地图样萎缩周围外层视网膜管状结构与脉络膜毛细血管血流信号缺陷的相关性
本研究采用扫频源OCTA评估地图样萎缩患眼旁萎缩带与围萎缩带的脉络膜毛细血管血流缺陷,比较有无外层视网膜管状结构(ORT)的差异。结果显示两组旁萎缩带血流缺陷面积百分比均大于围萎缩带,但有ORT眼的两带间差值较小。
要点
- 有ORT眼旁萎缩带与围萎缩带血流缺陷差值(deltaFD)低于无ORT眼。
- 两组旁萎缩带血流缺陷面积百分比均大于围萎缩带。
- ORT可能与地图样萎缩周围脉络膜毛细血管血流缺陷的纵向梯度减小相关。
核心结论
- 在地图样萎缩患眼中,有ORT眼旁萎缩带与围萎缩带之间的血流缺陷减少幅度小于无ORT眼。
- 两组旁萎缩带血流缺陷均多于围萎缩带。
研究设计与样本
- 采用扫频源光学相干断层扫描血管成像(SS-OCTA)获取6×6 mm扫描图像。
- 对脉络膜毛细血管en-face血流与结构图像进行二值化后分析血流信号缺陷(FD)。
- 分析旁萎缩带(紧邻地图样萎缩的500 µm宽带)和围萎缩带(紧邻前者的500 µm宽带)。
主要发现
- 有ORT和无ORT眼旁萎缩带平均FD面积百分比(%FD)均大于围萎缩带。
- 有ORT眼旁萎缩带与围萎缩带%FD差值(deltaFD)均值为1.8477%(95%CI 0.8607-2.8346)。
- 无ORT眼deltaFD均值为4.0018%(95%CI 2.8622-5.1414),高于有ORT眼。
临床怎么用
- 在评估非新生血管性年龄相关性黄斑变性所致地图样萎缩时,可关注ORT与脉络膜毛细血管血流缺陷的空间分布关系。
- OCTA二值化分析旁萎缩带和围萎缩带FD可能有助于理解ORT周围的微循环改变。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate and compare paralesional and perilesional choriocapillaris vascular impairment in eyes with geographic atrophy with and without outer retinal tubulations (ORT). METHODS: Using swept-source optical coherence tomography angiography, 6 × 6 mm scans of eyes with geographic atrophy with and without ORT were acquired. Choriocapillaris en-face flow and structural images were binarized, before flow signal deficit (FD) analysis in the paraatrophy zone (a 500-µm-wide band adjacent to the geographic atrophy) and the periatrophy zone (a 500-µm-wide band adjacent to the latter). RESULTS: Twenty-four eyes of 19 patients with ORT and 18 eyes of 15 patients without ORT were analyzed. With and without ORT, mean percental area of FD (%FD) was greater in para- than in periatrophy zone. The difference of %FD between para- and periatrophy zone (deltaFD) was lower in eyes with ORT (mean 1.8477%, 95% confidence interval 0.8607-2.8346) than without ORT (mean 4.0018%, 95% confidence interval 2.8622-5.1414). CONCLUSION: In eyes with geographic atrophy caused by non-neovascular age-related macular degeneration, smaller reductions in FDs were found between the para- and periatrophy zone in eyes with ORT. In both cohorts, the paraatrophy zone had more FD than the periatrophy zone.
引用
- Haensli C, Sugiura Y, Freund KB, et al. CORRELATION OF OUTER RETINAL TUBULATIONS AND CHORIOCAPILLARIS FLOW SIGNAL DEFICITS SURROUNDING GEOGRAPHIC ATROPHY. Retina. 2021. PMID: 33625113. doi:10.1097/IAE.0000000000003135
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。