文献速递眼底病与葡萄膜炎青光眼

中国成人视盘及视盘周围血管密度OCTA大样本研究

Optic disc and peripapillary vessel density measured with optical coherence tomography angiography and its associations in Chinese adults: a large population-based study.
PubMed 文献 · Br J Ophthalmol · 2021-05-20

该研究基于香港中国成人人群横断面调查,纳入1487名参与者(1487眼),使用4.5×4.5 mm OCTA扫描测量视盘及视盘周围神经纤维层丛血管密度,发现全区域、视盘内及视盘周围NFLP VD均值分别为53.8%、42.7%和60.3%,并揭示年龄、性别、眼轴长度及信号强度指数与VD的独立关联。

要点

  • 中国成人NFLP VD正常参考值:全区域53.8%,视盘内42.7%,视盘周围60.3%。
  • 年龄增长、男性、眼轴延长及信号强度指数降低与NFLP VD下降显著相关。
  • 评估NFLP VD时需考虑扫描信号强度的影响。

核心结论

  • 该大样本人群横断面研究提供了中国成人视盘及视盘周围NFLP VD的定量数据,可作为临床参考标准。
  • 除年龄、性别和眼轴长度外,扫描信号强度也应在评估NFLP VD时予以考虑。

研究设计与样本

  • 基于香港中国成人的人群横断面眼病调查,共纳入1891眼(1891名参与者)完成4.5×4.5 mm OCTA扫描,排除404眼后最终分析1487眼(1487名参与者)。

主要发现

  • 最终纳入1487名参与者(男性占41.2%),平均年龄48.8±15.4岁。
  • 全脸面图像、视盘内及视盘周围区域的平均NFLP VD分别为53.8%、42.7%和60.3%。
  • 多变量模型显示,NFLP VD降低与年龄较大、男性、眼轴较长及信号强度指数较低显著相关。

关键数值与推荐

  • 全脸面图像NFLP VD均值53.8%,视盘内42.7%,视盘周围60.3%。
  • 多变量模型纳入年龄、性别、眼轴长度及信号强度指数等变量。

临床怎么用

  • 临床解读OCTA测量的视盘及视盘周围NFLP VD时,可参考本研究提供的中国成人正常值范围。
  • 判读时应结合年龄、性别、眼轴长度及扫描信号强度指数综合评估,避免误判。

局限性

  • 本研究为横断面设计,无法确定因果关系。
  • 排除低扫描质量、视盘或视网膜疾病及非华裔人群后,结果外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To investigate the optic disc and peripapillary vessel density, as well as its ocular and systemic associations, in healthy eyes among adult Chinese population. METHODS: A population-based cross-sectional eye survey was conducted on Chinese adults residing in Hong Kong. 1891 eyes from 1891 participants who completed 4.5×4.5 mm optical coherence tomography angiography scans were recruited. Among the 1891 eyes, 404 were excluded due to low scan quality, optic disc or retinal disorders and non-Chinese ethnicity. The vessel densities (VDs) at nerve fibre layer plexus (NFLP) at both optic disc and peripapillary were collected for analysis. Multiple linear regression analysis was performed to determine the ocular and systemic associations of NFLP VD. RESULTS: The study included 1487 participants (men: 41.2%) with a mean age of 48.8±15.4 years. The mean NFLP VD of the whole en face image, inside disc and peripapillary region was 53.8%, 42.7% and 60.3%, respectively. In the multivariable model, decreased NFLP VDs were significantly associated with older age, male gender, longer axial length (AL) and lower Signal Strength Index. CONCLUSIONS: This large population-based cross-sectional study provided quantitative data of optic disc and peripapillary NFLP VD which may serve as a normative reference for clinical use. Apart from age, gender and AL, the scan signal strength also should be taken into consideration during the assessment of NFLP VD.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Zhu MM, Choy BNK, You QS, et al. Optic disc and peripapillary vessel density measured with optical coherence tomography angiography and its associations in Chinese adults: a large population-based study. Br J Ophthalmol. 2021. PMID: 34016574. doi:10.1136/bjophthalmol-2020-318199

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。