新冠疫情期间避免面罩相关视野检查伪影
该研究回顾性分析了307份戴口罩完成的视野检查,并与疫情前视野对比,识别出18份(5.8%)疑似因面罩佩戴不当导致假性进展的视野。重新佩戴上缘贴胶带的外科口罩复查后,中位VFI和MD显著改善,与疫情前无显著差异;未贴合口罩时中位固视丢失率显著更高(13% vs 6%,p=0.047)。
要点
- 未贴合面罩可模拟视野进展,发生率约6%,主要累及下半侧视野。
- 未贴合面罩时固视丢失率显著升高(中位13% vs 6%,p=0.047)。
- 外科口罩上缘贴胶带复查可减少面罩相关伪影。
核心结论
- 未贴合的面罩可在约6%的视野检查中模拟视野进展,主要表现为下半侧视野新发暗点或原有缺损扩大,并显著增加固视丢失率。
研究设计与样本
- 回顾性研究,共回顾307份戴口罩(FPP2/KN95或外科口罩)完成的视野检查,并与疫情前视野对比。
主要发现
- 识别出18份(5.8%)疑似因面罩导致假性进展的视野检查。
- 所有疑似病例在调整面罩上缘后复查,中位VFI和MD显著改善,与疫情前检查无显著差异。
- 未贴合面罩时中位固视丢失率显著高于贴合后(13% vs 6%,p=0.047)。
- 下半侧视野最常受累,表现为新发暗点或原有缺损扩大。
- 使用FPP2/KN95口罩与外科口罩的面罩相关伪影发生率相似。
关键数值与推荐
- 疑似面罩伪影的视野检查重复时使用外科口罩并在其上缘贴胶带(VF test 2),以区分真性视野缺损。
- 比较参数包括可靠性指标、检查时长、VFI、MD和模式偏差概率图,采用Wilcoxon符号秩检验。
临床怎么用
- 疫情期间或需戴口罩行视野检查时,应注意未贴合面罩可能导致下半侧视野假性进展和固视丢失增加。
- 对疑似面罩相关伪影的视野,可让患者佩戴上缘贴胶带的外科口罩复查,以辅助鉴别真性进展。
局限性
- 原文未报告
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: To assess visual field (VF) pseudoprogression related to face mask use. METHODS: We reviewed a total of 307 VFs performed with a face mask (FPP2/KN95 or surgical masks) and compared them with prior VFs, performed before the pandemic. VFs with suspected pseudoprogression due to mask artefacts (VF test 1) were repeated with a surgical mask and an adhesive tape on its superior border (VF test 2) to distinguish from true VF loss. Several parameters including reliability indices, test duration, VF index (VFI), mean defect (MD) and pattern deviation probability plots were compared among last pre-COVID VFs, VF tests 1 and VF tests 2, using the Wilcoxon signed-rank test. RESULTS: We identified 18 VFs with suspected progression artefact due to masks (5.8%). In all of them, the median VFI and MD significantly improved after fitting the superior border of the mask, showing no significant differences with pre-COVID tests. The median fixation losses were significantly higher when wearing the unfitted mask (13% vs 6%,p=0.047). The inferior hemifield was the most affected, either as a new scotoma or as an enlargement of a prior defect. CONCLUSION: Unfitted masks can simulate VF progression in around 6% of cases, mainly in the inferior hemifield, and increase significantly the rate of fixation losses. A similar rate of artefacts was observed using FPP2/KN95 or surgical masks. The use of a surgical mask with an adhesive tape covering the superior border may reduce mask-related artefacts, although concomitant progression cannot be ruled out in all cases.
引用
- Gómez Mariscal M, Muñoz-Negrete FJ, Muñoz-Ramón PV, et al. Avoiding mask-related artefacts in visual field tests during the COVID-19 pandemic. Br J Ophthalmol. 2021. PMID: 33597196. doi:10.1136/bjophthalmol-2020-318408
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。