SMILE术后角膜生物力学变化与术中切削厚度的关系
该回顾性研究纳入184例(184只右眼)行SMILE的患者,分析术后3个月角膜生物力学参数变化与残余基质厚度(RST)及组织去除厚度百分比(PTA)的关系。结果显示DA ratio、SPA1和IR的变化量随RST减少或PTA增加而升高,当RST<280 μm或PTA>28%时DA ratio变化曲线斜率明显增加;术前角膜生物力学参数和术后中央角膜厚度(CCT)是术后生物力学特性的主要影响因素。
要点
- SMILE术后DA ratio、SPA1和IR变化量随RST减少或PTA增加而升高。
- 当RST<280 μm或PTA>28%时,DA ratio变化曲线斜率明显增加。
- 术前生物力学参数和术后CCT是术后生物力学特性的主要影响因素。
核心结论
- SMILE术后DA ratio、SPA1和IR的改变随RST减少或PTA增加而增加,当RST<280 μm或PTA>28%时DA ratio改变速度明显加快。
- 术前角膜生物力学特性和术后CCT是影响术后角膜生物力学稳定性的主要因素。
研究设计与样本
- 回顾性系列病例研究,纳入2019年1月至2020年1月于天津市眼科医院屈光手术中心行SMILE者184例(184只右眼),男83例、女101例,年龄(24.6±5.8)岁。
- 于术前和术后3个月用Corvis ST测量DA ratio、SPA1和IR,对RST、PTA与参数变化量的关系进行线性和非线性回归分析。
- 以年龄、性别、角膜前表面平均曲率、术前等效球镜度数、术后CCT和术前生物力学参数为自变量,采用步进法多元线性回归分析术后参数的影响因素。
主要发现
- SMILE术后DA ratio、SPA1和IR的变化量(变化率)分别为1.33(30.0%)、28.05(26.0%)和2.56(34.0%),手术前后差异均有统计学意义(t=35.52、-28.00、36.95,P<0.01)。
- 最优拟合曲线显示,随着RST减少或PTA增加,DA ratio、SPA1和IR的变化量逐渐升高。
- 当RST<280 μm或PTA>28%时,DA ratio变化量曲线斜率明显增加。
- 多因素回归模型显示,对术后DA ratio、SPA1和IR影响权重最大的因素分别为术前DA ratio(Sβ=0.489)、术前SPA1(Sβ=0.483)和术前IR(Sβ=0.471)。
- CCT是术后DA ratio和SPA1的第二大影响因素(Sβ=-0.238,0.326)。
关键数值与推荐
- 当RST<280 μm或PTA>28%时,DA ratio变化量曲线斜率明显增加。
- 术后DA ratio、SPA1和IR的变化量(变化率)分别为1.33(30.0%)、28.05(26.0%)和2.56(34.0%)。
- 术前DA ratio、术前SPA1和术前IR的标准化回归系数分别为Sβ=0.489、0.483和0.471。
- CCT对术后DA ratio和SPA1的标准化回归系数分别为Sβ=-0.238和0.326。
临床怎么用
- SMILE术前规划切削厚度时,可关注RST和PTA,当RST<280 μm或PTA>28%时DA ratio变化加快。
- 术前角膜生物力学参数和术后CCT可用于预估SMILE术后角膜生物力学特性变化。
局限性
- 本研究为回顾性研究,仅纳入184只右眼,随访时间为术后3个月。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Objective: To explore the rule of corneal biomechanical alteration with residual stromal thickness (RST) and percent tissue altered (PTA) after small incision lenticule extraction (SMILE) and to determine the factors influencing postoperative corneal biomechanical properties. Methods: In this retrospective study, a total of 184 patients (184 right eyes) who underwent SMILE in Tianjin Eye Hospital Refractive Surgery Center from January 2019 to January 2020 were enrolled. There were 83 males and 101 females with age of (24.6±5.8) years. Corneal biomechanical parameters, including DA ratio, stiffness parameter at the first applanation (SPA1) and integrated radius (IR), were measured with Corvis ST preoperatively and at 3 months postoperatively. The association between PTA, RST and the changes of DA ratio, SPA1 and IR was assessed by linear and nonlinear regression analyses. Stepwise multivariate regression analyses were conducted to explore the factors associated with postoperative corneal biomechanical parameters with age, sex, anterior mean keratometry, spherical equivalent, postoperative central corneal thickness (CCT) and preoperative corneal biomechanical parameters as covariates. Preoperative and postoperative data were compared using the paired t test. Correlations were determined by the Pearson or Spearman analysis. Results: The alterations at 3 months postoperatively of DA ratio, SPA1 and IR were 1.33 (30.0%), 28.05 (26.0%) and 2.56 (34.0%), respectively. The changes before and after surgery were statistically significant (t=35.52, -28.00, 36.95, P<0.01). The best-fit curve showed that the changes of DA ratio, SPA1 and IR increased with the decrease of RST or increase of PTA. When the RST was<280 μm or the PTA was>28%, the slope of the change of DA ratio curve was significantly increased. Multivariate regression models showed that the factors with the greatest influence on postoperative DA ratio, SPA1 and IR were preoperative DA ratio (Sβ=0.489, P<0.01), preoperative SPA1 (Sβ=0.483, P<0.01) and preoperative IR (Sβ=0.471, P<0.01), respectively. The CCT was the second factor that influenced postoperative DA ratio and SPA1 (Sβ=-0.238, P<0.01; Sβ=0.326, P<0.01). Conclusions: The changes of DA ratio, SPA1 and IR following SMILE increased with the decrease of RST or increase of PTA. With the RST<280 μm or the PTA>28%, the alteration of DA ratio significantly accelerated. Preoperative corneal biomechanical properties and postoperative CCT were main factors influencing corneal biomechanical properties after SMILE. (Chin J Ophthalmol, 2021, 57: 104-112). 目的: 探讨飞秒激光小切口角膜基质透镜取出术(SMILE)后角膜生物力学特性变化量随残余基质厚度(RST)、组织去除厚度百分比(PTA)的变化规律,并分析SMILE后角膜生物力学特性的影响因素。 方法: 回顾性系列病例研究。选取2019年1月至2020年1月于天津市眼科医院屈光手术中心行SMILE者184例(184只右眼),其中男性83例,女性101例,年龄(24.6±5.8)岁。于术前和术后3个月用Corvis ST角膜生物力学分析仪测量术眼的角膜生物力学参数,包括形变幅度比值(DA ratio)、角膜硬度参数(SPA1)和综合半径(IR)。对RST、PAT与DA ratio、SPA1、IR的变化量的关系进行线性和非线性回归分析。纳入年龄、性别、角膜前表面平均曲率(Km)、术前等效球镜度数(SE)、术后角膜中央厚度(CCT)和术前角膜生物力学参数为自变量,采用步进法多元线性回归模型分析术后DA ratio、SPA1和IR的影响因素。对手术前后数据比较采用配对t检验;相关性检验采用Pearson或Spearman相关性分析。 结果: SMILE术后DA ratio、SPA1和IR的变化量(变化率)分别为1.33(30.0%)、28.05(26.0%)和2.56(34.0%),手术前后差异均具有统计学意义(t=35.52, -28.00, 36.95;P<0.01)。最优拟合曲线显示,随着RST减少或者PTA的增加,DA ratio、SPA1和IR的变化量逐渐升高。其中,当RST<280 μm或者PTA>28%时,DA ratio变化量曲线斜率明显增加。多因素回归模型显示,对SMILE术后DA ratio、SPA1和IR根据标准化回归系数(Sβ值)排序,影响权重前3位的因素分别为术前DA ratio(Sβ=0.489)、术前SPA1(Sβ=0.483)和术前IR(Sβ=0.471);CCT是术后DA ratio和SPA1的第二大影响因素(Sβ=-0.238,0.326)。 结论: SMILE术后DA ratio、SPA1和IR的改变随RST的减少或者PTA的增加而增加,当RST<280 μm或PTA>28%时,DA ratio的改变速度明显加快;术前角膜生物力学特性和术后CCT是影响术后角膜生物力学稳定性的主要因素。(中华眼科杂志,2021,57:104-112).
引用
- Liu J, Wang Y, Zou HH, et al. [Relation between corneal biomechanical alteration after small incision lenticule extraction and intraoperative cutting thickness]. Zhonghua Yan Ke Za Zhi. 2021. PMID: 33541051. doi:10.3760/cma.j.cn112142-20200630-00436
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。