健康眼、青光眼可疑眼及青光眼眼中视盘周围血管密度的半视网膜不对称性
这项基于人群的横断面研究纳入1043只眼,用OCTA测量视盘周围毛细血管血管面积密度(VAD)并计算上下半视网膜VAD绝对差(hdVAD),发现hdVAD在轻度青光眼高于可疑眼、中度高于轻度、重度低于中度;hdVAD联合全局RNFL厚度对轻度青光眼和任何原发性开角型青光眼的诊断AUC最高。
要点
- hdVAD在健康眼与可疑眼间无显著差异(P=.225)。
- hdVAD联合gRNFL诊断轻度青光眼AUC为0.818,优于单一参数。
- hdVAD在重度青光眼诊断能力下降,因损伤呈弥漫性。
核心结论
- hdVAD在早期青光眼升高,可能有助于局灶性损伤的早期检测,但在晚期弥漫性损伤时诊断能力较弱。
研究设计与样本
- 基于人群的横断面研究,纳入1043名参与者的1043只眼(587健康、270可疑、67轻度、54中度、65重度青光眼)。
- 使用OCTA 6×6 mm视盘扫描获取VAD,OCT测量环视盘视网膜神经纤维层(RNFL)厚度。
- hdVAD定义为上半与下半视网膜VAD的绝对差值,采用年龄调整多变量线性回归分析hdVAD与青光眼严重程度的关系。
主要发现
- 年龄调整后,hdVAD均值在健康眼与可疑眼间相似(P=.225),轻度高于可疑(P<.001),中度高于轻度(P=.018),重度低于中度(P=.001)。
- hdVAD区分轻度与健康眼的AUC为0.685,区分中度与健康眼为0.681。
- hdVAD联合全局RNFL(gRNFL)诊断轻度青光眼AUC为0.818,诊断任何POAG为0.859,均显著优于单独hdVAD或gRNFL(所有比较P<.05)。
关键数值与推荐
- hdVAD在轻度青光眼高于可疑眼(P<.001),中度高于轻度(P=.018),重度低于中度(P=.001)。
- hdVAD诊断轻度青光眼AUC=0.685,中度=0.681。
- hdVAD+gRNFL诊断轻度青光眼AUC=0.818,任何POAG AUC=0.859。
临床怎么用
- 在早期青光眼评估中,可考虑将hdVAD与gRNFL联合使用以提高诊断准确性。
- hdVAD对晚期青光眼的诊断价值有限,需结合其他指标综合判断。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To investigate hemiretinal asymmetry in radial peripapillary capillary vessel area density (VAD) of healthy, glaucoma suspect, and glaucoma eyes of varying severity and its diagnostic utility for glaucoma. DESIGN: Population-based, cross-sectional study. METHODS: Optic disc scans (6 × 6 mm) were collected on optical coherence tomography angiography (OCTA) to obtain VAD and on optical coherence tomography (OCT) to measure circumpapillary retinal nerve fiber layer (RNFL) thickness. Hemiretinal difference in VAD (hdVAD) was defined as the absolute difference between superior and inferior hemiretinal VAD. Age-adjusted multivariable linear regression of hdVAD on glaucoma severity was performed. Areas under curves (AUCs) were calculated from predicted probabilities generated by multiple logistic regression of glaucoma severity on age-adjusted single and combined parameters. RESULTS: A total of 1,043 eyes of 1,043 participants (587 healthy, 270 suspect, 67 mild, 54 moderate, 65 severe glaucoma) were included. After age adjustment, mean hdVAD was similar between healthy and suspect (P = .225), higher in mild vs suspect (P < .001), and higher in moderate vs mild (P = .018), but lower in severe vs moderate (P = .001). AUCs of hdVAD were highest for discriminating mild (0.685) and moderate (0.681) glaucoma from healthy. Combining hdVAD and global RNFL (gRNFL) yielded the highest AUCs of all parameters for mild (0.818) and any POAG (0.859) and resulted in significantly better diagnostic accuracy than either hdVAD or gRNFL alone (P < .05 for all comparisons). CONCLUSIONS: hdVAD is higher in early glaucoma and may help with early detection when damage is focal, but its diagnostic ability appears less robust in advanced glaucoma when damage is diffuse.
引用
- Hong KL, Burkemper B, Urrea AL, et al. Hemiretinal Asymmetry in Peripapillary Vessel Density in Healthy, Glaucoma Suspect, and Glaucoma Eyes. Am J Ophthalmol. 2021. PMID: 34102157. doi:10.1016/j.ajo.2021.05.019
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。