诊所内非专家眼底照片筛查眼病的诊断效度与检出率
本研究在糖尿病、甲状腺和普通内科诊所对≥50岁患者进行视力、眼压和眼底照相筛查,由非眼科人员在筛查点判读照片。眼底照相筛查糖尿病视网膜病变灵敏度67%,视力筛查白内障灵敏度89%,眼压筛查青光眼或疑似青光眼灵敏度25%;三个诊所眼病负担均较高。
要点
- 非眼科人员判读眼底照片筛查糖尿病视网膜病变灵敏度67%。
- 视力筛查白内障灵敏度89%,眼压筛查青光眼或疑似青光眼灵敏度25%。
- 三个诊所中至少一种目标眼病检出率分别为25%、34%和21%。
核心结论
- 在资源有限环境下,由非眼科人员在诊所内进行眼病筛查可能是检测眼病的有用模式。
研究设计与样本
- 诊断准确性研究,纳入糖尿病、甲状腺和普通内科诊所的≥50岁患者,共889例入组。
- 筛查采用视力、眼压和眼底照相,照片由非眼科人员在筛查点判读。
- 筛查阳性者及10%随机阴性样本转诊接受眼科参考标准检查。
主要发现
- 889例参与者中229例至少一项筛查阳性,其中189例接受眼科检查;另76例筛查完全正常者转诊,其中50例接受检查。
- 眼底照相筛查糖尿病视网膜病变灵敏度67%(95%CI 39%-87%)。
- 视力筛查白内障灵敏度89%(95%CI 86%-92%)。
- 眼压筛查青光眼或疑似青光眼灵敏度25%(95%CI 14%-40%)。
- 至少一种目标眼病(AMD、DR、青光眼或疑似青光眼、白内障)检出率:糖尿病诊所25%(95%CI 17%-35%),甲状腺诊所34%(95%CI 22%-49%),普通诊所21%(95%CI 13%-32%)。
关键数值与推荐
- 糖尿病视网膜病变筛查采用眼底照相,灵敏度67%(95%CI 39%-87%)。
- 白内障筛查采用视力检查,灵敏度89%(95%CI 86%-92%)。
- 青光眼或疑似青光眼筛查采用眼压测量,灵敏度25%(95%CI 14%-40%)。
临床怎么用
- 可在资源有限诊所由非眼科人员使用眼底照相、视力和眼压进行眼病筛查。
- 筛查阳性者应转诊眼科进行参考标准检查以确诊。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: The intent of this study was to determine the diagnostic accuracy of several diagnostic tests for age-related macular degeneration (AMD), diabetic retinopathy (DR), glaucoma, and cataract, as well as the proportions of patients with eye disease from each of 3 enrolling clinics. DESIGN: Diagnostic accuracy study. METHODS: Patients ≥50 years old in a diabetes, thyroid, and general medicine clinic were screened using visual acuity, tonometry, and fundus photography. Photographs were graded at the point-of-screening by non-ophthalmic personnel. Participants with positive screening test results in either eye and a 10% random sample with negative results in both eyes were referred for an in-person, reference-standard ophthalmology examination. RESULTS: Of 889 participants enrolled, 229 participants failed at least 1 test in either eye, of which 189 presented for an ophthalmic examination. An additional 76 participants with completely normal screening test results were referred for examination, of which 50 attended. Fundus photography screening had the highest yield for DR (sensitivity: 67%; 95% confidence interval [CI]: 39%-87%), visual acuity screening for cataract (sensitivity: 89%; 95% CI: 86%-92%), and intraocular pressure screening for glaucoma or suspected glaucoma (sensitivity: 25%; 95% CI: 14%-40%). The burden of disease was relatively high in all 3 clinics, with at least 1 of the diseases of interest (ie, AMD, DR, glaucoma or suspected glaucoma, or cataract) detected in 25% of participants (95% CI: 17-35%) from the diabeteses clinic, 34% (95% CI: 22%-49%) from the thyroid clinic, and 21% (95% CI: 13%-32%) from the general clinic. CONCLUSIONS: Non-expert eye disease screening in health clinics may be a useful model for detection of eye disease in resource-limited settings.
引用
- Ausayakhun S, Snyder BM, Ausayakhun S, et al. Clinic-Based Eye Disease Screening Using Non-Expert Fundus Photo Graders at the Point of Screening: Diagnostic Validity and Yield. Am J Ophthalmol. 2021. PMID: 33823160. doi:10.1016/j.ajo.2021.03.029
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。