增加黄斑测试位点能否提高青光眼黄斑视野缺损的检测?
在匹配特异度下,24-2+网格的簇检测能小幅提高黄斑缺损检出率,且未损失特异度,但测试时间延长21%。
要点
- 在匹配特异度下,24-2+网格较24-2网格的簇检测能检出更多黄斑缺损。
- 黄斑缺损检出率提升幅度约为5%至10%,不同偏差图和阈值下有所差异。
- 24-2+网格测试时间较24-2网格增加21%。
核心结论
- 使用额外黄斑位点的视野检查可在不损失特异度的情况下小幅提高青光眼性视神经病变黄斑缺损的检出。
主要发现
- 在匹配特异度下,24-2+网格的簇检测较24-2网格检出更多黄斑缺损。
- 5%总偏差图和模式偏差图的检出率平均提高8%(95%CI 5%-11%)和10%(95%CI 7%-13%)。
- 2%总偏差图和模式偏差图的检出率平均提高5%(95%CI 2%-7%)和6%(95%CI 4%-8%)。
- 两种网格间一致性良好,pAUC改善显著但通常较小,黄斑缺损眼百分比约为30%至50%。
- 24-2+网格测试时间延长21%,24-2网格漏诊的缺损中74%至98%至少有一个位点敏感度<20 dB。
关键数值与推荐
- 黄斑缺损定义为视野中央10°内总偏差或模式偏差图超出5%和2%正常限的位点。
- 分类基于受影响黄斑位点总数(总体检测)或最大连续簇的位点数(簇检测)。
- 使用健康队列的假检测计算特异度,并在95%或以上特异度下比较pAUC。
临床怎么用
- 在需要精细评估黄斑区缺损的青光眼患者中,可考虑使用24-2+网格以提高检出。
- 需注意24-2+网格测试时间较长,应权衡获益与效率。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate the ability of additional central testing locations to improve detection of macular visual field (VF) defects in glaucoma. DESIGN: Prospective cross-sectional study. PARTICIPANTS: Four hundred forty healthy people and 499 patients with glaucomatous optic neuropathy (GON) were tested with a fundus tracked perimeter (CMP; CenterVue) using a 24-2 grid with 12 additional macular locations (24-2+). METHODS: Glaucomatous optic neuropathy was identified based on expert evaluation of optic nerve head photographs and OCT scans, independently of the VF. We defined macular defects as locations with measurements outside the 5% and 2% normative limits on total deviation (TD) and pattern deviation (PD) maps within the VF central 10°. Classification was based on the total number of affected macular locations (overall detection) or the largest number of affected macular locations connected in a contiguous cluster (cluster detection). Criteria based on the number of locations and cluster size were used to obtain equivalent specificity between the 24-2 grid and the 24-2+ grids, calculated using false detections in the healthy cohort. Partial areas under the receiver operating characteristic curve (pAUCs) were also compared at specificities of 95% or more. MAIN OUTCOME MEASURES: Matched specificity comparison of the ability to detect glaucomatous macular defects between the 24-2 and 24-2+ grids. RESULTS: At matched specificity, cluster detection identified more macular defects with the 24-2+ grid compared with the 24-2 grid. For example, the mean increase in percentage of detection was 8% (95% confidence interval [CI], 5%-11%) and 10% (95% CI, 7%-13%) for 5% TD and PD maps, respectively, and 5% (95% CI, 2%-7%) and 6% (95% CI, 4%-8%) for the 2% TD and PD maps, respectively. Good agreement was found between the 2 grids. The improvement measured by pAUCs was also significant but generally small. The percentage of eyes with macular defects ranged from about 30% to 50%. Test time for the 24-2+ grid was longer (21% increase) for both cohorts. Between 74% and 98% of defects missed by the 24-2 grid had at least 1 location with sensitivity of < 20 dB. CONCLUSIONS: Visual field examinations with additional macular locations can improve the detection of macular defects in GON modestly without loss of specificity when appropriate criteria are selected.
引用
- Montesano G, McKendrick AM, Turpin A, et al. Do Additional Testing Locations Improve the Detection of Macular Perimetric Defects in Glaucoma? Ophthalmology. 2021. PMID: 34153384. doi:10.1016/j.ophtha.2021.06.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。