人类青光眼眼视网膜神经节细胞形态的定量分析
本研究采用自适应光学-光学相干断层扫描(AO-OCT)对6例伴有半视野缺损的原发性开角型青光眼患者和6例年龄匹配健康对照的黄斑区六个位置进行在体视网膜神经节细胞(RGC)成像。结果显示青光眼患者神经节细胞层(GCL)胞体密度和对称性降低、胞体尺寸增大,且形态学改变与半视野缺损对应,细胞水平结构丢失与视功能损失相关。
要点
- 青光眼患者黄斑区GCL胞体密度在3°、6°、12°均显著低于健康对照。
- 青光眼患者GCL胞体平均直径显著大于对照,对称性显著降低。
- RGC形态学改变与半视野缺损对应,并与视功能损失相关。
核心结论
- 青光眼患者GCL胞体密度和对称性降低、胞体尺寸增大,形态学改变与半视野缺损对应,细胞水平结构丢失与视功能损失相关。
- 基于AO的形态学参数可能成为青光眼的敏感生物标志物。
研究设计与样本
- 研究纳入6例平均年龄58岁的早至中度原发性开角型青光眼伴半视野缺损患者和6例平均年龄61岁的年龄匹配健康对照。
- 所有参与者接受AO-OCT在黄斑区六个主要位置进行在体RGC成像,手动计数GCL胞体并计算密度、尺寸和对称性等形态学参数。
- RGC细胞特征与功能性视野测量进行相关性分析。
主要发现
- 青光眼患者GCL胞体密度在3°、6°、12°分别为12,799 ± 7747 cells/mm2、9370 ± 5572 cells/mm2、2134 ± 1494 cells/mm2,健康对照相应位置分别为25,058 ± 4649 cells/mm2、15,551 ± 2301 cells/mm2、3891 ± 1105 cells/mm2(所有位置P < 0.05)。
- 青光眼患者平均胞体直径为14.20 ± 2.30 µm,显著大于健康对照的12.32 ± 1.94 µm(所有位置P < 0.05)。
- 青光眼组和对照组的对称性分别为0.36 ± 0.32和0.86 ± 0.13。
临床怎么用
- AO-OCT可定量评估GCL胞体密度、尺寸和对称性,作为青光眼细胞水平结构损伤的潜在影像标志物。
- RGC形态学参数与视野缺损对应,可用于关联结构与功能评估。
局限性
- 样本量小(青光眼和对照组各6例),结论需更大样本验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To characterize retinal ganglion cell morphological changes in patients with primary open-angle glaucoma associated with hemifield defect (HD) using adaptive optics-optical coherence tomography (AO-OCT). METHODS: Six patients with early to moderate primary open-angle glaucoma with an average age of 58 years associated with HD and six age-matched healthy controls with an average age of 61 years were included. All participants underwent in vivo retinal ganglion cell (RGC) imaging at six primary locations across the macula with AO-OCT. Ganglion cell layer (GCL) somas were manually counted, and morphological parameters of GCL soma density, size, and symmetry were calculated. RGC cellular characteristics were correlated with functional visual field measurements. RESULTS: GCL soma density was 12,799 ± 7747 cells/mm2, 9370 ± 5572 cells/mm2, and 2134 ± 1494 cells/mm2 at 3°, 6°, and 12°, respectively, in glaucoma patients compared with 25,058 ± 4649 cells/mm2, 15,551 ± 2301 cells/mm2, and 3891 ± 1105 cells/mm2 (P < 0.05 for all locations) at the corresponding retinal locations in healthy participants. Mean soma diameter was significantly larger in glaucoma patients (14.20 ± 2.30 µm) compared with the health controls (12.32 ± 1.94 µm, P < 0.05 for all locations); symmetry was 0.36 ± 0.32 and 0.86 ± 0.13 in glaucoma and control cohorts, respectively. CONCLUSIONS: Glaucoma patients had lower GCL soma density and symmetry, greater soma size, and increased variation of GCL soma reflectance compared with age-matched control subjects. The morphological changes corresponded with HD, and the cellular level structural loss correlated with visual function loss in glaucoma. AO-based morphological parameters could be potential sensitive biomarkers for glaucoma.
引用
- Liu Z, Saeedi O, Zhang F, et al. Quantification of Retinal Ganglion Cell Morphology in Human Glaucomatous Eyes. Invest Ophthalmol Vis Sci. 2021. PMID: 33760041. doi:10.1167/iovs.62.3.34
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。