眼前节OCT与超声生物显微镜测量角膜及球结膜肿瘤厚度的比较
AS-OCT与UBM测厚显著正相关(p<0.001),UBM与病理测厚显著正相关(p=0.031),AS-OCT与病理仅轻度非显著正相关。结论认为两者均有用,但均不能替代病理金标准。
要点
- AS-OCT与UBM测厚显著正相关(p<0.001),UBM与病理测厚显著正相关(p=0.031)。
- AS-OCT与病理测厚仅轻度非显著正相关。
- AS-OCT细节优于UBM,但对恶性肿瘤后边界显示受限。
核心结论
- AS-OCT和UBM均可用于角膜及球结膜肿瘤的成像与厚度测量。
- AS-OCT细节优于UBM,但在显示肿瘤后边界方面更受限,尤其在恶性肿瘤中。
- 两种方法的厚度测量虽相关,但均不应被视为组织病理学金标准的替代。
研究设计与样本
- 统计分析病理与AS-OCT及UBM测厚的相关性;未切除病例比较AS-OCT与UBM测厚。
主要发现
- AS-OCT与UBM测厚呈显著正相关(p=<0.001)。
- UBM与病理测厚呈显著正相关(p=0.031)。
- 病理与AS-OCT测厚仅呈轻度但非显著正相关。
关键数值与推荐
- AS-OCT与UBM测厚相关性p=<0.001。
- UBM与病理测厚相关性p=0.031。
- AS-OCT与病理测厚相关性为轻度但非显著。
临床怎么用
- 可用AS-OCT和UBM无创评估角膜及球结膜肿瘤厚度,但需知两者均不能替代病理测厚。
- 对怀疑恶性肿瘤者,AS-OCT显示肿瘤后边界可能受限,应结合其他评估。
局限性
- 原文未报告AS-OCT与病理、UBM与病理相关性的具体相关系数及置信区间。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND/OBJECTIVE: Anterior segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM) are two non-invasive imaging techniques used for the measurement of tumour thickness in corneal and bulbar conjunctival tumours. Histopathology (HP), however, remains the gold standard for the measurement of tumour thickness. The aim of this study was to determine whether AS-OCT and UBM are as accurate as HP for measuring tumour thickness. METHODS: Forty-two corneal and bulbar conjunctival tumours were imaged using AS-OCT and UBM. Images were assessed and tumour thickness was measured. Eleven patients subsequently underwent surgical excision. All specimens were measured during histopathological analysis. The correlation of the thickness measurement on HP to AS-OCT and UBM was then statistically analysed. In cases where the tumour was not excised, thickness measurement comparisons between AS-OCT and UBM were analysed. RESULTS: AS-OCT and UBM measurements of tumour thickness were found to be significantly positively correlated (p=<0.001), as were UBM and HP thickness measurements (p=0.031). HP and AS-OCT measurements, however, only showed a mild but non-significant positive correlation. CONCLUSION: Both AS-OCT and UBM are useful techniques to image and measure the thickness of corneal and conjunctival bulbar tumours. While AS-OCT provides better details than UBM, it was more limited in visualising the posterior boundary of the tumour, particularly in malignant tumours. While thickness measurements of both methodologies were correlated, neither should yet be considered as replacements to the gold standard of HP.
引用
- Lauwers N, Janssens K, Mertens M, et al. Anterior segment optical coherence tomography and ultrasound biomicroscopy for measuring thickness of corneal and bulbar conjunctival tumours. Br J Ophthalmol. 2021. PMID: 33547035. doi:10.1136/bjophthalmol-2018-312337
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。