RETeval 闪烁视网膜电图评估密集玻璃体出血
这项回顾性病例系列研究纳入69眼急性密集玻璃体出血,用RETeval闪烁视网膜电图评估。视网膜脱离眼振幅比极低,诊断视网膜脱离的曲线下面积0.977,最佳截断值0.14,敏感度100%,特异度95.4%。闪烁ERG振幅与初始视力无显著相关,与术后视力正相关。
要点
- RETeval闪烁ERG可用于密集玻璃体出血眼的功能评估。
- 振幅比诊断视网膜脱离的AUC为0.977,最佳截断值0.14。
- 闪烁ERG振幅与术后视力正相关,与初始视力无显著相关。
核心结论
- RETeval ERG系统在密集玻璃体出血妨碍眼底检查或后玻璃体脱离与视网膜脱离难以区分时是有用的诊断选择。
研究设计与样本
- 回顾性病例系列研究,纳入69眼(69例患者)急性密集玻璃体出血,用RETeval系统记录闪烁ERG。
主要发现
- 视网膜脱离患者振幅比极低(0.08 ± 0.03)。
- 检测视网膜脱离的AUC为0.977(95%CI 0.943-1.000),最佳截断值0.14,敏感度100.0%,特异度95.4%。
- 闪烁ERG振幅与初始视力无显著相关(ρ = -0.189,P = 0.120)。
- 闪烁ERG振幅与玻璃体出血眼术后视力正相关(ρ = -0.328,P = 0.006)。
关键数值与推荐
- 检测视网膜脱离的最佳振幅比截断值为0.14,敏感度100.0%,特异度95.4%。
临床怎么用
- 对密集玻璃体出血无法眼底检查或后玻璃体脱离与视网膜脱离难以鉴别时,可用RETeval闪烁ERG辅助评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To determine whether the RETeval electroretinography (ERG) system can be used to evaluate eyes with dense vitreous hemorrhage (VH). METHODS: This retrospective case series study included 69 eyes of 69 patients with acute dense VH. Flicker ERGs were recorded by the RETeval system, an ERG device with adhesive skin electrodes. We evaluated the flicker ERG amplitudes in eyes with VH and the ratio of the VH eye amplitudes compared with the fellow eye amplitudes for each VH cause. RESULTS: In patients with rhegmatogenous retinal detachment, the amplitude ratios were extremely low (0.08 ± 0.03). To detect rhegmatogenous retinal detachment, the area under the receiver operating characteristic curve was 0.977 (95% confidence interval, 0.943-1.000) (best rhegmatogenous retinal detachment cutoff value, 0.14; sensitivity, 100.0%; and specificity, 95.4%). The flicker ERG amplitude was not significantly correlated with the initial visual acuity (ρ = -0.189, P = 0.120) but was positively correlated with the postoperative visual acuity in eyes with VH (ρ = -0.328, P = 0.006). CONCLUSION: The RETeval ERG system was found to be a useful diagnostic option in situations where dense VH precluded fundus examination or posterior vitreous detachment was indistinguishable from rhegmatogenous retinal detachment.
引用
- Han KJ, Moon H, Woo JM, et al. USING RETeval SYSTEM FLICKER ELECTRORETINOGRAPHY FOR EVALUATION OF DENSE VITREOUS HEMORRHAGE. Retina. 2022. PMID: 34292221. doi:10.1097/IAE.0000000000003263
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。