文献速递青光眼神经眼科

体位依赖性视神经蛛网膜下腔塌陷:MRI与建模联合研究

Posture-Dependent Collapse of the Optic Nerve Subarachnoid Space: A Combined MRI and Modeling Study.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2021-01-01

研究对6名健康志愿者行6°头低位与13°头高位MRI,发现视神经蛛网膜下腔(ONSAS)体积下降33%(P < 0.001)。结合数学建模模拟90°直立位,预测筛板后25 mm处ONSAS塌陷,使体位性筛板跨压力差(TLCPD)增加减少约1 mm Hg,但该效应高度依赖视神经鞘可扩张性,在±1 SD变化下介于0与4.8 mm Hg。

要点

  • 从6°头低位到13°头高位,ONSAS体积下降33%(P < 0.001)。
  • 模拟直立位预测筛板后25 mm处ONSAS塌陷,阻断与颅内蛛网膜下腔的压力沟通。
  • 塌陷使模拟TLCPD体位性增加减少约1 mm Hg,但受视神经鞘可扩张性影响大。

核心结论

  • 视神经蛛网膜下腔体积随体位变化,直立位模拟支持ONSAS塌陷并可能减小TLCPD。

研究设计与样本

  • 对6名健康志愿者行6°头低位与13°头高位MRI测量ONSAS体积,并结合数学建模模拟90°直立位。

主要发现

  • MRI显示从6°头低位到13°头高位ONSAS体积下降33%(P < 0.001)。
  • 模拟90°直立位预测筛板后25 mm处ONSAS塌陷,中断ONSAS与颅内蛛网膜下腔的压力沟通。
  • 塌陷使模拟TLCPD的体位性增加减少约1 mm Hg,视神经鞘可扩张性±1 SD变化时该减少量介于0与4.8 mm Hg。

临床怎么用

  • 提示评估颅内压与眼压相关疾病时需考虑体位对ONSAS体积及TLCPD的影响。
  • 视神经鞘刚度/可扩张性个体差异可能显著影响TLCPD,临床解读需谨慎。

局限性

  • MRI仅纳入6名健康志愿者,样本量小。
  • 直立位ONSAS塌陷及TLCPD变化为数学模拟预测,非直接测量。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: We hypothesize that a collapse of the optic nerve subarachnoid space (ONSAS) in the upright posture may protect the eyes from large translamina cribrosa pressure differences (TLCPD) believed to play a role in various optic nerve diseases (e.g., glaucoma). In this study, we combined magnetic resonance imaging (MRI) and mathematical modeling to investigate this potential ONSAS collapse and its effects on the TLCPD. METHODS: First, we performed MRI on six healthy volunteers in 6° head-down tilt (HDT) and 13° head-up tilt (HUT) to assess changes in ONSAS volume (measured from the eye to the optic canal) with changes in posture. The volume change reflects optic nerve sheath (ONS) distensibility. Second, we used the MRI data and mathematical modeling to simulate ONSAS pressure and the potential ONSAS collapse in a 90° upright posture. RESULTS: The MRI showed a 33% decrease in ONSAS volume from the HDT to HUT (P < 0.001). In the upright posture, the simulations predicted an ONSAS collapse 25 mm behind lamina cribrosa, disrupting the pressure communication between the ONSAS and the intracranial subarachnoid space. The collapse reduced the simulated postural increase in TLCPD by roughly 1 mm Hg, although this reduction was highly sensitive to ONS distensibility, varying between 0 and 4.8 mm Hg when varying the distensibility by ± 1 SD. CONCLUSIONS: The ONSAS volume along the optic nerve is posture dependent. The simulations supported the hypothesized ONSAS collapse in the upright posture and showed that even small changes in ONS stiffness/distensibility may affect the TLCPD.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Holmlund P, Støverud KH, Wåhlin A, et al. Posture-Dependent Collapse of the Optic Nerve Subarachnoid Space: A Combined MRI and Modeling Study. Invest Ophthalmol Vis Sci. 2021. PMID: 33877263. doi:10.1167/iovs.62.4.26

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。