青光眼及可疑青光眼患者的标准可靠性指标与注视追踪指标
这项回顾性横断面研究纳入494例青光眼及可疑青光眼患者,双眼行Humphrey视野计24-2 SITA Fast检查,比较标准可靠性指标(固视丢失、假阳性、假阴性)与注视追踪指标(1°-2°、3°-5°、>6°偏差及追踪失败频率)。结果显示两者虽在95百分位截断下存在统计学显著相关,但Spearman相关系数低且AUROC计算提示关联临床意义有限;假阴性和>6°偏差受视野缺损严重程度影响。
要点
- 注视追踪指标与标准可靠性指标相关性弱,临床意义有限。
- 假阴性随视野缺损严重程度加重而增加(P < .001)。
- >6°偏差在轻度视野缺损眼中低于中度和重度缺损眼(P = .012)。
核心结论
- 注视追踪指标与标准可靠性指标无临床显著关联。
- 假阴性和>6°偏差均受视野缺损严重程度影响。
- 聚合注视追踪指标无助于可靠性评估,但可能提供替代或补充的视野可靠性测量。
研究设计与样本
- 回顾性横断面研究,在VA医疗中心(圣迭戈)进行。
- 纳入494例青光眼及可疑青光眼患者,双眼行HFA 24-2 SITA Fast视野检查。
- 比较标准可靠性指标(固视丢失、假阳性、假阴性)与注视追踪指标(1°-2°偏差[M1]、3°-5°偏差[M3]、>6°偏差[M6]、追踪失败频率[TFF])。
- 主要结局指标为Spearman秩相关系数和受试者工作特征曲线下面积(AUROC)。
主要发现
- 注视追踪指标的95百分位上限:M1为66.7%,M3为67.5%,M6为49.5%,TFF为79.8%。
- 以95百分位作为二分类截断时,标准与注视追踪可靠性指标间存在统计学显著相关。
- Spearman相关系数低且AUROC计算提示这些关联临床意义有限。
- 假阴性随视野严重程度恶化而增加(P < .001)。
- M6在轻度视野缺损眼中低于中度和重度视野缺损眼(P = .012)。
关键数值与推荐
- 注视追踪指标95百分位上限:M1 66.7%,M3 67.5%,M6 49.5%,TFF 79.8%。
- 假阴性随视野严重程度增加(P < .001);M6在轻度 vs 中度和重度视野缺损中较低(P = .012)。
临床怎么用
- 临床不应依赖聚合注视追踪指标来评估视野检查可靠性。
- 解读视野可靠性时需考虑视野缺损严重程度对假阴性和>6°偏差的影响。
- 注视追踪指标可能作为视野可靠性的替代或补充测量,但需进一步研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To compare standard reliability metrics and gaze tracking (GT) metrics on the Humphrey field analyzer (HFA). DESIGN: Retrospective cross-sectional study. METHODS: The study was performed at the VA Medical Center, San Diego, and included 494 glaucoma and glaucoma suspect patients who had an HFA 24-2 SITA Fast visual field (VF) performed in both eyes. Standard reliability metrics (fixation loss [FL], false-positive [FP], and false-negative [FN]) were compared to GT metrics (deviations of 1°-2° [M1], deviations of 3°-5° [M3], deviations >6° [M6], and tracking failure frequency [TFF]). The main outcome measures were Spearman rank-based correlation coefficient and area under the receiver operating characteristic (AUROC) curves between standard and GT reliability metrics. RESULTS: The 95th percentile limits for GT metrics were 66.7% for M1, 67.5% for M3, 49.5% for M6, and 79.8% for TFF. There were statistically significant correlations between standard and GT reliability metrics using the 95th percentile as a binary cutoff for GT metrics. However, low Spearman correlation values and AUROC calculations suggest little clinical significance of the associations. FN increased as VF severity worsened (P < .001). M6 was lower in eyes with mild compared to moderate and advanced VF loss (P = .012). CONCLUSIONS: GT metrics do not have a clinically significant association with standard reliability metrics. Both FN and M6 are influenced by VF severity. Aggregate GT metrics do not aid in reliability assessment. These findings suggest that GT metrics may provide an alternative or complementary measure of VF reliability.
引用
- Camp AS, Long CP, Patella VM, et al. Standard Reliability and Gaze Tracking Metrics in Glaucoma and Glaucoma Suspects. Am J Ophthalmol. 2021. PMID: 34280366. doi:10.1016/j.ajo.2021.06.038
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。