27G镊辅助经巩膜复位脱位CZ70BD人工晶状体新技术

Novel Technique for 27-Gauge Forceps-Assisted Transscleral Refixation of the Dislocated CZ70BD Intraocular Lens.
PubMed 文献 · Retina · 2023-01-01

本文报告一种经巩膜复位脱位CZ70BD人工晶状体的新技术,采用23G或25G玻璃体切除联合吊灯照明,以27G针头将9-0 Prolene缝线经角膜穿刺口引出,再用27G MaxGrip镊在玻璃体腔内将缝线穿过晶状体耳孔并固定于巩膜。7眼手术成功,平均随访12.4个月,最佳矫正视力显著改善(P=0.016),晶状体居中良好,1眼术后1个月发生黄斑在位视网膜脱离并成功修复。

要点

  • 27G镊辅助经巩膜缝线固定可有效复位脱位的CZ70BD人工晶状体。
  • 7眼术后最佳矫正视力显著改善(P=0.016),晶状体居中满意。
  • 1眼术后1个月发生黄斑在位视网膜脱离,修复后视力无下降。

核心结论

  • 该27G镊辅助经巩膜复位技术对脱位CZ70BD人工晶状体有效。

研究设计与样本

  • 回顾性病例系列,共7眼接受该新技术手术,平均随访12.4个月。

主要发现

  • 7眼均成功手术,术后最佳矫正视力显著改善(P=0.016)。
  • 术后人工晶状体居中和位置满意。
  • 1眼术后1个月发生黄斑在位视网膜脱离,成功修复且最佳矫正视力无下降。

临床怎么用

  • 对脱位CZ70BD人工晶状体可采用27G镊辅助经巩膜缝线固定进行复位。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To report a novel technique for refixation of the dislocated CZ70BD intraocular lens. METHODS: Posterior vitrectomy is performed with a 23-gauge or 25-gauge pars plana vitrectomy system with chandelier illumination. One needle of a double-arm 9-0 prolene needle is passed through the sclera 1.5 mm postlimbus. The needle is retrieved through the corneal paracentesis using a 27-G needle, and the suture is then cut. The suture end is passed through the eyelet of the dislocated CZ70BD intraocular lens inside the vitreous cavity. This is aided with a pair of 27-G MaxGrip forceps, which is inserted through a 27-G sclerostomy site at the intended scleral outlet. After passing the suture through the eyelet, the suture is pulled out at the 27-G sclerostomy site and a knot is tied and rotated. Similar procedure is performed for the second haptic if necessary. RESULTS: Seven eyes were successfully operated on using this technique with a mean follow-up of 12.4 months. There was significant improvement in the best-corrected visual acuity after the operation ( P = 0.016). Postoperative intraocular lens centration and alignment were satisfactory. One patient developed macula-on retinal detachment 1 month after the operation, which was successfully repaired without loss in the best-corrected visual acuity. CONCLUSION: The described novel technique is effective for refixation of dislocated CZ70BD intraocular lens.

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Yip LT, Fong A, Tsang CW, et al. Novel Technique for 27-Gauge Forceps-Assisted Transscleral Refixation of the Dislocated CZ70BD Intraocular Lens. Retina. 2023. PMID: 34081639. doi:10.1097/IAE.0000000000003225

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。