文献速递眼底病与葡萄膜炎

黄斑病变且视力良好患者的对比敏感度函数评估

Contrast sensitivity function in patients with macular disease and good visual acuity.
PubMed 文献 · Br J Ophthalmol · 2021-02-03

本研究采用快速对比敏感度函数(qCSF)方法,评估视力≥20/30的黄斑病变眼与健康对照眼的视觉功能。纳入151只黄斑病变眼和93只对照眼,发现黄斑病变与AULCSF及除18 cpd外各空间频率的CS阈值显著降低相关,尤其在低中等空间频率。qCSF方法有望量化常规视力检查未能识别的细微视觉缺陷。

要点

  • 黄斑病变眼即使视力≥20/30,qCSF测得的对比敏感度仍显著低于健康对照眼。
  • CS阈值降低在1.5、3、6 cpd等低中等空间频率最为明显。
  • qCSF可作为量化黄斑病变细微视觉缺陷的临床工具。

核心结论

  • 采用qCSF主动学习方法测量的对比敏感度在视力良好的黄斑病变眼中显著降低。
  • qCSF方法有望量化当前测试方法可能未识别的细微视觉缺陷。

研究设计与样本

  • 纳入黄斑病变(视网膜静脉阻塞、黄斑脱离性视网膜脱离、干性年龄相关性黄斑变性、湿性年龄相关性黄斑变性)且视力≥20/30的患者。
  • qCSF方法使用智能算法测量多个空间频率的对比敏感度函数。
  • 将所有黄斑病变眼合并及各个黄斑病变组分别与健康对照眼比较。
  • 主要结局包括对数CSF曲线下面积(AULCSF)和1至18 cpd的六个CS阈值。

主要发现

  • 共纳入151只黄斑病变眼和93只视力≥20/30的对照眼。
  • 黄斑病变与AULCSF显著降低相关(β:-0.174;p<0.001)。
  • 除18 cpd外,黄斑病变与所有空间频率的CS阈值显著降低相关(β:-0.094至-0.200 log CS,均p<0.01)。
  • CS阈值降低在低中等空间频率(1.5 cpd、3 cpd和6 cpd)最为明显。

关键数值与推荐

  • 黄斑病变组AULCSF的β值为-0.174(p<0.001)。
  • 除18 cpd外,各空间频率CS阈值的β值范围为-0.094至-0.200 log CS(均p<0.01)。
  • CS阈值降低最明显的空间频率为1.5 cpd、3 cpd和6 cpd。

临床怎么用

  • 对于视力良好的黄斑病变患者,可考虑使用qCSF评估对比敏感度以发现常规视力检查未识别的视觉缺陷。
  • qCSF测量的低中等空间频率CS阈值可能有助于监测黄斑病变的视觉功能损害。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Contrast sensitivity function (CSF) may better estimate a patient's visual function compared with visual acuity (VA). Our study evaluates the quick CSF (qCSF) method to measure visual function in eyes with macular disease and good letter acuity. METHODS: Patients with maculopathies (retinal vein occlusion, macula-off retinal detachment, dry age-related macular degeneration and wet age-related macular degeneration) and good letter acuity (VA ≥20/30) were included. The qCSF method uses an intelligent algorithm to measure CSF across multiple spatial frequencies. All maculopathy eyes combined and individual macular disease groups were compared with healthy control eyes. Main outcomes included area under the log CSF (AULCSF) and six CS thresholds ranging from 1 cycle per degree (cpd) to 18 cpd. RESULTS: 151 eyes with maculopathy and 93 control eyes with VA ≥20/30 were included. The presence of a maculopathy was associated with significant reduction in AULCSF (β: -0.174; p<0.001) and CS thresholds at all spatial frequencies except for 18 cpd (β: -0.094 to -0.200 log CS, all p<0.01) compared with controls. Reductions in CS thresholds were most notable at low and intermediate spatial frequencies (1.5 cpd, 3 cpd and 6 cpd). CONCLUSION: CSF measured with the qCSF active learning method was found to be significantly reduced in eyes affected by macular disease despite good VA compared with healthy control eyes. The qCSF method is a promising clinical tool to quantify subtle visual deficits that may otherwise go unrecognised by current testing methods.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Wai KM, Vingopoulos F, Garg I, et al. Contrast sensitivity function in patients with macular disease and good visual acuity. Br J Ophthalmol. 2021. PMID: 33536229. doi:10.1136/bjophthalmol-2020-318494

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。