文献速递角膜与眼表疾病白内障与屈光手术

高度近视三种角膜屈光术后角膜神经修复与光密度比较

[Corneal nerve repair and optical density in patients with high myopia after three kinds of corneal refractive surgery].
PubMed 文献 · Zhonghua Yan Ke Za Zhi · 2021-01-01

队列研究纳入30例(60眼)高度近视患者,比较SMILE、FS-LASIK与LASEK术后12个月角膜上皮下神经修复及角膜光密度。结果显示SMILE上方切口周围神经修复略差于另两组,但其他区域有优势且角膜透明度更佳。

要点

  • 术后12个月三组角膜各区域CNFD差异均无统计学意义。
  • LASEK组上方切口周围CNBD和CTBD显著高于SMILE和FS-LASIK组。
  • SMILE组CNFL显著低于FS-LASIK和LASEK组,但角膜光密度更低。

核心结论

  • 高度近视SMILE术后12个月上方角膜切口周围神经修复略差于FS-LASIK和LASEK,但其他区域神经修复有一定优势,且角膜透明度更佳。

研究设计与样本

  • 队列研究,纳入2018年6月至2019年10月青岛大学附属医院眼科高度近视(等效球镜6.00~10.00 D)患者30例60眼,女性16例32眼、男性14例28眼,年龄(22.46±3.15)岁。
  • 按手术方式分为SMILE组10例、FS-LASIK组11例、LASEK组9例。
  • 术后12个月用激光共聚焦显微镜观察角膜上皮下神经,ACCMetrics软件分析CNFD、CNBD、CNFL、CTBD和CNFW。
  • 用Pentacam眼前节分析仪检测角膜不同直径范围光密度。
  • 组间比较采用随机区组方差分析,多重比较采用Turkey HSD检验。

主要发现

  • 术后12个月三组角膜各区域CNFD差异均无统计学意义(P>0.05)。
  • SMILE组、FS-LASIK组及LASEK组上方角膜切口周围CNBD分别为(7.81±7.93)、(9.61±7.18)、(21.25±15.55)个/mm²。
  • 三组CTBD分别为(22.00±16.02)、(24.44±11.42)、(54.37±22.13)个/mm²,LASEK组与其他两组差异均有统计学意义(HSD=2.823,-3.010,3.053,-3.048;P<0.01)。
  • 三组CNFL分别为(9.19±3.25)、(12.88±3.52)、(15.75±2.36)mm/mm²,SMILE组与其他两组差异有统计学意义(HSD=-3.151,-4.418;P<0.01)。
  • SMILE术后直径12 mm内角膜光密度为14.06±1.36,低于其他两种术式(HSD=-6.031,-5.519;P<0.01)。

关键数值与推荐

  • 高度近视定义为近视等效球镜度数6.00~10.00 D。
  • 术后12个月SMILE组上方切口周围CNBD为(7.81±7.93)个/mm²,FS-LASIK组为(9.61±7.18)个/mm²,LASEK组为(21.25±15.55)个/mm²。
  • 术后12个月SMILE组CTBD为(22.00±16.02)个/mm²,FS-LASIK组为(24.44±11.42)个/mm²,LASEK组为(54.37±22.13)个/mm²。
  • 术后12个月SMILE组CNFL为(9.19±3.25)mm/mm²,FS-LASIK组为(12.88±3.52)mm/mm²,LASEK组为(15.75±2.36)mm/mm²。
  • SMILE术后直径12 mm内角膜光密度为14.06±1.36,低于FS-LASIK和LASEK组(HSD=-6.031,-5.519;P<0.01)。

临床怎么用

  • 高度近视行SMILE术后上方切口周围神经修复可能略慢于FS-LASIK和LASEK,临床随访可关注该区域神经状态。
  • SMILE术后其他区域神经修复及角膜透明度可能具有一定优势,可用于术前沟通参考。
  • 角膜光密度作为透明度指标,可用于评估不同屈光术后角膜 transparency 差异。

局限性

  • 样本量较小,SMILE组10例、FS-LASIK组11例、LASEK组9例。
  • 仅观察术后12个月单一时点,缺乏更长期随访数据。
  • 原文未报告其他局限性信息。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Objective: To investigate the repair of subepithelial nerve fibers in different areas of the cornea and the difference of corneal transparency 12 months after small incision lenticule extraction (SMILE), femtosecond laser in situ keratomileusis (FS-LASIK) and excimer laser in situ keratomileusis (LASEK) in high myopia. Methods: A cohort study. From June 2018 to October 2019, 30 patients with high myopia (60 eyes) were selected for corneal refractive surgery in the Department of Ophthalmology, Affiliated Hospital of Qingdao University, including 16 females (32 eyes) and 14 males (28 eyes). According to the mode of operation, the patients were divided into the SMILE group (n=10), FS-LASIK group (n=11) and LASEK group (n=9). The repair of subepithelial nerves in different areas of the cornea was observed by laser confocal microscopy 12 months after operation,and the morphological parameters were analyzed by ACCMetrics software. The parameters included corneal nerve fiber density (CNFD), corneal nerve branch density (CNBD), corneal nerve fiber length (CNFL), corneal nerve fiber total branch density (CTBD) and corneal nerve fiber width. The Pentacam anterior segment analyzer was used to measure the optical density of the cornea in different diameters. The nerve fiber parameters and corneal optical density were compared by random block analysis of variance, and multiple comparisons were performed between groups by the Turkey test. Results: Twelve months after operation, there was no significant difference in the CNFD among the three groups(all P>0.05). The CNBD around the upper corneal incision in the SMILE group, FS-LASIK group and LASEK group was (7.81±7.93), (9.61±7.18) and (21.25±15.55) branches/mm2, respectively. The CTBD was (22.00±16.02), (24.44±11.42) and (54.37±22.13) branches/mm2, respectively. The values in the LASEK group significantly differed from the other two groups (HSD=2.823, -3.010, 3.053, -3.048, P<0.01). The CNFL was (9.19±3.25), (12.88±3.52) and (15.75±2.36) mm/mm2, respectively. The value in the SMILE group was significantly different (HSD=-3.151, -4.418; P<0.0l). The corneal optical density after SMILE was 13.16±0.72 in the 0-6 mm diameter area(HSD=-4.164, -4.489; P<0.01), 16.12±3.18 in the 6-12 mm diameter area(HSD=-3.918, -3.493;P<0.01) and 14.06±1.36 in the total diameter (HSD=-6.031, -5.519;P<0.01), which differed significantly from the other two groups. Conclusions: Twelve months after SMILE for high myopia, the nerve repair around the superior corneal incision is slightly worse than that after FS-LASIK and LASEK, but the nerve repair in other areas has some advantages, and the corneal transparency is better. (Chin J Ophthalmol, 2021, 57:268-276). 目的: 探讨高度近视眼行飞秒激光小切口角膜基质透镜取出术(SMILE)、飞秒激光制瓣的准分子激光原位角膜磨镶术(FS-LASIK)及准分子激光上皮瓣下角膜磨镶术(LASEK)术后12个月角膜不同区域上皮下神经的修复情况和角膜透明度的差异。 方法: 队列研究。收集于2018年6月至2019年10月在山东省青岛大学附属医院眼科就诊并进行角膜屈光手术的高度近视眼(近视等效球镜度数6.00~10.00 D)患者30例(60只眼),其中女性16例(32只眼),男性14例(28只眼);年龄(22.46±3.15)岁,按手术方式分为SMILE组(10例)、FS-LASIK组(11例)、LASEK组(9例),于术后12个月在激光共聚焦显微镜下观察角膜不同区域上皮下神经的修复情况,并通过ACCMetrics软件分析其形态学参数,包括神经纤维密度(CNFD)、主要神经分叉节点密度(CNBD)、神经纤维长度(CNFL)、总神经分叉节点密度(CTBD)和神经纤维宽度(CNFW);采用Pentacam眼前节分析仪对角膜不同直径范围内的光密度进行检测。各组间神经形态学参数、角膜光密度的比较采用随机区组方差分析,组间多重比较采用Turkey真实显著差(HSD)检验。 结果: 术后12个月,3种术式角膜各区域内的CNFD差异均无统计学意义(P>0.05)。SMILE组、FS-LASIK组及LASEK组上方角膜切口周围的CNBD分别为(7.81±7.93)、(9.61±7.18)、(21.25±15.55)个/mm2;CTBD分别为(22.00±16.02)、(24.44±11.42)、(54.37±22.13)个/mm2,LASEK组与其他两组相比,差异均有统计学意义(HSD=2.823,-3.010,3.053,-3.048;P<0.01);3个组CNFL分别为(9.19±3.25)、(12.88±3.52)、(15.75±2.36)mm/mm2,SMILE组与其他两组相比,差异有统计学意义(HSD=-3.151,-4.418;P<0.01)。SMILE术后直径12 mm内角膜的光密度为14.06±1.36,低于其他2种术式(HSD=-6.031,-5.519;P<0.01)。 结论: 高度近视眼行SMILE术后12个月,角膜上方切口周围的神经修复情况略差于FS-LASIK和LASEK,但其他区域的神经修复情况存在一定的优势;SMILE术后角膜透明度更佳。(中华眼科杂志,2021,57:268-276).

来源:Zhonghua Yan Ke Za Zhi,查看原文。版权归原作者所有。

引用

  1. Li JF, Hou CT, Li JJ, et al. [Corneal nerve repair and optical density in patients with high myopia after three kinds of corneal refractive surgery]. Zhonghua Yan Ke Za Zhi. 2021. PMID: 33832051. doi:10.3760/cma.j.cn112142-20200612-00394

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。