文献速递眼底病与葡萄膜炎

新型可拆除聚丙烯8.0缝线用于23G玻璃体切割术巩膜切口封闭

New Releasable Nonabsorbable Polypropylene 8.0 Suturing Technique for Sclerotomy Sealing in 23-Gauge Vitrectomy.
PubMed 文献 · Retina · 2023-01-01

研究提出一种用于玻璃体切割术毕渗漏巩膜切口的可拆除8.0聚丙烯缝线,术后次日可在裂隙灯下拆除。连续纳入需至少2个巩膜切口缝线且术前OSDI评分<12的23G玻璃体切割术患者,分为可吸收缝线组与可拆除聚丙烯缝线组。两种方法均有效封闭巩膜切口,聚丙烯组术后7天和30天OSDI评分及结膜充血程度均更低。

要点

  • 可拆除8.0聚丙烯缝线可有效封闭23G玻璃体切割术巩膜切口。
  • 与聚乳酸910可吸收缝线相比,聚丙烯组术后7天和30天OSDI评分更低。
  • 聚丙烯组术后7天和30天结膜充血程度均低于可吸收缝线组。

核心结论

  • 8.0聚丙烯可拆除缝线能有效封闭23G玻璃体切割术巩膜切口,且较标准聚乳酸910缝线引起更少的眼表炎症和患者不适。

研究设计与样本

  • 连续纳入需至少2个巩膜切口缝线且术前OSDI评分<12的23G玻璃体切割术患者,分为聚乳酸910可吸收缝线组和8.0聚丙烯可拆除缝线组。

主要发现

  • 两种方法均有效封闭巩膜切口。
  • 聚丙烯组术后7天和30天OSDI评分显著低于聚乳酸910组。
  • 聚丙烯组OSDI评分术后7天显著下降,而聚乳酸910组术后30天才改善。
  • 聚丙烯组术后7天和30天结膜充血程度均低于聚乳酸910组。

关键数值与推荐

  • 纳入标准为术前OSDI评分<12且需至少2个巩膜切口缝线。
  • 术后1天、7天和30天评估不良事件、OSDI评分及Efron量表结膜充血。

临床怎么用

  • 对23G玻璃体切割术毕渗漏巩膜切口,可选用8.0聚丙烯可拆除缝线,术后次日裂隙灯下拆除。
  • 该缝线可能减少术后眼表炎症和患者不适,尤其适用于关注眼表状态的患者。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: We propose a new releasable 8.0 polypropylene suture for leaking sclerotomies at the end of vitrectomy. Characteristic of this suture is that it can be easily removed the day after surgery at the slit-lamp examination. METHODS: Patients undergoing 23-gauge pars plana vitrectomy with the need for at least 2 sclerotomy sutures and having a preoperative Ocular Surface Disease Index score <12 were consecutively allocated to sealing with either polyglactin 910 absorbable suture (VY GROUP) or nonabsorbable 8.0 polypropylene releasable suture (PR GROUP). Evaluation of adverse events, Ocular Surface Disease Index score, and conjunctival hyperemia (through the Efron scale) was performed at 1, 7, and 30 days postoperatively. RESULTS: Both methods effectively sealed sclerotomies. PR GROUP showed a significantly lower Ocular Surface Disease Index score and lower degree of conjunctival hyperemia at both 7 and 30 days follow-up. The Ocular Surface Disease Index score decreased significantly after 7 days in PR GROUP while in VY GROUP improved at 30 days postoperatively. PR GROUP showed a lower degree of conjunctival hyperemia both at 7 and 30 days follow-up. CONCLUSION: Polypropylene 8-0 releasable sutures proved to be effective in 23-gauge pars plana vitrectomy wound sealing while inducing less ocular surface inflammation and patient discomfort compared with the standard polyglactin 910 suture.

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Savastano A, Crincoli E, Caporossi T, et al. New Releasable Nonabsorbable Polypropylene 8.0 Suturing Technique for Sclerotomy Sealing in 23-Gauge Vitrectomy. Retina. 2023. PMID: 34009184. doi:10.1097/IAE.0000000000003213

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。