糖尿病黄斑OCTA评估:不同算法比较研究
本研究纳入30例糖尿病视网膜病变患者(30眼)及15名健康对照,评估直方图调整与二值化阈值选择对OCTA定量测量糖尿病黄斑缺血的影响。结果显示全局阈值二值化图像质量优于局部或多步阈值,「中值」滤波最常被评为最佳直方图调整;局部阈值倾向产生更高测量值,全局与局部阈值间OCTA指标差异与糖尿病黄斑水肿存在及信号强度指数值相关。结论指出OCTA定量参数可能显著受黄斑灌注量化策略影响,图像质量与黄斑水肿可显著影响OCTA衍生定量血管测量及全局与局部二值化阈值间差异。
要点
- 全局阈值二值化图像质量优于局部或多步阈值,「中值」滤波最常被评为最佳直方图调整。
- 局部阈值倾向产生更高OCTA测量值,全局与局部阈值差异与黄斑水肿及信号强度指数相关。
- OCTA定量参数显著受量化策略影响,需采用一致策略可靠生成糖尿病视网膜病变患者OCTA指标。
核心结论
- OCTA定量参数可能显著受黄斑灌注量化策略影响,图像质量与黄斑水肿可显著影响OCTA衍生定量血管测量及全局与局部二值化阈值间差异。
研究设计与样本
- 纳入30例糖尿病视网膜病变患者(30眼)进行扫频源OCTA成像,并纳入15名健康对照进行比较。
- 对原始OCTA图像应用既往使用的亮度/对比度变化及二值化阈值,获得并比较不同二值化图像,进行定性与定量比较。
主要发现
- 30眼中15眼存在糖尿病黄斑水肿。
- 定性分级显示全局阈值获得的二值化图像质量优于局部或多步阈值,「中值」滤波最常被评为最佳直方图调整。
- 定量分析中局部阈值倾向产生更高测量指标值,全局与局部阈值间OCTA指标差异与糖尿病黄斑水肿存在及信号强度指数值相关。
- 健康眼与糖尿病视网膜病变眼比较中,OCTA指标差异显著受二值化阈值选择影响。
临床怎么用
- 在糖尿病视网膜病变患者中生成定量OCTA指标时,应采用一致的量化策略以确保可靠性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To assess the impact of histogram adjustments and binarization thresholding selection on quantitative measurements of diabetic macular ischemia using optical coherence tomography angiography (OCTA). METHODS: Patients with diabetic retinopathy (DR) who had swept-source OCTA imaging obtained were enrolled. An additional group of 15 healthy control subjects was included for comparison. Previously used brightness/contrast changes and binarization thresholds were applied to original OCTA images to obtain and compare different binarized images. Qualitative and quantitative comparisons were performed. RESULTS: Thirty patients with DR (30 eyes) were included in the analysis. Fifteen eyes displayed the presence of diabetic macular edema. Qualitative grading revealed that binarized images obtained using a global threshold had better quality compared with local or multistep thresholds. The "median" filter was most frequently graded as the histogram adjustment resulting in binarized images with best quality. In the quantitative analysis, local thresholds tended to generate higher values of measured metrics. Differences in OCTA metrics between global and local thresholds were associated with presence of diabetic macular edema and signal strength index value. In the comparison between healthy and DR eyes, differences in OCTA metrics were significantly affected by binarization threshold selection. CONCLUSION: Quantitative OCTA parameters may be significantly influenced by strategies to quantify macular perfusion. Image quality and presence of macular edema can significantly impact OCTA-derived quantitative vascular measurements and differences between global and local binarization thresholds. These findings highlight the importance of consistent strategies to reliably generate quantitative OCTA metrics in patients with DR.
引用
- Borrelli E, Sacconi R, Parravano M, et al. OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY ASSESSMENT OF THE DIABETIC MACULA: A Comparison Study Among Different Algorithms. Retina. 2021. PMID: 33587426. doi:10.1097/IAE.0000000000003145
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。