文献速递眼底病与葡萄膜炎

Spectralis与Cirrus OCT检测视网膜色素上皮及外层视网膜萎缩的比较

COMPARISON OF SPECTRALIS AND CIRRUS OPTICAL COHERENCE TOMOGRAPHY FOR THE DETECTION OF INCOMPLETE AND COMPLETE RETINAL PIGMENT EPITHELIUM AND OUTER RETINAL ATROPHY.
PubMed 文献 · Retina · 2021-01-01

本研究对晚期年龄相关性黄斑变性受试者同日使用Spectralis和Cirrus OCT成像,由两名盲法独立视网膜专家评估iRORA和cRORA病变。结果显示Spectralis检测到的iRORA病变数量显著多于Cirrus,而cRORA病变数量无显著差异;两种设备对cRORA的一致性极好,对iRORA一致性良好。

要点

  • Spectralis检测到的iRORA病变数量显著多于Cirrus。
  • 两种设备检测cRORA病变数量无显著差异。
  • 设备间cRORA一致性极好,iRORA一致性良好。

核心结论

  • Spectralis和Cirrus OCT检测到的cRORA病变数量相似,但Spectralis可检测到更多iRORA病变。

研究设计与样本

  • 研究纳入晚期年龄相关性黄斑变性受试者,同日使用Spectralis和Cirrus OCT成像。
  • 两名盲法独立且经验丰富的视网膜专家评估每个病例的cRORA和iRORA病变。

主要发现

  • Spectralis检测到的病变总数显著高于Cirrus(239 vs. 226 和 223 vs. 209)。
  • Spectralis检测到的iRORA病变数量更多(105 vs. 90 和 96 vs. 82)。
  • 两种设备检测到的cRORA病变数量无显著差异(134 vs. 136 和 128 vs. 126)。
  • 两位评估者中,设备间对cRORA存在与否的一致性极好,对iRORA的一致性良好。

临床怎么用

  • 研究结果可能影响基于预期萎缩靶点制定试验的采集方案。
  • 强调在研究中使用一致的OCT仪器的重要性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate and compare the detection of incomplete and complete retinal pigment epithelial and outer retinal atrophy (iRORA and cRORA) using Spectralis and Cirrus optical coherence tomography (OCT) devices. METHODS: Subjects with late age-related macular degeneration were imaged on the same day with Spectralis and Cirrus OCT. Two, masked, independent, and experienced retina specialist graders evaluated each case for the presence of cRORA and iRORA lesions. RESULTS: A significantly higher number of lesions were observed using Spectralis compared with Cirrus (239 vs. 226 and 223 vs. 209). Higher number of iRORA lesions were identified with Spectralis (105 vs. 90 and 96 vs. 82), and no significant difference was observed between devices for cRORA lesions (134 vs. 136 and 128 vs. 126). When considering the presence or absence of iRORA or cRORA, the agreement between devices for both graders was excellent for cRORA and good for iRORA. CONCLUSION: Spectralis and Cirrus OCT identified a similar number of cRORA lesions, although more iRORA lesions could be detected with Spectralis OCT. These findings may have implications for developing acquisition protocols for trials based on the intended atrophy targets and highlight the importance of using a consistent OCT instrument across a study.

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Corvi F, Corradetti G, Nittala MG, et al. COMPARISON OF SPECTRALIS AND CIRRUS OPTICAL COHERENCE TOMOGRAPHY FOR THE DETECTION OF INCOMPLETE AND COMPLETE RETINAL PIGMENT EPITHELIUM AND OUTER RETINAL ATROPHY. Retina. 2021. PMID: 33655896. doi:10.1097/IAE.0000000000003158

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。