青光眼筛查中结构与功能联合分析的应用评估
基于芬兰北部出生队列眼研究3001名45-49岁白种人随机样本,评估联合SD-OCT与标准自动视野计的S-F分析在青光眼筛查中的适用性。在97.5%特异性下,S-F分析敏感度44%,高于OCT的26%和SAP的35%,SAP表现略优于OCT,但S-F分析可提升诊断能力。
要点
- 在97.5%特异性下,S-F分析敏感度44%,高于SAP的35%和OCT的26%。
- SAP在中年人群青光眼筛查中表现略优于OCT。
- 结合OCT、SAP和缺损定位数据的分类树方法在90%特异性下敏感度达77%。
核心结论
- SAP在中年人群青光眼筛查中表现略优于OCT,但S-F分析可提升诊断能力。
研究设计与样本
- 芬兰北部出生队列眼研究的3001名45-49岁白种人随机样本,接受眼科检查包括24-2 SAP、视盘和RNFL照相及SD-OCT。
- S-F报告由Forum Glaucoma Workplace软件生成,OCT、SAP和S-F分析均对照临床青光眼诊断(基于视盘和RNFL照相及视野的「3项中2项阳性」规则)进行评估。
主要发现
- 在97.5%特异性下,青光眼性损伤的敏感度:异常OCT为26%,SAP为35%,S-F分析为44%。
- 估计曲线下面积分别为0.74、0.85和0.76,相应阳性预测值分别为8%、10%和12%。
- 采用结合OCT、SAP和缺损定位数据的分类树方法,在90%特异性下敏感度达77%。
- 在结构与功能缺损定位分析中,若异常视野测试点位于OCT边界或异常区域,与青光眼的相关性显著增加。
关键数值与推荐
- 临床青光眼诊断采用阳性「3项中2项」规则,基于临床医生对ONH和RNFL照相及视野的评估。
临床怎么用
- 在中年人群青光眼筛查中,SAP筛查性能略优于OCT,但联合S-F分析可改善诊断能力。
- 结合OCT、SAP和缺损定位数据的分类树方法可在90%特异性下达到77%敏感度。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To assess the applicability of a structure-function (S-F) analysis combining spectral-domain optical coherence tomography (SD-OCT) and standard automated perimetry (SAP) in glaucoma screening in a middle-aged population. METHODS: A randomised sample of 3001 Caucasian participants aged 45-49 years of the Northern Finland Birth Cohort Eye Study was examined. We performed an eye examination, including 24-2 SAP, optic nerve head (ONH) and retinal nerve fibre layer (RNFL) photography and SD-OCT of the peripapillary RNFL. The S-F report was generated by Forum Glaucoma Workplace software. OCT, SAP and the S-F analysis were evaluated against clinical glaucoma diagnosis, that is, the positive '2 out of 3' rule based on the clinician's evaluation of ONH and RNFL photographs and visual fields (VFs). RESULTS: At a specificity of 97.5%, the sensitivity for glaucomatous damage was 26% for abnormal OCT, 35% for SAP and 44% for S-F analysis. Estimated areas under the curve were 0.74, 0.85 and 0.76, and the corresponding positive predictive values were 8 %, 10% and 12%, respectively. By applying a classification tree approach combining OCT, SAP and defect localisation data, a sensitivity of 77% was achieved at 90% specificity. In a localisation analysis of glaucomatous structural and functional defects, the correlation with glaucoma increased significantly if the abnormal VF test points were located on borderline or abnormal OCT zones. CONCLUSION: SAP performs slightly better than OCT in glaucoma screening of middle-aged population. However, the diagnostic capability can be improved by S-F analysis.
引用
- Karvonen E, Stoor K, Luodonpää M, et al. Combined structure-function analysis in glaucoma screening. Br J Ophthalmol. 2021. PMID: 34230023. doi:10.1136/bjophthalmol-2021-319178
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。