文献速递角膜与眼表疾病

唾液流率测量在小唾液腺自体移植治疗重度干眼中的应用

Use of saliva flow rate measurement in minor salivary glands autotransplantation for treatment of severe dry eye disease.
PubMed 文献 · Br J Ophthalmol · 2021-03-05

研究对18眼(17例)重度干眼患者行小唾液腺自体移植,术前测量小唾液腺流率(MSGFR)并据以选择供区。术后移植物均存活,症状总体缓解率58.8%,Schirmer试验值从0 mm增至4 mm(p<0.05)。术前MSGFR对术后症状缓解有优秀判别力(AUC=0.948,p<0.01),切点1.785 µL/min/cm2时敏感度100%、特异度72.7%。

要点

  • 术前MSGFR可预测小唾液腺自体移植术后干眼症状缓解,AUC=0.948。
  • 切点1.785 µL/min/cm2时敏感度100%、特异度72.7%。
  • 术前MSGFR>1.785 µL/min/cm2者术后Schirmer改善优于≤1.785者(p<0.05)。

核心结论

  • 小唾液腺移植对重度干眼治疗有用,术后润滑量与疗效同术前MSGFR正相关。
  • MSGFR测量与供区选择应作为术前关键步骤。

研究设计与样本

  • 对18眼(17例)重度干眼患者行小唾液腺自体移植,术前测量MSGFR并选择流率较高的一侧上下唇为供区。
  • 唇部小唾液腺MSGFR明显降低时以颊黏膜作为备选供区。
  • 取两片带覆盖黏膜的唾液腺小叶移植至上下睑受床。

主要发现

  • 供区为下唇12眼、上唇5眼、颊黏膜1眼,术后随访确认所有病例移植物存活。
  • 干眼症状总体主观缓解率为58.8%,Schirmer试验值从0 mm增至4 mm(p<0.05)。
  • 术前MSGFR均值为1.7(范围0.9-3.3)µL/min/cm2。
  • ROC分析示术前MSGFR预测术后症状缓解的AUC=0.948(p<0.01)。
  • 术前MSGFR>1.785 µL/min/cm2者术后Schirmer试验值改善大于≤1.785 µL/min/cm2者(p<0.05)。

关键数值与推荐

  • 术前MSGFR切点1.785 µL/min/cm2对应最大敏感度100%与特异度72.7%。

临床怎么用

  • 重度干眼行小唾液腺自体移植前应测量MSGFR,并优先选择MSGFR较高侧唇部作为供区。
  • 唇部小唾液腺MSGFR明显降低时可考虑颊黏膜作为备选供区。
  • 术前MSGFR>1.785 µL/min/cm2的患者可能获得更好的术后Schirmer改善。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: To use minor salivary glands' flow rate (MSGFR) measurement in minor salivary glands (MSGs) autotransplantation for the treatment of severe dry eye disease (DED). METHODS: MSGs autotransplantations were performed in 18 eyes (17 patients) with severe DED. MSGFR were measured before operation. The upper or lower lip with higher MSGFR was selected as the donor site. Buccal mucosa was the back-up in cases labial MSGs showing markedly decreased MSGFRs. Two pieces of salivary lobules with the covering mucosa were harvested and transplanted to the recipient beds prepared in both upper and lower lids. RESULTS: The donor sites included lower lip in 12 eyes, upper lip in 5 eyes and buccal mucosa in 1 eye. Postoperative follow-up confirmed viable grafts in all cases. The overall subjective relief rate of DED symptoms was 58.8%, with Schirmer test values increasing from 0 mm to 4 mm (p<0.05). The mean preoperative MSGFR was 1.7 (range: 0.9-3.3) µL/min/cm2. ROC analysis indicated an outstanding discrimination power for preoperative MSGFR to predicate postoperative relief of DED symptoms (area under the curve (AUC)=0.948, p<0.01). The maximum sensitivity (100%) and specificity (72.7%) were reached at a cut-off of 1.785 µL/min/cm2. Patients with preoperative MSGFR >1.785 µL/min/cm2 showed greater improvement of Schirmer test values after surgery than those with MSGFR ≤1.785 µL/min/cm2 (p<0.05). CONCLUSION: MSGs transplantation proved to be useful for treating severe DED. The amount of postoperative lubrication and the treatment effect were positively correlated with preoperative MSGFR. MSGFR measurement and donor-site selection should be critical steps before the operation.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Su JZ, Wang Z, Liu XJ, et al. Use of saliva flow rate measurement in minor salivary glands autotransplantation for treatment of severe dry eye disease. Br J Ophthalmol. 2021. PMID: 33674426. doi:10.1136/bjophthalmol-2020-317552

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。