文献速递青光眼眼底病与葡萄膜炎

青光眼患者L/M视锥分离ON/OFF视网膜电图的后受体通路反应

Responses of Postreceptoral Pathways Elicited by L- and M-Cone Isolating ON- and OFF-Electroretinograms in Glaucoma Patients.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2021-01-01

PURPOSE: To compare the electroretinographical (ERG) responses elicited by L- and M-cone isolating ON- and OFF-sawtooth stimuli in normal subjects and glaucoma patients. METHODS: Twenty-one normal subjects and 44 primary open-angle glaucoma patients participated in the study.…

要点

  • 70°视锥分离锯齿波ERG反映视锥拮抗反应。
  • 青光眼患者L-加反应晚期负成分显著减小。
  • 中心亮度信号在青光眼中主要受影响。

核心结论

  • 70°视锥分离锯齿波ERG的视锥拮抗反应在青光眼与正常人无显著差异。
  • 亮度驱动的L-加反应显著不同,提示中心亮度信号主要受青光眼影响。

研究设计与样本

  • 采用三重沉默替代技术生成L和M视锥分离的快速ON和OFF锯齿波刺激(18%视锥对比度;284 cd/m2;4 Hz),刺激大小包括全视野和中心70°直径。

主要发现

  • L-ON与M-OFF刺激反应以及M-ON与L-OFF刺激反应彼此相似,尤其在70°刺激下。
  • PL-add振幅在正常人与青光眼患者间无显著差异,而LNL-add振幅在青光眼患者中显著减小(P < 0.01)。
  • PM-add和LNM-add在两组间无显著差异。
  • 0.8°检查大小的PERG振幅及0.8°/16°振幅比(PERG ratio)在两组间显著不同(P < 0.05)。
  • 70° LNL-add振幅和0.8° PERG振幅与视网膜神经纤维层厚度显著相关。

关键数值与推荐

  • L-加反应晚期负成分(LNL-add)振幅在青光眼患者中显著小于正常人(P < 0.01)。
  • 0.8° PERG振幅及PERG ratio在两组间显著不同(P < 0.05)。

临床怎么用

  • 70°视锥分离锯齿波ERG的L-加反应晚期负成分可能有助于评估青光眼中心亮度通路损伤。
  • 该指标与视网膜神经纤维层厚度相关,可辅助监测青光眼结构改变。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To compare the electroretinographical (ERG) responses elicited by L- and M-cone isolating ON- and OFF-sawtooth stimuli in normal subjects and glaucoma patients. METHODS: Twenty-one normal subjects and 44 primary open-angle glaucoma patients participated in the study. L- and M-cone isolating (18% cone contrast; 284 cd/m2) rapid ON- and rapid OFF-sawtooth (4 Hz) stimuli with two stimulus sizes (full-field (FF) and central 70° diameter) were generated using the triple silent substitution technique. ON- and OFF-response asymmetries were studied by adding the two (to obtain L-add and M-add responses). The initial positive (P) and subsequent late negative (LN) components of the L-add and M-add ERGs were compared between the subject groups and correlated with retinal nerve fiber layer thickness (RNFLT) and pattern ERG responses. RESULTS: The responses to L-ON and to M-OFF stimuli and vice versa resembled each other particularly with 70° stimuli. The PL-add amplitudes were not significantly different between the normal subjects and glaucoma patients, whereas the LNL-add amplitude was significantly (P < 0.01) smaller in the glaucoma patients. Both PM-add and LNM-add were not significantly different between the subject groups. The PERG amplitude with 0.8° check sizes and the 0.8°/16° amplitude ratio (PERG ratio) were significantly (P < 0.05) different between the subject groups. The 70° LNL-add amplitude and the 0.8° PERG amplitude were significantly correlated with RNFLT. CONCLUSIONS: The ERGs to 70° cone isolating sawtooth stimuli reflect cone opponency. The cone opponent ERG responses were not significantly different between glaucoma patients and normal subjects. Luminance driven L-add responses were significantly different, indicating that central luminance signals are mainly affected in glaucoma.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Aher AJ, Horn FK, Huchzermeyer C, et al. Responses of Postreceptoral Pathways Elicited by L- and M-Cone Isolating ON- and OFF-Electroretinograms in Glaucoma Patients. Invest Ophthalmol Vis Sci. 2021. PMID: 34241626. doi:10.1167/iovs.62.9.14

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。