文献速递青光眼

急性原发性闭角型青光眼患者体位相关眼压变化

Posture-Related Changes of Intraocular Pressure in Patients With Acute Primary Angle Closure.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2021-01-01

测量坐位、仰卧位及侧卧位5分钟后眼压,发现APAC眼侧卧位-坐位眼压升高幅度显著大于对侧眼和非急性病眼,且与房角结构狭窄及晶状体拱高增加相关。

要点

  • APAC眼侧卧位-坐位眼压升高(5.7±2.7 mmHg)显著大于对侧眼(2.2±1.4 mmHg)和非急性病眼(3.6±2.0 mmHg)。
  • 晶状体拱高夸张眼在APAC组侧卧位-坐位眼压变化更大(6.3±2.6 vs. 3.9±2.1 mmHg,P=0.011)。
  • APAC组侧卧位-坐位眼压变化与AOD750独立负相关(beta=-8.36,P=0.014)。

核心结论

  • APAC眼存在显著的体位相关眼压变化,且与更窄的房角结构和夸张的晶状体拱高相关。

主要发现

  • APAC眼侧卧位-坐位眼压升高5.7±2.7 mmHg,大于对侧眼2.2±1.4 mmHg(P<0.001)和非急性PACD眼3.6±2.0 mmHg(P<0.001)。
  • 夸张晶状体拱高眼侧卧位-坐位眼压变化大于无此特征眼(APAC组:6.3±2.6 vs. 3.9±2.1 mmHg,P=0.011)。
  • 线性回归显示APAC组侧卧位-坐位眼压变化与AOD、TISA、巩膜突角度及ACD1000负相关;多变量逐步回归中AOD750仍显著(beta=-8.36,P=0.014)。

关键数值与推荐

  • APAC眼侧卧位-坐位眼压升高5.7±2.7 mmHg,对侧眼2.2±1.4 mmHg,非急性PACD眼3.6±2.0 mmHg。
  • 夸张晶状体拱高眼APAC组侧卧位-坐位眼压变化6.3±2.6 mmHg,无此特征眼3.9±2.1 mmHg(P=0.011)。
  • 多变量逐步回归中AOD750与侧卧位-坐位眼压变化独立相关(beta=-8.36,P=0.014)。

临床怎么用

  • 对APAC患者应关注体位改变(尤其侧卧位)引起的眼压升高。
  • 房角狭窄及晶状体拱高夸张的APAC眼体位性眼压波动风险更高。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate the posture-related change in intraocular pressure (IOP) of eyes with angle-closure disease and the associated factors. METHODS: Eyes were prospectively enrolled and divided into three groups: eyes with acute primary angle-closure (APAC), fellow eyes of acute primary angle-closure (FAPAC), and eyes with nonacute primary angle-closure disease (PACD). All of them had been treated with laser peripheral iridotomy. IOP was measured in the sitting, supine, and lateral decubitus positions (LDP) five minutes after posture change. Anterior chamber angle parameters and angle-closure mechanism were evaluated by anterior segment optical coherence tomography. RESULTS: Forty-four eyes were enrolled into each group. APAC eyes showed more LDP-Sitting IOP increase than fellow eyes (5.7 ± 2.7 vs. 2.2 ± 1.4 mm Hg, P < 0.001) and nonacute PACD eyes (3.6 ± 2.0 mm Hg, P < 0.001). LDP-sitting IOP change was higher in eyes with exaggerated lens vault (having shallow anterior chamber and volcano-like iris-lens configuration) than in those without it (APAC: 6.3 ± 2.6 vs. 3.9 ± 2.1 mm Hg, P = 0.011). Linear regression revealed that LDP-sitting IOP change in the APAC group was negatively associated with angle opening distance (AOD), trabecular iris space area, scleral spur angle, and anterior chamber depth (ACD1000). With multivariable stepwise regression analysis, AOD750 remained statistically significant (beta-coefficient = -8.36, P = 0.014). CONCLUSIONS: APAC eyes had significant posture-related IOP changes, associated with narrower angle structures and exaggerated lens vault.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Hsia Y, Su CC, Wang TH, et al. Posture-Related Changes of Intraocular Pressure in Patients With Acute Primary Angle Closure. Invest Ophthalmol Vis Sci. 2021. PMID: 33620375. doi:10.1167/iovs.62.2.37

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。