视锥分离锯齿波ERG的L-加反应晚期负成分可能有助于评估青光眼中心亮度通路损伤。
- 该指标与视网膜神经纤维层厚度相关,可辅助监测青光眼结构改变。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To compare the electroretinographical (ERG) responses elicited by L- and M-cone isolating ON- and OFF-sawtooth stimuli in normal subjects and glaucoma patients. METHODS: Twenty-one normal subjects and 44 primary open-angle glaucoma patients participated in the study. L- and M-cone isolating (18% cone contrast; 284 cd/m2) rapid ON- and rapid OFF-sawtooth (4 Hz) stimuli with two stimulus sizes (full-field (FF) and central 70° diameter) were generated using the triple silent substitution technique. ON- and OFF-response asymmetries were studied by adding the two (to obtain L-add and M-add responses). The initial positive (P) and subsequent late negative (LN) components of the L-add and M-add ERGs were compared between the subject groups and correlated with retinal nerve fiber layer thickness (RNFLT) and pattern ERG responses. RESULTS: The responses to L-ON and to M-OFF stimuli and vice versa resembled each other particularly with 70° stimuli. The PL-add amplitudes were not significantly different between the normal subjects and glaucoma patients, whereas the LNL-add amplitude was significantly (P < 0.01) smaller in the glaucoma patients. Both PM-add and LNM-add were not significantly different between the subject groups. The PERG amplitude with 0.8° check sizes and the 0.8°/16° amplitude ratio (PERG ratio) were significantly (P < 0.05) different between the subject groups. The 70° LNL-add amplitude and the 0.8° PERG amplitude were significantly correlated with RNFLT. CONCLUSIONS: The ERGs to 70° cone isolating sawtooth stimuli reflect cone opponency. The cone opponent ERG responses were not significantly different between glaucoma patients and normal subjects. Luminance driven L-add responses were significantly different, indicating that central luminance signals are mainly affected in glaucoma.