文献速递青光眼神经眼科

青光眼中L视锥和M视锥对比度在视网膜膝状体系统的总和

Summation of Temporal L-Cone- and M-Cone-Contrast in the Magno- and Parvocellular Retino-Geniculate Systems in Glaucoma.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2021-01-01

该研究采用三重静默替换法测量73名受试者(13名健康者、25名青光眼患者、35名视野前期青光眼患者)的黄斑周围时间对比敏感度,分析L和M视锥对比度在P通路和M通路中的总和。结果发现低频由P通路介导、高频由M通路介导,相位角在诊断组间无显著差异;仅M通路中L视锥驱动的时间对比敏感度偏差在青光眼患者中显著降低,并与视野平均缺损和视网膜神经纤维层厚度相关。

要点

  • 低频感知由P通路介导,L/M视锥输入强度平衡;高频由M通路介导,输入强度不平衡。
  • 青光眼患者M通路中20 Hz L视锥驱动的时间对比敏感度偏差显著降低。
  • 该偏差与视野平均缺损线性相关,与视网膜神经纤维层厚度二次相关。

核心结论

  • 青光眼中L和M视锥输入间的相位角未改变,提示时间处理完整。
  • 仅在M通路中,对比敏感度偏差与诊断组、视野平均缺损和视网膜神经纤维层厚度密切相关,提示M通路受累。

研究设计与样本

  • 横断面研究,共纳入73名受试者:13名健康者、25名青光眼患者、35名视野前期青光眼患者。
  • 使用三重静默替换法测量黄斑周围对孤立或组合L和M视锥对比度的时间对比敏感度,频率为1或2 Hz和20 Hz。
  • 采用矢量总和模型分析感知由P通路、M通路或两者驱动,并估计L和M视锥输入强度(AL、AM)及相位差。

主要发现

  • 低频感知始终由P通路介导,中位相位角179.84度(视锥拮抗),中位AL/AM比值1.04(L和M视锥输入强度平衡)。
  • 高频感知仅由M通路介导,输入强度不平衡:AL/AM=2.94,中位相位角130.17度。
  • 相位差在诊断组间无显著差异(Kruskal-Wallis检验P通路0.092,M通路0.35)。
  • 仅M通路发现组间差异:青光眼患者20 Hz L视锥时间对比敏感度偏差显著降低(P=0.014),M视锥有强烈趋势(P=0.049)。
  • 20 Hz L视锥驱动的对比敏感度偏差与视野平均缺损线性相关,与视网膜神经纤维层厚度二次相关。

临床怎么用

  • M通路时间对比敏感度偏差可能作为青光眼功能损伤的客观指标,尤其与视野平均缺损和视网膜神经纤维层厚度相关。
  • 相位角在青光眼中保持稳定,提示时间处理完整,或可用于鉴别其他视神经病变。

局限性

  • 样本量有限,分组人数不等。
  • 未报告纵向随访数据,无法确定因果关系。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The purpose of this study was to characterize summation of temporal L- and M-cone contrasts in the parvo- (P-) and magnocellular (M-) pathways in glaucoma and the relationship between the respective temporal contrast sensitivities (tCS) and clinical parameters. METHODS: Perifoveal tCS to isolated or combined L- and M-cone contrasts (with different contrast ratios, and therefore different luminance and chromatic components) were measured at different temporal frequencies (at 1 or 2 Hz and at 20 Hz) using triple silent substitution in 73 subjects (13 healthy, 25 with glaucoma, and 35 with perimetric glaucoma). A vector summation model was used to analyze whether perception was driven by the P-pathway, the M-pathway, or both. Using this model, L- and M-cone input strengths (AL, AM) and phase differences between L- and M-cone inputs were estimated. RESULTS: Perception was always mediated by the P-pathway at low frequencies, as indicated by a median phase angle of 179.84 degrees (cone opponency) and a median AL/AM ratio of 1.04 (balanced L- and M-cone input strengths). In contrast, perception was exclusively mediated by the M-pathway at higher frequencies (input strength not balanced: AL/AM = 2.94, median phase angles = 130.17 degrees). Differences in phase were not significant between diagnosis groups (Kruskal-Wallis = 0.092 for P- and 0.35 for M-pathway). We found differences between groups only for the M-pathway (L-cone tCS deviations at 20 Hz were significantly lower in the patients with glaucoma P = 0.014, with a strong tendency in M-cones P = 0.049). L-cone driven tCS deviations at 20 Hz were linearly correlated with perimetric mean defect (MD) and quadratically correlated with retinal nerve fiber layer (RNFL) thickness. CONCLUSIONS: Unaltered phase angles between L- and M-cone inputs in glaucoma indicated intact temporal processing. Only in the M-pathway, contrast sensitivity deviations were closely related to diagnosis group, MD, and RNFL thickness, indicating M-pathway involvement.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Huchzermeyer C, Horn F, Lämmer R, et al. Summation of Temporal L-Cone- and M-Cone-Contrast in the Magno- and Parvocellular Retino-Geniculate Systems in Glaucoma. Invest Ophthalmol Vis Sci. 2021. PMID: 33988692. doi:10.1167/iovs.62.6.17

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。