PubMed 文献 · Br J Ophthalmol · 2021-04-09

研究纳入4806例白内障患者数据,训练集5761眼、测试集961眼,用机器学习预测术后前房深度并修正四种人工晶状体计算公式的有效晶状体位置。测试集显示四种公式的屈光预测平均绝对误差均显著降低(p<0.05)。

要点

  • 机器学习预测术后前房深度可替换或线性组合原有有效晶状体位置。
  • Haigis、Hoffer Q、Holladay和SRK/T公式的屈光预测MAE均显著降低。
  • 测试集MAE:Haigis 0.356±0.329 D,Hoffer Q 0.352±0.319 D。

核心结论

  • 使用更准确预测的术后前房深度可显著提升四种现有人工晶状体度数公式的预测准确性。

研究设计与样本

  • 回顾性数据集研究,纳入4806例白内障患者,分为训练集(5761眼)和测试集(961眼)。
  • 用机器学习基于术前生物测量预测术后前房深度,并通过回归模型将ML输出缩放整合到四种公式的有效晶状体位置中。

主要发现

  • 测试集中,ML修正ELP后Haigis公式屈光预测MAE±SD为0.356±0.329 D。
  • Hoffer Q公式MAE±SD为0.352±0.319 D,Holladay为0.371±0.336 D,SRK/T为0.361±0.331 D。
  • 上述MAE均显著低于原公式:Haigis 0.373±0.328 D、Hoffer Q 0.408±0.337 D、Holladay 0.384±0.341 D、SRK/T 0.394±0.351 D(p<0.05)。

关键数值与推荐

  • ML修正ELP采用原ELP与ML预测ELP的线性组合。
  • 性能以屈光预测的平均绝对误差(MAE)衡量。

临床怎么用

  • 在现有IOL计算公式中整合ML预测的术后前房深度,可降低屈光预测误差。
  • 该方法适用于Haigis、Hoffer Q、Holladay和SRK/T四种公式的ELP修正。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: To assess whether incorporating a machine learning (ML) method for accurate prediction of postoperative anterior chamber depth (ACD) improves the refraction prediction performance of existing intraocular lens (IOL) calculation formulas. METHODS: A dataset of 4806 patients with cataract was gathered at the Kellogg Eye Center, University of Michigan, and split into a training set (80% of patients, 5761 eyes) and a testing set (20% of patients, 961 eyes). A previously developed ML-based method was used to predict the postoperative ACD based on preoperative biometry. This ML-based postoperative ACD was integrated into new effective lens position (ELP) predictions using regression models to rescale the ML output for each of four existing formulas (Haigis, Hoffer Q, Holladay and SRK/T). The performance of the formulas with ML-modified ELP was compared using a testing dataset. Performance was measured by the mean absolute error (MAE) in refraction prediction. RESULTS: When the ELP was replaced with a linear combination of the original ELP and the ML-predicted ELP, the MAEs±SD (in Diopters) in the testing set were: 0.356±0.329 for Haigis, 0.352±0.319 for Hoffer Q, 0.371±0.336 for Holladay, and 0.361±0.331 for SRK/T which were significantly lower (p<0.05) than those of the original formulas: 0.373±0.328 for Haigis, 0.408±0.337 for Hoffer Q, 0.384±0.341 for Holladay and 0.394±0.351 for SRK/T. CONCLUSION: Using a more accurately predicted postoperative ACD significantly improves the prediction accuracy of four existing IOL power formulas.