文献速递角膜与眼表疾病

对比竞争范式揭示圆锥角膜单眼输入抑制

Contrast Rivalry Paradigm Reveals Suppression of Monocular Input in Keratoconus.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2021-01-01

研究用双眼对比竞争范式量化50例圆锥角膜患者(11-31岁)和12名年龄匹配对照的单眼抑制深度,发现病情较轻眼在双眼竞争中占优势,抑制深度与双眼疾病严重程度差异、光学矫正方式和刺激空间频率相关。

要点

  • 圆锥角膜患者中病情较轻眼在双眼视觉中占优势。
  • 较差眼的抑制深度与双眼疾病严重程度差异强相关(r=0.83)。
  • 抑制深度在低空间频率和硬性透气性接触镜下降低。

核心结论

  • 圆锥角膜中病情较轻眼主导双眼视觉,较差眼的抑制深度取决于双眼疾病严重程度、光学矫正方式和目标空间频率。

研究设计与样本

  • 在50例圆锥角膜患者(11-31岁)和12名年龄匹配对照中,通过双眼分视正交Gabor斑块(5 cpd和1.5 cpd空间频率)诱导对比竞争120秒,分别在最佳矫正眼镜和硬性透气性接触镜下进行。

主要发现

  • 基线5 cpd眼镜矫正下,病例组的竞争切换频率更低且偏向较强眼,均相对于对照(P < 0.001)。
  • 病例组的对比平衡点(20.51% [10.7-61%])低于对照组(99.80% [98.6-100%];P < 0.001),且与整体及眼间疾病严重程度差异强相关(r = 0.83,P < 0.001)。
  • 1.5 cpd刺激下抑制深度(70.8% [21.7-94%])较5 cpd降低(P < 0.001);接触镜下(80.1% [49.5-91.7%])较眼镜下降低(P < 0.001)。

关键数值与推荐

  • 对比平衡点:病例组20.51% [10.7-61%],对照组99.80% [98.6-100%](P < 0.001)。
  • 抑制深度与疾病严重程度差异的相关系数r = 0.83(P < 0.001)。
  • 1.5 cpd刺激下抑制深度70.8% [21.7-94%],5 cpd下相应值未报告。
  • 接触镜下抑制深度80.1% [49.5-91.7%],眼镜下相应值未报告。

临床怎么用

  • 圆锥角膜患者双眼视觉评估需考虑抑制效应,病情较轻眼可能主导双眼视觉。
  • 光学矫正方式(眼镜 vs 接触镜)和刺激空间频率可影响抑制深度测量。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Keratoconus results in image quality loss in one or both eyes due to increased corneal distortion. This study quantified the depth of monocular suppression in keratoconus due to this image quality loss using a binocular contrast rivalry paradigm. METHODS: Contrast rivalry was induced in 50 keratoconic cases (11-31 years) and 12 age-matched controls by dichoptically viewing orthogonal Gabor patches of 5 cycles per degree (cpd) and 1.5 cpd spatial frequency for 120 seconds with their best-corrected spectacles and rigid gas permeable (RGP) contact lenses. The dwell time on each eye's percept was determined at baseline (100% contrast bilaterally) and at varying contrast levels (80-2.5%) in the stronger eye of keratoconus or dominant eye of controls. The contrast reduction needed in the stronger eye to balance dwell times on both eyes was considered a measure of suppression depth. RESULTS: At baseline with 5 cpd stimuli and spectacle correction, the rivalry switches were less frequent and biased toward the stronger eye of cases, all relative to controls (P < 0.001). The contrast balance point of cases (20.51% [10.7-61%]) was lower than the controls (99.80% [98.6-100%]; P < 0.001) and strongly associated with the overall and interocular difference in disease severity (r = 0.83, P < 0.001). The suppression depth reduced for 1.5 cpd (70.8% [21.7-94%]), relative to 5 cpd stimulus (P < 0.001) and with contact lenses (80.1% [49.5-91.7%]), relative to spectacles (P < 0.001). CONCLUSIONS: The eye with lesser disease severity dominates binocular viewing in keratoconus. The suppression depth of the poorer eye depends on the extent of bilateral disease severity, optical correction modality, and the target spatial frequency.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Marella BL, Conway ML, Suttle C, et al. Contrast Rivalry Paradigm Reveals Suppression of Monocular Input in Keratoconus. Invest Ophthalmol Vis Sci. 2021. PMID: 33570601. doi:10.1167/iovs.62.2.12

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。