文献速递青光眼角膜与眼表疾病

眼前节OCT评估剥脱综合征眼前节参数

Evaluation of Anterior Segment Parameters in Pseudoexfoliation Disease Using Anterior Segment Optical Coherence Tomography.
PubMed 文献 · Am J Ophthalmol · 2021-07-28

这项横断面研究用眼前节OCT比较剥脱综合征(PEX)、剥脱性青光眼(PEXG)与正常对照的眼前节及房角参数。结果显示PEXG眼前房更浅、房角参数更低,且从对照到PEX再到PEXG呈进行性下降。

要点

  • PEXG眼的前房深度显著浅于正常对照眼(P < .001)。
  • AOD500、AOD750、TISA500、TISA750在三组间差异显著,PEXG组最低。
  • 晶状体拱高在PEXG组和PEX组高于对照组。

核心结论

  • PEXG眼具有最窄的眼前房角参数。
  • 从正常对照到PEX再到PEXG,房角参数呈进行性下降。
  • 窄前房角与前房深度可能在PEX向PEXG进展中起作用。

研究设计与样本

  • 横断面研究,受试者来自学术转诊机构。
  • 所有受试者接受完整眼科检查、眼轴测量和眼前节OCT成像。
  • 排除4只因巩膜突成像不佳的眼后,分析PEXG 34眼、PEX 33眼、对照31眼。

主要发现

  • PEXG眼前房深度显著浅于对照眼(P < .001)。
  • AOD500、AOD750、TISA500、TISA750在三组间差异显著,PEXG组低于PEX组和对照组。
  • 晶状体拱高(均值±SD,mm)在PEXG组为0.46 ±0.21,PEX组为0.427 +0.28,对照组为0.305+ 0.20。

临床怎么用

  • 检测PEX患者的窄房角可能有助于临床医生更恰当地管理疾病。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To compare anterior segment and angle parameters between pseudoexfoliation syndrome (PEX) and PEX glaucoma (PEXG) and normal control subjects using anterior segment optical coherence tomography (AS-OCT) imaging. DESIGN: Cross-sectional study. METHODS: One hundred and two subjects with PEXG, PEX, and normal eyes as the control group were recruited from an academic referral institution. All subjects underwent a complete ophthalmologic examination, axial length measurement, and AS-OCT imaging. Anterior segment and angle parameters were evaluated. RESULTS: After excluding 4 eyes because of poor imaging of the scleral spur, data from 34 eyes with PEXG, 33 eyes with PEX, and 31 eyes of normal control subjects were analyzed. Anterior chamber depth was significantly shallower in eyes with PEXG compared with eyes of control subjects (P < .001). The differences in anterior chamber angle parameters (AOD500, AOD750, TISA500,and TISA750) were significant among study groups, with lower values in the PEXG group compared with the PEX and control subject groups. Lens vault (mean [mm]±SD) was higher in the PEXG (0.46 ±0.21) and PEX (0.427 +0.28) groups compared with the control group (0.305+ 0.20). CONCLUSIONS: PEXG eyes have the narrowest anterior chamber angle parameters. There is a progressive decrease in angle parameters from control subjects to the PEX group to the PEXG group. Narrow anterior chamber angle and anterior chamber depth may have a role in the progression of PEX to PEXG. Detection of narrow angle in these patients may help clinicians manage the disease more properly.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Mohammadi M, Johari M, Eslami Y, et al. Evaluation of Anterior Segment Parameters in Pseudoexfoliation Disease Using Anterior Segment Optical Coherence Tomography. Am J Ophthalmol. 2021. PMID: 34329617. doi:10.1016/j.ajo.2021.07.025

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。