文献速递眼底病与葡萄膜炎角膜与眼表疾病

干眼症患者泪膜破裂时间对OCTA黄斑微血管测量重复性的影响

REPEATABILITY OF MACULAR MICROVASCULATURE MEASUREMENTS USING OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY ACCORDING TO TEAR BREAKUP TIME IN DRY EYE DISEASE.
PubMed 文献 · Retina · 2021-01-01

本研究按泪膜破裂时间(TBUT)将干眼症患者分为三组,比较OCTA测量黄斑微血管的重复性。结果显示TBUT≤5秒组信号强度较低,血管密度ICC为0.733,变异系数和重测SD均较高,提示TBUT越短OCTA重复性越差,TBUT<5秒时需谨慎解读OCTA结果。

要点

  • TBUT≤5秒组OCTA信号强度为9.1±1.2,显著低于其他两组(P=0.049)。
  • 血管密度ICC随TBUT缩短而降低:三组分别为0.733、0.840、0.974。
  • TBUT≤5秒时OCTA重复性明显下降,解读结果需谨慎。

核心结论

  • OCTA重复性随TBUT缩短而呈下降趋势,TBUT<5秒时需注意正确解读OCTA结果。

研究设计与样本

  • 将干眼症眼按TBUT分为三组:组1(TBUT≤5秒,43眼)、组2(5秒<TBUT≤10秒,35眼)、组3(TBUT>10秒,34眼),每组行两次3×3 OCTA检查。

主要发现

  • 三组OCTA信号强度分别为9.1±1.2、9.5±0.8、9.5±0.8,差异有统计学意义(P=0.049)。
  • 血管密度ICC在组1至组3分别为0.733、0.840、0.974,按组1、2、3顺序递增。
  • 变异系数在组1至组3分别为6.41±6.09、3.29±2.22、1.30±1.17,按组1、2、3顺序递减,差异有统计学意义(均P<0.05)。
  • 重测SD在组1至组3分别为0.83±0.70、0.47±0.31、0.19±0.17,按组1、2、3顺序递减,差异有统计学意义(均P<0.05)。

临床怎么用

  • 对TBUT<5秒的干眼症患者,解读OCTA黄斑微血管结果时应考虑重复性降低的影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: It is hypothesized that an unstable tear film would affect the quality and repeatability of optical coherence tomography angiography (OCTA). Therefore, OCTA repeatability according to tear break-up time (TBUT) was compared. METHODS: The 3 × 3 OCTA was performed twice and, the eyes were divided into 3 groups according to the TBUT (Group 1: TBUT ≤ 5 seconds, 43 eyes; Group 2: 5 seconds < TBUT ≤ 10 seconds, 35 eyes; Group 3: TBUT > 10 seconds, 34 eyes). The intraclass correlation coefficient, coefficient of variation, and test-retest SD were calculated and compared. RESULTS: The signal strengths of OCTA were 9.1 ± 1.2, 9.5 ± 0.8, and 9.5 ± 0.8 in each group from Groups 1, 2, and 3, respectively, which showed significant difference (P = 0.049). The intraclass correlation coefficient of vessel density were 0.733, 0.840, and 0.974 in Groups 1 to 3, respectively, and the values increased in the order of Groups 1, 2, and 3. The coefficient of variation were 6.41 ± 6.09, 3.29 ± 2.22, and 1.30 ± 1.17, and the test-retest SD were 0.83 ± 0.70, 0.47 ± 0.31, and 0.19 ± 0.17 in Groups 1, 2, and 3, respectively. The coefficient of variation and test-retest SD values decreased in the order of Groups 1, 2, and 3, and showed a significant difference (all, P < 0.05). CONCLUSION: The repeatability of OCTA tended to decrease with a shorter TBUT. When the TBUT is <5 seconds, care must be taken to interpret the OCTA results correctly.

来源:Retina,查看原文。版权归原作者所有。