算法与协变量在OCTA青光眼诊断中的影响
这项前瞻性横断面研究纳入36名正常对照和64名青光眼患者,用商业AngioAnalytics和自定义COOL-ART算法测量视盘周围NFLP-CD和黄斑SVC-VD。两种算法测得值高度相关但一致性差,诊断准确性无显著差异,且与结构OCT相当;年龄和信号强度是需要考虑的显著协变量,6mm黄斑区SVC-VD诊断准确性显著高于中央3mm区。
要点
- AngioAnalytics与COOL-ART血管密度测量不可互换但可能可相互转换。
- 年龄和信号强度是显著协变量,需在分析中调整。
- 两种算法及视盘周围与黄斑灌注参数的诊断准确性无显著差异,与结构OCT相当。
核心结论
- AngioAnalytics和COOL-ART血管密度测量不可互换但可能可相互转换。
- 年龄和信号强度是需考虑的显著协变量。
- 两种算法及视盘周围和黄斑灌注参数诊断准确性相似,与结构OCT相当。
- 更大的黄斑分析区域提供更高的诊断准确性。
研究设计与样本
- 前瞻性横断面研究,纳入36名正常对照和64名青光眼患者各一眼。
- 受试眼接受4.5mm视盘中心与6mm黄斑中心OCTA扫描。
- 用商业AngioAnalytics和自定义COOL-ART算法测量NFLP-CD和SVC-VD。
- 结构OCT测量神经纤维层和神经节细胞复合体厚度。
主要发现
- 两种算法测得的整体视盘周围NFLP-CD和黄斑SVC-VD高度相关但一致性差。
- 正常对照中两种算法灌注测量均与年龄显著相关。
- AngioAnalytics测量还与信号强度指数相关,COOL-ART测量则不然。
- 青光眼检测的AUC在两种算法间、结构与灌注参数间、视盘周围与黄斑区域间均无显著差异(所有p>0.05)。
- 6mm方形黄斑SVC-VD诊断准确性显著高于中央3mm方形区域(p=0.005)。
关键数值与推荐
- 两种算法间、结构与灌注参数间、视盘周围与黄斑区域间诊断AUC差异均无统计学意义(所有p>0.05)。
- 6mm方形黄斑SVC-VD诊断准确性显著高于中央3mm方形区域(p=0.005)。
临床怎么用
- 临床解读OCTA血管密度时需考虑年龄和信号强度的影响。
- 不同算法测得的血管密度值不可直接互换使用。
- 黄斑区分析可选择较大区域以提高青光眼诊断准确性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To assess the effects of algorithms and covariates in glaucoma diagnosis with optical coherence tomography angiography (OCTA). METHODS: In this prospective cross-sectional study, one eye each of 36 normal controls and 64 patients with glaucoma underwent 4.5 mm disc-centred and 6 mm macula-centred OCTA scans. The peripapillary nerve fibre layer plexus capillary density (NFLP-CD) and macular superficial vascular complex vessel density (SVC-VD) were measured using both a commercial algorithm (AngioAnalytics) and a custom algorithm (Center for Ophthalmic Optics & Lasers Angiography Reading Toolkit (COOL-ART)). The nerve fibre layer and ganglion cell complex thicknesses were measured on structural OCT. RESULTS: The overall peripapillary NFLP-CD and macular SVC-VD measured with the two algorithms were highly correlated but poorly agreed. Among the normal controls, the perfusion measurements made by both algorithms were significantly correlated with age. AngioAnalytics measurements were also correlated with signal strength index, while COOL-ART measurements were not. These covariates were adjusted. The diagnostic accuracy, measured as the area under the receiver operating characteristic curve for glaucoma detection, was not significantly different between algorithms, between structural and perfusion parameters and between the peripapillary and macular regions (All p>0.05). The macular SVC-VD in the 6 mm square had a significantly higher diagnostic accuracy than that of the central 3 mm square area (p=0.005). CONCLUSIONS: AngioAnalytics and COOL-ART vessel density measurements are not interchangeable but potentially interconvertible. Age and signal strength are significant covariates that need to be considered. Both algorithms and both peripapillary and macular perfusion parameters have similarly good diagnostic accuracy comparable to structural OCT. A larger macular analytic area provides higher diagnostic accuracy.